Phone +420 774 723 123 Cart · 0 · empty

Power Supplies

Power supplies for automation, control cabinets and machines – 5, 12, 24 and 48 V DC switched-mode supplies for DIN rail and panel mounting from MEAN WELL, Siemens, Omron, Balluff, IDEC and others. Choose by output voltage and current with reserve, supply network, dimensions and operating temperature.

Subcategories

Filters
Found 330 products
OUR TIP IN STOCK

AMR1-24-X, Chinfa, low-profile power supply; voltage: 24V DC; power: 10W; current: 0.42A, 90 - 264V AC, 0.42 A

Cat. no.: AMR1-24-X

AMR1-24-X Chinfa – low-profile power supply; voltage: 24V DC; power: 10W; current: 0.42A, 90 - 264V AC, 0.42 A. Key data: 50 - 63Hz. Exact technical data for selecting the switched-mode power supply…

In stock 5 or more pcs
16,34 €
excl. VAT · 19,77 € incl. VAT
IN STOCK

RPS-15-24, Rievtech, switched-mode DIN-rail power supply, 24VDC/0.63A, 15W

Cat. no.: RPS-15-24

RPS-15-24, Rievtech: DIN-rail power supply for powering automation, output 24VDC/0.63A, 15W, input 85–264VAC.

In stock 5 or more pcs
17,32 €
excl. VAT · 20,96 € incl. VAT
OUR TIP IN STOCK

DRS1-24A, Chinfa, power supply; voltage: 24VDC; current: 1.25A; power: 30W, 24V DC, 1.25A

Cat. no.: DRS1-24A

DRS1-24A Chinfa – power supply; voltage: 24VDC; current: 1.25A; power: 30W, 24V DC, 1.25A. Key data: 85 - 264V AC, 50 - 63Hz. Exact technical data for selecting the switched-mode power supply type.

In stock 5 or more pcs
19,12 €
excl. VAT · 23,14 € incl. VAT
IN STOCK

RPS-15-S24 – Rievtech – slim switched-mode DIN-rail power supply, 24VDC/0.65A, 15W, 90–264VAC

Cat. no.: RPS-15-S24

RPS-15-S24 – Rievtech – slim switched-mode DIN-rail power supply, 24VDC/0.65A, 15W, input 90–264VAC. DIN rail, efficiency 84.5%, operation −25 to +70°C, dimensions 103.7×32×97.5mm.

In stock 5 or more pcs
19,49 €
excl. VAT · 23,58 € incl. VAT
OUR TIP IN STOCK

AMR2-24-X, CHINFA, low-profile switched-mode DIN-rail power supply, 24VDC/1A, 24W

Cat. no.: AMR2-24-X

AMR2-24-X, CHINFA: low-profile switched-mode DIN-rail power supply with an output of 24VDC/1A, a power of 24W and an input of 90–264VAC.

In stock 5 or more pcs
20,84 €
excl. VAT · 25,22 € incl. VAT
OUR TIP IN STOCK

DRA18-24A-X, Chinfa, DIN power supply, 24VDC/0.75A, 18W

Cat. no.: DRA18-24A-X

DRA18-24A-X, Chinfa, DIN power supply, 24VDC/0.75A, 18W. The compact DRA18 series power supply provides a regulated 24VDC/0.75A for low-power control and signalling circuits.

In stock 5 or more pcs
22,07 €
excl. VAT · 26,70 € incl. VAT
OUR TIP IN STOCK

DRA18-24-X, Chinfa, switched-mode DIN-rail power supply, 24VDC/0.75A, 18W

Cat. no.: DRA18-24-X

DRA18-24-X, Chinfa, switched-mode DIN-rail power supply, 24VDC/0.75A, 18W. The DRA18 series power supply for industrial automation provides a regulated output of 24VDC with a maximum catalogue…

In stock 5 or more pcs
22,48 €
excl. VAT · 27,20 € incl. VAT
OUR TIP IN STOCK

DRS2-24A, Chinfa, switched-mode DIN-rail power supply, 24VDC/2.1A, 50W

Cat. no.: DRS2-24A

DRS2-24A, Chinfa, switched-mode DIN-rail power supply, 24VDC/2.1A, 50W. The DRS2 series power supply for industrial automation provides a regulated output of 24VDC with a maximum catalogue current of…

In stock 5 or more pcs
22,97 €
excl. VAT · 27,80 € incl. VAT
OUR TIP IN STOCK

AMR2-12-X, CHINFA, low-profile switched-mode DIN-rail power supply, 12VDC/2A, 24W

Cat. no.: AMR2-12-X

AMR2-12-X, CHINFA: low-profile switched-mode DIN-rail power supply with an output of 12VDC/2A, a power of 24W and an input of 90–264VAC.

In stock 5 or more pcs
24,52 €
excl. VAT · 29,67 € incl. VAT
OUR TIP IN STOCK

AMR3-24-X, CHINFA, low-profile switched-mode DIN-rail power supply, 24VDC/1.5A, 36W

Cat. no.: AMR3-24-X

AMR3-24-X, CHINFA: low-profile switched-mode DIN-rail power supply with an output of 24VDC/1.5A, a power of 36W and an input of 90–264VAC.

In stock 5 or more pcs
26,37 €
excl. VAT · 31,91 € incl. VAT
OUR TIP IN STOCK

DRAN30-24A-X, Chinfa, power supply 24V DC (30W/1.25A), 90 - 264V AC, 1.25A, 30 W

Cat. no.: DRAN30-24A-X

DRAN30-24A-X Chinfa – power supply 24V DC (30W/1.25A), 90 - 264V AC, 1.25A, 30 W. Key data: DIN rail. Exact technical data for selecting the switched-mode power supply type.

In stock 5 or more pcs
27,40 €
excl. VAT · 33,15 € incl. VAT
OUR TIP IN STOCK

AMR3-12-X, Chinfa, low-profile power supply 12V DC (33W/2.75A), screw connection, 90 - 264V AC, 2.75 A, 33 W

Cat. no.: AMR3-12-X

AMR3-12-X Chinfa – low-profile power supply 12V DC (33W/2.75A), screw connection, 90 - 264V AC, 2.75 A, 33 W. Key data: 50 - 63Hz. Exact technical data for selecting the switched-mode power supply…

In stock 5 or more pcs
27,39 €
excl. VAT · 33,14 € incl. VAT
IN STOCK

RPS-45-24, Rievtech, switched-mode DIN-rail power supply, 24VDC/2A, 48W

Cat. no.: RPS-45-24

RPS-45-24, Rievtech, industrial switched-mode DIN-rail power supply: output 24VDC/2A (48W), input 85–264VAC, output adjustment 21.6–26.4VDC.

In stock 5 or more pcs
28,26 €
excl. VAT · 34,19 € incl. VAT
OUR TIP IN STOCK

AMR4-24-X, CHINFA, low-profile switched-mode DIN-rail power supply, 24VDC/2.5A, 60W

Cat. no.: AMR4-24-X

AMR4-24-X, CHINFA: low-profile switched-mode DIN-rail power supply with an output of 24VDC/2.5A, a power of 60W and an input of 90–264VAC.

In stock 5 or more pcs
28,58 €
excl. VAT · 34,58 € incl. VAT
OUR TIP IN STOCK

DRS3-24A, CHINFA, switched-mode DIN-rail power supply, 24VDC/3A, 72W

Cat. no.: DRS3-24A

DRS3-24A, CHINFA: switched-mode DIN-rail power supply, 24VDC/3A, power 72W, input 85–264VAC, screw terminals.

In stock 5 or more pcs
28,62 €
excl. VAT · 34,63 € incl. VAT
OUR TIP IN STOCK

AMR4-12-X, Chinfa, low-profile DIN power supply, 12VDC/4.5A, 54W

Cat. no.: AMR4-12-X

AMR4-12-X, Chinfa, low-profile DIN power supply, 12VDC/4.5A, 54W. Low-profile power supply AMR4 for control cabinets and installations where a regulated 12VDC. supply is required

In stock 5 or more pcs
29,03 €
excl. VAT · 35,13 € incl. VAT
IN STOCK

RPS-60-24, Rievtech, switched-mode DIN-rail power supply, 24VDC/2.5A, 60W

Cat. no.: RPS-60-24

The Rievtech power supply RPS-60-24 creates a regulated output of 24VDC for supplying control circuits. It continuously delivers a rated current of 2.5A; for this model, the manufacturer states 60W.

In stock 5 or more pcs
30,05 €
excl. VAT · 36,37 € incl. VAT
IN STOCK

RPS-60-S24, Rievtech, switched-mode DIN-rail power supply, 24VDC/2.5A, 60W

Cat. no.: RPS-60-S24

RPS-60-S24, Rievtech, switched-mode DIN-rail power supply, 24VDC/2.5A, 60W. Model S24 of the RPS-60-S series provides DC power for control circuits with an output current of 2.5A.

In stock 5 or more pcs
32,26 €
excl. VAT · 39,04 € incl. VAT
OUR TIP IN STOCK

DRAN60-12A-X, Chinfa, switched-mode DIN-rail power supply, 12VDC/5A, 60W

Cat. no.: DRAN60-12A-X

DRAN60-12A-X, Chinfa, switched-mode DIN-rail power supply, 12VDC/5A, 60W. The DRAN60 series power supply for industrial automation provides a regulated output of 12VDC with a maximum catalogue…

In stock 5 or more pcs
32,72 €
excl. VAT · 39,59 € incl. VAT
OUR TIP IN STOCK

AMR5-24-X, Chinfa, switched-mode DIN-rail power supply, 24VDC/4.2A, 100.8W

Cat. no.: AMR5-24-X

AMR5-24-X, Chinfa, switched-mode DIN-rail power supply, 24VDC/4.2A, 100.8W. The AMR5 series power supply for industrial automation provides a regulated output of 24VDC with a maximum catalogue…

In stock 5 or more pcs
33,17 €
excl. VAT · 40,14 € incl. VAT
OUR TIP IN STOCK

DRS5-24A, Chinfa, switched-mode DIN-rail power supply, 24VDC/5A, 120W

Cat. no.: DRS5-24A

DRS5-24A, Chinfa, switched-mode DIN-rail power supply, 24VDC/5A, 120W. The DRS5 series power supply for industrial automation provides a regulated output of 24VDC with a maximum catalogue current of…

In stock 5 or more pcs
44,88 €
excl. VAT · 54,31 € incl. VAT
IN STOCK

RPS-100-24 – Rievtech – switched-mode DIN-rail power supply, 24VDC/4A, 96W, 85–264VAC

Cat. no.: RPS-100-24

RPS-100-24 – Rievtech – switched-mode DIN-rail power supply, 24VDC/4A, 96W, input 85–264VAC. DIN rail, efficiency 87%, operation −20 to +60°C, dimensions 100×93×56mm.

In stock 5 or more pcs
46,55 €
excl. VAT · 56,33 € incl. VAT
OUR TIP IN STOCK

DRA240-24A-X, Chinfa, DIN power supply, 24VDC/10A, 240W, screw terminals

Cat. no.: DRA240-24A-X

DRA240-24A-X, Chinfa, DIN power supply, 24VDC/10A, 240W, screw terminals. DRA240 is a 240W switched-mode power supply for control circuits with a voltage of 24VDC.

In stock 5 or more pcs
72,88 €
excl. VAT · 88,18 € incl. VAT
OUR TIP IN STOCK

WRA480-24A-X, Chinfa, wRA480-24, power supply, 24V DC, 20A, 480W

Cat. no.: WRA480-24A-X

WRA480-24A-X Chinfa – wRA480-24, power supply, 24V DC, 20A, 480W. Key data: 340 - 575V AC, 50 - 63Hz. Exact technical data for selecting the switched-mode power supply type.

In stock 5 or more pcs
116,69 €
excl. VAT · 141,19 € incl. VAT

Prices include the recycling fee.

Power supplies

Choose a power supply as part of the entire supply circuit: from the mains feed through the control cabinet to the terminals of the most distant load. The correct output voltage is the first condition, not full confirmation of compatibility. The current during normal operation and start-up, the temperature inside the enclosure, protection, mounting method and the requirements of the connected equipment for protective separation are also decisive.

What this branch includes

The catalogue divides the range into the categories Allen-Bradley power supplies, IDEC 5/12/24V DC power supplies, CHINFA 12/24V DC power supplies, PULS 24V DC power supplies, Rievtech power supplies and Siemens power supplies. Catalogue items include, for example, CHINFA DRS1-24A and DRS5-24A, PULS PIC120.241C, Rievtech RPS-60-24 and several Siemens order codes. The parameters of these products are not common parameters of the whole category. The existence of the branch also does not confirm the availability of a specific type.

How a switched-mode regulated power supply works

A switched-mode power supply converts input energy using a rapidly switched power circuit; feedback adjusts the operation so that the output holds the required voltage within the permitted limits. Output filtering limits ripple but does not eliminate all transients. The basic difference from a linear power supply is described in the IDEC technical FAQ. For sensitive analogue measurement, therefore check not only the rated voltage but also the ripple, permissible interference and the routing of common return conductors.

Continuous load, simultaneity and peaks

List all loads by voltage branch. For each, record the highest operating current, short-term consumption, its duration and when it occurs. Do not calculate the coil current from the current capacity of its contacts; the figure on a relay output is not the relay's consumption. For equipment with externally powered outputs, check whether the documented consumption also includes the connected loads. Do not count the same current twice.

The required continuous current is determined by the worst permissible simultaneous operation, not by the average over a shift. Compare the peak with the overload characteristic of the selected power supply, including its duration and repetition. The boost designation alone is not enough. Design the reserve according to expansion and actual operating uncertainties; a universal percentage does not replace assessment of the start-up.

Model example of a current balance

Consider a hypothetical 24 V branch: the controller draws 0.45 A, the panel 0.35 A, eight sensors 0.03 A each and four simultaneously energised coils 0.12 A each. The sum is 1.52 A, i.e. 36.48 W. If the panel needs 1.10 A instead of 0.35 A at switch-on for 80 ms, the simultaneous consumption rises to 2.27 A. These are chosen inputs for the example, not data of the devices offered.

A power supply with a rated current of 2 A cannot be approved from the first sum alone, nor automatically rejected from the second: the permissible time characteristic and the voltage drop will decide. If we do not know it, we do not assume a short-term reserve. Delaying some loads can only help if their sequence is also ensured after the power supply is restored.

Derating, losses and space in the control cabinet

Derating means reducing the permissible load under specified conditions. It may relate to ambient temperature, altitude or a different mounting position; the curve of the specific type is decisive, as explained in the PULS guide to derating. The upper operating temperature is not automatically the temperature for full power. Assess the air at the power supply, not just the room temperature.

Your own design check should include the width on the rail, the depth including terminals, conductor bending and the prescribed ventilation clearances. Losses also belong in the heat balance. As a model, with an output of 100 W and an assumed efficiency of 90 %, approximately 11.1 W of heat is generated: 100 / 0.90 − 100. However, determine the efficiency of the chosen product for the actual load. Free space above the device does not replace verification of airflow in the enclosure.

Input inrush current and protection

AC inrush is a short input current when charging capacitors after connection to the mains. It is not the same as the starting current of a load on the DC output. The cause and methods of limiting it are described in the PULS documentation on inrush current. When several power supplies are switched on together, check the entire feed, the switching element and the manufacturer's recommendations. The ratio of output watts to mains voltage alone is not enough to choose a circuit breaker.

On the output, coordinate the protection of the individual branches with the current limiting of the power supply and the resistance of the wiring. The power supply may limit the current before an ordinary circuit breaker trips quickly; this relationship is discussed in PULS: protection of DC circuits. The specific solution must suit the cabling, load and required selectivity. The internal protection of the power supply does not automatically replace the protection of every branch.

SELV and PELV are not designations of 24 V

Both extra-low-voltage protective systems require appropriate protective separation from higher-voltage circuits. SELV maintains separation from earth; PELV allows earthing according to the protection design. The difference is explained in Schneider Electric documentation on SELV and the relationship between SELV and PELV. Connecting the protective conductor to the chassis of the power supply is not the same as connecting the negative output to earth.

Assess suitability for the whole circuit, including connections to other devices. 24 V alone, a plastic housing or the general brand of the manufacturer do not prove SELV or PELV. The equipment requirements, specific documents and earthing method must match.

Voltage at the load and verification procedure

Also check the voltage at the load at maximum consumption. As a model, a total loop resistance of 0.4 Ω at 1.5 A creates a drop of 0.6 V. By increasing the supply voltage you may overload nearby devices; first assess the conductors, length and distribution of branches.

  1. Verify the input network, number of phases, output voltage and polarity.
  2. Compare the current balance with the permissible load after derating and with the start-up.
  3. Check the mounting, terminals, protective connection and coordination of protection.
  4. During commissioning, verify start-up of the whole assembly, the voltage at the load and behaviour after a power failure. Mains wiring and interventions are carried out by a qualified person according to the documentation, de-energised and after securing the workplace.

FAQ

Can I connect two outputs and get double the current?

Only with parallel operation permitted by the manufacturer and meeting its conditions. Redundancy also requires capacity for the fault state and suitable separation of branches; the difference is described in PULS: parallel operation and redundancy. Two power supplies loaded together to the maximum do not provide backup if one fails.

Will a more powerful power supply solve every PLC restart?

No. First separate insufficient power from voltage drop on the wiring, overload of one branch, interference or an intermittent contact. Record during which event the problem occurs; replacement without this distinction may leave the real cause untouched.

Cookies on this website