Phone +420 774 723 123 Cart · 0 · empty

Pneumatic valves

SMC, Festo and TECHNOLINE pneumatic valves for controlling actuators – 3/2, 5/2 and 5/3 directional valves, base plates for valve terminals and accessories. Choose by function, port, actuation and coil voltage.

Subcategories

Filters
Found 196 products

V111-5LOU, SMC, direct-operated solenoid 3/2 valve, standard version

Cat. no.: V111-5LOU

V111-5LOU, SMC, direct-operated solenoid 3/2 valve, standard version. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

On request
26,63 €
excl. VAT · 32,22 € incl. VAT

VHS20-F01-D, single-stage valve, SMC

Cat. no.: VHS20-F01-D

VHS20-F01-D, single-stage valve, SMC

On request
28,27 €
excl. VAT · 34,20 € incl. VAT

AQ3000-03, SMC, quick exhaust valve

Cat. no.: AQ3000-03

AQ3000-03 SMC – quick exhaust valve. When selecting, verify the connection, size and other parameters of the specific variant.

On request
33,39 €
excl. VAT · 40,40 € incl. VAT

VT307K-4D1-01F-Q, SMC, solenoid 3/2 valve

Cat. no.: VT307K-4D1-01F-Q

VT307K-4D1-01F-Q, SMC, solenoid 3/2 valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
38,09 €
excl. VAT · 46,09 € incl. VAT

VX212EZ3AA, SMC, solenoid valve

Cat. no.: VX212EZ3AA

VX212EZ3AA, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
38,91 €
excl. VAT · 47,08 € incl. VAT

VT307-5DO1-01F-Q, SMC, solenoid valve

Cat. no.: VT307-5DO1-01F-Q

VT307-5DO1-01F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
40,34 €
excl. VAT · 48,82 € incl. VAT

VQ21A1-5YO-C6-F-Q, SMC, solenoid 2/2 valve of series VQ20, 24 V DC, port C6

Cat. no.: VQ21A1-5YO-C6-F-Q

VQ21A1-5YO-C6-F-Q SMC – solenoid 2/2 valve of series VQ20, 24 V DC, port C6. When selecting, verify the connection, size and other parameters of the specific variant.

On request
40,79 €
excl. VAT · 49,36 € incl. VAT

VM132-M5-30BA, SMC, 3/2 valve

Cat. no.: VM132-M5-30BA

VM132-M5-30BA, SMC, 3/2 valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
41,78 €
excl. VAT · 50,55 € incl. VAT

VT307V-5DO1-01F-Q, direct-operated solenoid valve, SMC

Cat. no.: VT307V-5DO1-01F-Q

VT307V-5DO1-01F-Q, direct-operated solenoid valve, SMC

On request
49,14 €
excl. VAT · 59,46 € incl. VAT
OUR TIP

EVT317-5D0-02F-Q, SMC, Pneumatic control valve, 24VDC, G 1/4 3/2

Cat. no.: EVT317-5D0-02F-Q

EVT317-5D0-02F-Q SMC – Pneumatic control valve, 24VDC, G 1/4 3/2. When selecting, verify the connection, size and other parameters of the specific variant.

On request
51,17 €
excl. VAT · 61,91 € incl. VAT

SY3140-5LO-Q, solenoid pilot-operated valve, SMC

Cat. no.: SY3140-5LO-Q

SY3140-5LO-Q, solenoid pilot-operated valve, SMC

On request
51,19 €
excl. VAT · 61,94 € incl. VAT

SY30M-27-1-WO-01F, SMC, base plate for a single SY valve

Cat. no.: SY30M-27-1-WO-01F

SY30M-27-1-WO-01F, SMC, base plate for a single SY valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
52,39 €
excl. VAT · 63,40 € incl. VAT

SYJ514M-5LOU-Q, SMC, solenoid pilot-operated valve

Cat. no.: SYJ514M-5LOU-Q

SYJ514M-5LOU-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
53,03 €
excl. VAT · 64,17 € incl. VAT

SY3140-5LOU-Q, solenoid pilot-operated valve, SMC

Cat. no.: SY3140-5LOU-Q

SY3140-5LOU-Q, solenoid pilot-operated valve, SMC

On request
53,24 €
excl. VAT · 64,42 € incl. VAT

VHS40-F04-M-D, SMC, single-stage valve

Cat. no.: VHS40-F04-M-D

VHS40-F04-M-D, SMC, single-stage valve. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

On request
54,88 €
excl. VAT · 66,40 € incl. VAT

SY5120-5YO-01F-Q, SMC, solenoid valve

Cat. no.: SY5120-5YO-01F-Q

SY5120-5YO-01F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
55,28 €
excl. VAT · 66,89 € incl. VAT

JSY1140T-5LOZ, SMC, solenoid valve

Cat. no.: JSY1140T-5LOZ

JSY1140T-5LOZ, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
55,28 €
excl. VAT · 66,89 € incl. VAT

SY5120-5DO-01F-Q, SMC, solenoid valve

Cat. no.: SY5120-5DO-01F-Q

SY5120-5DO-01F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
55,28 €
excl. VAT · 66,89 € incl. VAT

SYJ522-5LOU-M5-Q, SMC, solenoid 3/2 valve, NO, 24 V DC, M5

Cat. no.: SYJ522-5LOU-M5-Q

SYJ522-5LOU-M5-Q, SMC, solenoid 3/2 valve, NO, 24 V DC, M5. A solenoid valve electrically controls the direction of compressed air flow.

On request
55,45 €
excl. VAT · 67,09 € incl. VAT

EVT317-5DO-02F-Q, SMC, pneumatic control valve

Cat. no.: EVT317-5DO-02F-Q

EVT317-5DO-02F-Q, SMC, pneumatic control valve. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

On request
55,82 €
excl. VAT · 67,54 € incl. VAT

Prices include the recycling fee.

Pneumatic valves

The range includes SMC, Festo and TECHNOLINE pneumatic valves, including the TE3V/TE4V, SY, VQ, VX and VDW series. For selection, it is useful to separate the valve itself, its connection base and electrical accessories.

What the valve actually switches

The designation 5/2 expresses five main ports and two positions; 5/3 adds a third position with a defined connection of channels. The specific Festo VUVG-LK10-M52-AT-M5-1R8L-S is a monostable 5/2 with internal pilot supply. In contrast, VUVS-L25-P53E-MD-G14-F8-1C1 has the 5/3 function with an exhaust centre position. The number of coils alone does not replace reading the pneumatic symbol.

Closing a single flow path is a different requirement. Separate SMC VDW documentation describes direct-operated 2-way valves and distinguishes variants by medium. Documentation VX21/22/23 similarly distinguishes versions for water, air and other media. Inclusion in the pneumatic category therefore does not by itself confirm the suitability of each item for any liquid.

Selection starts with a description of the working sequence

For your own design, write down which branches should be pressurised and which exhausted for each command. In addition to the working cycle, describe a power failure, loss of air supply and restart. These are three separate situations; assess them according to the diagram of the specific valve and the whole machine.

Then compare the full order code, medium, required flow rate, working pressures and electrical connection. In the category Valves choose the functional version; Plates for terminals addresses the common arrangement of the assembly. For the decision, prepare a sketch of the actual line lengths, service clearances and consumer positions. Also record the measuring points for the acceptance test in the sketch.

Model calculation: volume of connecting hoses

Let us consider only a model assembly of eight hoses, each with an inner diameter of 6 mm and a length of 3 m. The geometric volume of one hose is V = π × d² × L / 4 = π × 0.006² × 3 / 4 = 0.0000848 m³, approximately 0.0848 litres. Eight hoses contain approximately 0.679 litres of internal space.

If each route is shortened to 1.5 m, the total drops to approximately 0.339 litres. The calculation compares only the geometry of two designs. It is not the free air consumption, switching time or parameters of the hoses or valves sold. For a time calculation, it would be necessary to add pressure conditions, the flow characteristic and the volume of the connected equipment.

Mounting and troubleshooting

Instructions SMC for VDW mounting require clean piping and prevention of sealing material entering the valve. When dismantling, it is necessary to disconnect the medium, release the pressure and switch off the power supply. A functional check follows assembly. Always take the specific mounting position and tightening from the documentation of the ordered version.

For the diagnostic record, compare the command, the voltage at the connected coil and the pressures upstream and downstream of the valve at the same moment. Record whether the fault occurs at the first switching, after warming up or during simultaneous operation of other branches. Such a distinction will help decide which part of the circuit to investigate further.

FAQ

Is an identical thread enough for replacement?

No. Compare the function, rest state, pilot version, medium and electrical equipment. The thread describes only one interface; also prepare the original diagram and the full order code.

Does an illuminated connector prove that the valve has switched?

Do not use the indicator light alone as acceptance proof of pneumatic function. Verify the actual response of the circuit. Select electrical parts in the category Accessories according to the exact version of the coil and connector.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.