Phone +420 774 723 123 Cart · 0 · empty

32-Pin Metal Connectors

32-pin EMAS EBM metal connectors for interfaces with a larger number of conductors. Compare cable and fixed plugs and sockets, empty housings and covers. For inserts, also check the numbering of the contact positions and their arrangement in the assembly.

Filters
Found 30 products
OUR TIP IN STOCK

EBA32TK, EMAS, protective cover for EB series industrial connector, size 32

Cat. no.: EBA32TK

EBA32TK – EMAS protective cover for 32-pin industrial connectors. Separate accessory without contacts. Verify the housing size and fixing method.

In stock 5 or more pcs
2,21 €
excl. VAT · 2,67 € incl. VAT
OUR TIP IN STOCK

EBM32FU30, EMAS, industrial plug, 32, 16A

Cat. no.: EBM32FU30

EBM32FU30 – 32-pin EMAS EBM metal industrial connector, male version, 16 A. Connector with a contact insert for detachable connection of cables and equipment.

In stock 5 or more pcs
20,88 €
excl. VAT · 25,26 € incl. VAT
−3 % OUR TIP IN STOCK

EBM32FU10, EMAS, industrial plug, 32, 16A

Cat. no.: EBM32FU10

EBM32FU10 – 32-pin EMAS EBM metal industrial connector, male version, 16 A. Connector with a contact insert for detachable connection of cables and equipment.

In stock 5 or more pcs
21,06 € 21,71 €
excl. VAT · 25,48 € incl. VAT
−3 % OUR TIP IN STOCK

EBM32PM44, EMAS, industrial socket, 32, 16A

Cat. no.: EBM32PM44

EBM32PM44 – 32-pin EMAS EBM metal industrial connector, female version, 16 A. Connector with a contact insert for detachable connection of cables and equipment.

In stock 5 or more pcs
22,67 € 23,37 €
excl. VAT · 27,43 € incl. VAT
OUR TIP

EBM32GU10, EMAS, cable empty housing for industrial connector, 32 poles, 16A, side entry, PG21, IP65

Cat. no.: EBM32GU10

EBM32GU10, EMAS – cable empty housing for EBM industrial multi-pole connector, 32 poles, 16A, side entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an empty…

On request
8,36 €
excl. VAT · 10,11 € incl. VAT
OUR TIP

EBM32GU30, EMAS, cable empty housing for industrial connector, 32 poles, 16A, top entry, PG21, IP65

Cat. no.: EBM32GU30

EBM32GU30, EMAS – cable empty housing for EBM industrial multi-pole connector, 32 poles, 16A, top entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an empty…

On request
8,36 €
excl. VAT · 10,11 € incl. VAT

EBM32GU10-PG29, EMAS, portable empty housing 32p, side entry

Cat. no.: EBM32GU10-PG29

EMAS EBM32GU10-PG29: portable empty housing, 32p, side entry. EBM industrial series.

On request
8,37 €
excl. VAT · 10,13 € incl. VAT

EBM32GU30-PG29, EMAS, portable empty housing 32p, top entry

Cat. no.: EBM32GU30-PG29

EMAS EBM32GU30-PG29: portable empty housing, 32p, top entry. EBM industrial series.

On request
8,37 €
excl. VAT · 10,13 € incl. VAT
OUR TIP

EBM32GM44, EMAS, panel empty housing for industrial connector, 32 poles, 16A, bottom entry, 4 latches, PG21, IP65

Cat. no.: EBM32GM44

EBM32GM44, EMAS – panel empty housing for EBM industrial multi-pole connector, 32 poles, 16A, bottom entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an…

On request
9,22 €
excl. VAT · 11,15 € incl. VAT

EBM32GU14, EMAS, portable empty housing 32p, side entry, 4 levers

Cat. no.: EBM32GU14

EMAS EBM32GU14: portable empty housing, 32p, side entry, with four levers. EBM industrial series.

On request
11,80 €
excl. VAT · 14,27 € incl. VAT

EBM32GU34, EMAS, portable empty housing 32p, top entry, 4 levers

Cat. no.: EBM32GU34

EMAS EBM32GU34: portable empty housing, 32p, top entry, with four levers. EBM industrial series.

On request
11,80 €
excl. VAT · 14,27 € incl. VAT

EBM32FU10-PG29, EMAS, portable plug 32p 16A, side entry

Cat. no.: EBM32FU10-PG29

EMAS EBM32FU10-PG29: portable plug, 32p, side entry, 16A. EBM industrial series.

On request
22,57 €
excl. VAT · 27,31 € incl. VAT

EBM32FU30-PG29, EMAS, portable plug 32p 16A, top entry

Cat. no.: EBM32FU30-PG29

EMAS EBM32FU30-PG29: portable plug, 32p, top entry, 16A. EBM industrial series.

On request
22,57 €
excl. VAT · 27,31 € incl. VAT

EBM32PU10-PG29, EMAS, portable socket 32p 16A, side entry

Cat. no.: EBM32PU10-PG29

EMAS EBM32PU10-PG29: portable socket, 32p, side entry, 16A. EBM industrial series.

On request
23,79 €
excl. VAT · 28,78 € incl. VAT

EBM32PU30-PG29, EMAS, portable socket 32p 16A, top entry

Cat. no.: EBM32PU30-PG29

EMAS EBM32PU30-PG29: portable socket, 32p, top entry, 16A. EBM industrial series.

On request
23,79 €
excl. VAT · 28,78 € incl. VAT
OUR TIP

EBM32PU10, EMAS, industrial plug, 32, 16A

Cat. no.: EBM32PU10

EBM32PU10 – 32-pin EMAS EBM metal industrial connector, female version, 16 A. Connector with a contact insert for detachable connection of cables and equipment.

On request
24,39 €
excl. VAT · 29,51 € incl. VAT
OUR TIP

EBM32PU30, EMAS, industrial plug, 32, 16A

Cat. no.: EBM32PU30

EBM32PU30 – 32-pin EMAS EBM metal industrial connector, female version, 16 A. Connector with a contact insert for detachable connection of cables and equipment.

On request
24,39 €
excl. VAT · 29,51 € incl. VAT

EBM32PU14, EMAS, portable socket 32p 16A, side entry, 4 levers

Cat. no.: EBM32PU14

EMAS EBM32PU14: portable socket, 32p, side entry, 16A, with four levers. EBM industrial series.

On request
25,99 €
excl. VAT · 31,45 € incl. VAT

EBM32PU34, EMAS, portable socket 32p 16A, top entry, 4 levers

Cat. no.: EBM32PU34

EMAS EBM32PU34: portable socket, 32p, top entry, 16A, with four levers. EBM industrial series.

On request
25,99 €
excl. VAT · 31,45 € incl. VAT

Prices include the recycling fee.

32-pin EMAS EBM metal industrial connectors

32-pin EMAS EBM metal connectors for interfaces with a larger number of conductors. Compare cable and fixed plugs and sockets, empty housings and covers. For inserts, also check the numbering of the contact positions and their arrangement in the assembly.

What the range here includes

You can choose, for example, EBM32FU10, EBM32FU30, EBM32PU10, EBM32PU30, EBM32FM44, EBM32PM44 and protective cover EBA32TK. The EMAS overview distinguishes cable entry variants and fixed mounting. The name plug or socket alone is not enough to determine the complete contents of the pack.

The EB insert manufacturer overview states numbering 17–32, for EB032CF00, while EB016CF00 carries 1–16. This is important information when reading the assembly drawing. It does not mean that any sixteen-pole insert or any older variant automatically belongs in your housing.

The numbering must correspond to the physical orientation

For each part of the assembly, record its code, position and reference view. The description “first block on the left” is ambiguous if it is not clear where the observer is looking from. Better documentation shows the mating face, distinguishes both connector halves and gives the position designations according to the manufacturer.

When processing the cable list, do not automatically renumber all positions of the second insert back from one. Service would then work with two different meanings of the same number. If the project uses its own block designations, keep the corresponding original contact numbers in the table as well.

Check before connecting the machine

For a multi-part interface, prepare a checklist for each block, not just one result for the whole housing. Check the identification of the parts, the assignment of positions and the continuity to the connected terminals. The record will make it possible to determine, in the event of a later fault, which part needs to be compared with the original state.

During a service replacement, do not confuse visually similar cable assemblies of different stations. The connector designation, diagram revision and identification of the connected module must form a single whole. If the drawing of the original wiring is missing, first have it professionally verified; simply rewiring according to a photo may overlook the orientation of the insert. Other variants are in the parent connector range.

FAQ

Is the number 32 in the code proof of a single thirty-two-pole insert?

No. The design and numbering are determined by the specific manufacturer documentation, not by the numerical part of the name.

Is it enough to keep the position of the cable entry when replacing?

The inserts, counterpart, locking, wiring and required electrical conditions must also be confirmed.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.