XM203015, EAE, stainless steel wall-mounted distribution board, 200×300×150mm (H×W×D), AISI304, IP66, with mounting plate
XM203015, EAE, stainless steel wall-mounted distribution board, 200×300×150mm (H×W×D), AISI304, IP66, with mounting plate
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Stainless steel enclosures for the food industry, outdoor and aggressive environments. Choose by size, door or lid, protection rating and mounting plate.
XM203015, EAE, stainless steel wall-mounted distribution board, 200×300×150mm (H×W×D), AISI304, IP66, with mounting plate
XM302015, EAE, stainless steel control cabinet enclosure, 300×200×150mm, IP66. XM series stainless steel monobloc control cabinet enclosure with dimensions 300×200×150mm for applications requiring…
XM606030, EAE, stainless steel control cabinet enclosure, 600×600×300mm, IP66. XM series stainless steel monobloc control cabinet enclosure with dimensions 600×600×300mm for applications requiring…
EXET2030, EAE, stainless steel terminal box with mounting plate, 200×300×120mm, IP66. EAE EXET2030 stainless steel terminal box with dimensions 200×300×120mm for housing electrical and control…
EX302012, EAE: stainless steel enclosure, outer dimensions 300×200×120mm (H×W×D); for fitting electrical components.
EX203010, EAE, stainless steel wall-mounted distribution board, 200×300×100mm (H×W×D), with mounting plate
EX302015, EAE, stainless steel wall-mounted distribution board, 300×200×150mm (H×W×D), with mounting plate
XM404020, EAE, stainless steel control cabinet enclosure, 400×400×200mm, IP66. XM series stainless steel monobloc control cabinet enclosure with dimensions 400×400×200mm for applications requiring…
Stainless steel control cabinet enclosure EAE, EX series, with dimensions 400×300×200mm. The version is intended for wall-mounted fitting of devices and conductor routes in the control cabinet.
XM505020, EAE: stainless steel enclosure, outer dimensions 500×500×200mm (H×W×D); for fitting electrical components.
Prices include the recycling fee.
This category contains EAE EXET, EX and XM stainless steel enclosures. EXET2030 has a screwed lid; for example, EX203010 and XM203015 are versions with doors. So start with the way of accessing the devices, the environment and the space required. The category name alone does not determine the electrical equipment of the delivery.
For the current XM series, the manufacturer distinguishes materials AISI 304 and 316. Data on one variant therefore does not determine the material of all enclosures offered. Before selecting, request confirmation of the grade of the specific code, the lock version and the seal.
For the brief, note whether the enclosure is only wiped or will be exposed to liquids, and which cleaning agents are used. The name “stainless” alone does not express compatibility with the chosen chemicals. Also assess the areas under the seal and around the glands: that is exactly where dirt can accumulate and moisture remain. Verify the suitability of cleaning for the whole combination of materials.
Compare dimensions in the same order: height, width and depth. The outer depth is not the usable distance in front of the mounting plate. The design must also include connectors, conductor bending radii and tool access. An enclosure into which a device fits snugly may not yet allow it to be wired or later replaced. When planning servicing, also verify that a terminal can be released and the whole part pulled out without dismantling adjacent components; a small front gap often does not reveal this need.
Suppose a device protrudes 85 mm in front of the mounting surface, another 35 mm for connection and a chosen reserve of 20 mm. We need 85 + 35 + 20 = 140 mm of usable depth. With a model measured 135 mm, the assembly does not fit. These are our own teaching values, not parameters of EXET, EX or XM; the example does not address temperature rise or electrical clearances.
Before drilling, prepare the layout of the entries and their distance from the plate, edges and sealing surface. Carry out machining without fitted electrical equipment and remove chips. Use fixings and glands that match the specific enclosure and the cable diameter. The seal must not be twisted or pinched by a conductor. Electrical fitting, protective bonding of metal parts and verification of the assembly belong to a qualified person.
If moisture appears, record its location and its relationship to cleaning or temperature changes. Water at an entry leads to checking the gland; traces along the doors to checking the seating and the seal. Drops on several internal surfaces may be related to condensation. Replacing the seal alone therefore may not eliminate the cause. After the intervention, verify the result under the same operating conditions.
No. The specific conditions, cleaning method and design of all parts are decisive. The wall material alone does not prove the suitability of the whole installation for the workplace.
Not automatically. Verify the scope of delivery and the fitting design. An empty enclosure or an enclosed mounting plate does not represent a documented finished electrical assembly.
Compare other variants in the category Control cabinet enclosures. For modular fitting, continue with Surface-mounted distribution boards, for a different material version Sheet steel control cabinet enclosures.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.