Branch fitting

Threaded branch fittings (T-pieces) for branching the line. Choose by tube diameter and thread.

Filters
Found 97 products

Prices include the recycling fee.

Branch fitting

A branch fitting connects several lines to one connection point. The range includes Pneuflex TPB and TPD as well as metal versions TBPB/TBPD. Representative items are TPB08-G01 a TPD08-G02. Start the selection with a sketch of all three connections.

The thread position determines the branch arrangement

Pneuflex PB-G connects two tubes perpendicular to the axis of the threaded branch. For PD-G the thread lies at the end of the main straight path; the second tube connection forms a side branch. Both manufacturing sheets therefore describe a different layout of interfaces. For ordering, compare the drawing, not just the T-shape designation.

In your own diagram, mark the source, both branches and the measuring point. Assign a consumer and the required working sequence to each branch. The shape of the branching does not by itself determine the sequence of consumption. If the branches are to work independently, also draw their actual control and the conditions of the acceptance test.

Selection by simultaneous operation of consumers

First write down the situation when only one branch is active, then both simultaneously. For comparison, prepare flow requirements in the same reference and pressures at the decisive points. Supplement the value upstream of the branching with a check at the consumers. The thread size or tube inlet alone is not a flow characteristic of the finished assembly.

Model calculation: average and simultaneous consumption

For our own example, let us assume two consumers with flow rates expressed against the same reference: the first 70 litres per minute during its active phase, the second 50 litres per minute. During their full simultaneous operation, the model requirement of the common branch is 70 + 50 = 120 litres per minute.

Let us further assume a periodic cycle in which the first consumer draws air for a quarter of the time and the second for two fifths of the time; outside the active phase they have zero consumption in the model. The long-term average is 70 × 0.25 + 50 × 0.40 = 37.5 litres per minute. This sum applies to the specified time shares regardless of their overlap.

However, the average does not describe the moment when both consumers are working. In the design, therefore, separate the average consumption from the required simultaneity. The numbers are original model inputs; they do not represent the flow rate of any offered branch fitting. The calculation does not address pressure losses, filling of volumes or regulation response. For actual selection, the characteristic of the specific circuit is required.

Mounting with access to all inputs

Draw each tube separately in the spatial sketch. Verify the space for its disconnection and for the tool on the threaded side. For closely adjacent branches, determine the mounting order and add branch identification. Marking at both ends of the line will help compare the actual distribution with the diagram during service.

The prescribed insertion length look in the dimensional documentation of the specific part. Therefore verify the prepared lengths of both branches separately.

Diagnostics during simultaneous operation

As our own test procedure, record separate operation of the first branch, the second branch and their simultaneous operation. In all three situations, compare the control demand, pressures at the consumers and the result of the working sequence. A problem common to both branches leads to checking the common path; a problem in one branch requires comparing its own line and configuration.

If you need to change the orientation of the supply, compare Elbow fitting throughout the sketch. For direct connection of a separate consumer, use Straight fitting; adding a branch should be based on the required function of the distribution.

FAQ

Is the flow automatically split in half?

Do not assume such a distribution for selection. Describe the requirements of both branches and verify their behaviour separately and during simultaneous operation; the model with the same reference only serves to balance the specified consumption.

Is it enough to order any T-shaped fitting?

Compare the arrangement of connections, thread, tubes and service access. An overview of designs can be found in the category Threaded fitting; determine the final version according to its drawing.