TEAR2000-02, regulator with pressure gauge, TECHNOLINE
TEAR2000-02, regulator with pressure gauge, flow rate 800Nl/min, working pressure 0-1MPa, connection G1/4 inch, TECHNOLINE
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Compressed air pressure regulators for setting and maintaining the working pressure. Choose by port, pressure range and flow.
TEAR2000-02, regulator with pressure gauge, flow rate 800Nl/min, working pressure 0-1MPa, connection G1/4 inch, TECHNOLINE
TEAR1000-M5, regulator with pressure gauge, flow rate 95Nl/min, working pressure 0-1MPa, connection M5, TECHNOLINE
Regulator with pressure gauge, flow rate 1700Nl/min, working pressure 0-1MPa, connection G3/8 inch, TECHNOLINE
G27-10-R1, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G36-10-01-L, pressure gauge, SMC
G36-10-01, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G46-2-01-L, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G46-4-01-L SMC – pressure gauge. The exact variant is determined by the manufacturer's order code.
G36-2-01-L SMC – pressure gauge. The exact variant is determined by the manufacturer's order code.
G46-4-02-L SMC – pressure gauge. The exact variant is determined by the manufacturer's order code.
G46-10-01-L, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G46-10-N01-L, pressure gauge, SMC
G46-4-02-LN, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G36-2-01-LN, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
G46-10-02-LN, SMC, pressure gauge. The pressure gauge allows local reading of the pressure in the pneumatic system.
AR20-F01H-A, SMC, pressure regulator, modular version. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
pressure regulator; operating pressure: 2 MPa; SMC
AR25-F02H-A, SMC, pressure regulator, modular version. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
AW30-F03H-A, SMC, filter / pressure regulator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
AC20A-F02-A, SMC, modular compressed air preparation unit. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
ARP30K-03BE, SMC, precision pressure regulator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
IR2020-F02G, SMC, pressure regulator. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.
pressure regulator; operating pressure: 1.0MPa; SMC
ITV2150-31F3N, SMC, pneumatic regulator. The regulator maintains or sets the required pressure or vacuum value.
ITV2050-33F3N3, electro-pneumatic regulator for compressed air and vacuum, SMC
Prices include the recycling fee.
An air regulator maintains the set outlet pressure under the relevant operating conditions. The static reading on the pressure gauge and the pressure under consumption are not the same situation. For selection, compare the flow characteristic, inlet pressure and setting range.
| Step | What to document |
|---|---|
| Identification | setting range and ports |
| Operating requirements | peak flow and inlet pressure |
| Acceptance | pressure under actual consumption |
Choose a regulator based on the required pressure at the consumer, not just on the diameter of the connection thread. Prepare operating specifications for rest, the normal working cycle and simultaneous consumption. For each state, we recommend recording the pressure upstream and downstream of the regulator. Such a record will help decide whether you are looking for a different setting range, a more suitable size or the cause of the problem outside the regulator.
SMC AR-D is an air pressure regulator. Its standard table distinguishes the maximum operating pressure of 1.0 MPa from the setting range of 0.05 to 0.85 MPa. The proof pressure is not a permitted working setting. The offered AR20-F02GH-D assess according to the generation D documentation. Do not transfer the values to TEAR or to another AR generation.
The listing includes TEAR1000-M5, TEAR2000-02, TEAR3000-03, AR20-F01H-A and AR25-F02H-A; they are complemented by other regulating versions and pressure gauges. For a part with filtration, see the category Filter regulator. Before ordering, we recommend distinguishing the complete device, the combined unit and the separate gauge according to the full code.
The AR-D manual prescribes operating the knob by hand, reaching the target setting by increasing the pressure and then locking the knob. Before connecting, contaminants are removed from the piping and the interior is protected from sealing material. The tightening torque is chosen according to the specific connection. For service, first isolate the supply and verify depressurisation; normal adjustment is not a dismantling procedure.
For the G36-L and G46-L pressure gauges, the manufacturer relates the accuracy to the full measuring range, not to the value currently read. Coloured zones make it easier to navigate within the required band. For example, G36-10-01-L therefore also choose according to range and connection. Do not consider a change in scale colour to be a change in regulation properties.
The following is our own measurement model, not a parameter of a specific regulator. At rest, let us assume 0.50 MPa at the outlet. At a specified consumption of 240 l/min with the same reference conditions, we measure 0.46 MPa downstream of the regulator and 0.42 MPa at the consumer. The difference between rest and the loaded outlet is 0.50 − 0.46 = 0.04 MPa. The simultaneous loss of the downstream branch is 0.46 − 0.42 = 0.04 MPa. The total difference from the rest value is 0.08 MPa.
The culprit cannot be determined from these three numbers. For the next step of the model, let us add a simultaneous measurement at the inlet: if the supply pressure also changes, we are already comparing two influences. We recommend evaluating the results with the same consumption repeated and recording the knob position. Simply increasing the rest setting would make it impossible to compare the original conditions.
For another example of our own, consider a gauge with a range up to 1 MPa and a permissible error of 2 % of the full scale. The absolute error limit is 0.02 MPa. Such a gauge cannot reliably distinguish a change of just one hundredth of an MPa. This is a hypothetical gauge, not a specification of the offered G pressure gauge.
Divide the observations into a permanent fault and a fault linked to a certain phase of the machine. Note the time, active consumers and the reading point. The proposed procedure allows the supply, regulator and downstream branch to be compared separately. During the test, always change one condition; otherwise it may not be clear which adjustment affected the result.
SMC explicitly does not allow this for AR-A. Protection of the equipment against impermissible pressure must be based on the design of the whole circuit.
Request the characteristic for the intended inlet pressure, outlet setting and the reference flow conditions used. A number alone without an operating point is not enough for selection.
Primary sources: SMC AR-D, SMC AR-A, SMC G pressure gauges.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.