PSA010AK141E, EMAS, safety cam switch 0-1, 1pole, 10A, 90 °, IP54
Single pole safety cam switch EMAS PSA010AK141E, 10A, position 0-1, turn 90 °, IP54, front frame 48 × 48mm.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Implementation 0-1 with 90 ° angle and resolution of proven switching and safety functions.
Single pole safety cam switch EMAS PSA010AK141E, 10A, position 0-1, turn 90 °, IP54, front frame 48 × 48mm.
Single-pole safety cam switch EMAS PSA016AK141E, 16A, position 0-1, turn 90 °, IP54, front frame 48 × 48mm.
Single pole safety cam switch EMAS PSA020AK141E, 20A, position 0-1, 90 ° rotation, IP54, front frame 48 × 48mm.
Three-pole safety cam switch EMAS PSA010AK341E, 10A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
Single pole safety cam switch EMAS PSA025AK141E, 25A, position 0-1, 90 ° rotation, IP54, front frame 48 × 48mm.
Three-pole safety cam switch EMAS PSA016AK341E, 16A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
EMAS single-pole safety cam switch PSA032AK141E, 32A, position 0-1, 90 ° rotation, IP54, front frame 64 × 64mm.
Three-pole safety cam switch EMAS PSA025AK341E, 25A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
Single-pole safety cam switch EMAS PSA040AK141E, 40A, position 0-1, turn 90 °, IP54, front frame 64 × 64mm.
The safety main cam switch EMAS PSA025AK941E for three phases and neutral wire (3P + N), 25A, switch 0-1 by 90 °, IP54, forehead 48 × 48mm.
Three-pole EMAS safety cam switch PSA032AK341E, 32A, control 0-1, 90 °, IP54, front frame 64 × 64mm. For three separately switched poles.
Safety main cam switch EMAS PSA032AK941E for three phases and neutral wire (3P + N), 32A, switch 0-1 by 90 °, IP54, forehead 64 × 64mm.
Three-pole safety cam switch EMAS PSA040AK341E, 40A, control 0-1, 90 °, IP54, front frame 64 × 64mm. For three separately switched poles.
Three-pole safety cam switch EMAS PSA050AK341E, 50A, control 0-1, 90 °, IP54, front frame 64 × 64mm. For three separately switched poles.
Three-pole EMAS safety cam switch PSA063AK341E, 63A, control 0-1, 90 °, IP54, front frame 64 × 64mm. For three separately switched poles.
Two-pole EMAS safety cam switch PSA010AK241E for two switched poles, 10A, position 0-1, 90 °, IP54, front frame 48 × 48mm.
Two-pole EMAS safety cam switch PSA016AK241E for two switched poles, 16A, position 0-1, 90 °, IP54, front frame 48 × 48mm.
Two-pole EMAS safety cam switch PSA020AK241E for two switched poles, 20A, position 0-1, 90 °, IP54, front frame 48 × 48mm.
Safety main cam switch EMAS PSA010AK941E for three phases and neutral wire (3P + N), 10A, switch 0-1 by 90 °, IP54, forehead 48 × 48mm.
Safety main cam switch EMAS PSA016AK941E for three phases and neutral wire (3P + N), 16A, switch 0-1 by 90 °, IP54, forehead 48 × 48mm.
Three-pole safety cam switch EMAS PSA020AK341E, 20A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
Two-pole EMAS safety cam switch PSA025AK241E for two switched poles, 25A, position 0-1, 90 °, IP54, front frame 48 × 48mm.
Safety main cam switch EMAS PSA020AK941E for three phases and neutral wire (3P + N), 20A, switch 0-1 by 90 °, IP54, forehead 48 × 48mm.
Two-pole EMAS safety cam switch PSA032AK241E for two switched poles, 32A, position 0-1, 90 °, IP54, front frame 64 × 64mm.
Two-pole EMAS safety cam switch PSA040AK241E for two switched poles, 40A, position 0-1, 90 °, IP54, front frame 64 × 64mm.
Prices include the recycling fee.
This branch combines devices On/Off with a 90° rotation. When selecting, separate the operating control, the maintenance disconnection function, and the functional safety control. The term 'Safety' alone does not prove PL or SIL and does not confirm the specific insulation or disconnection property of each product. Each such request must be based on documentation of the exact implementation.
The offer includes EMAS PSA010AK141E, PSA016AK341E and PSA016AK941E. EMAS in PSA016AK341E presents On- Off for three phases, position 0-1, angle 90 °, forehead 48 × 48 mm and Ie 16 A in AC21A. Three electric paths and two control positions are not a contradiction: they are two different properties.
The specific designation is also important for any neutral pole, mechanical implementation, and method of installation. The presence of an additional pole does not say anything about the order of its operation. From the handle, it cannot be inferred whether it is lockable, positive disengagement, or a specific function for insulation. Required properties should be determined for the selected code, not just for the related series.
Pilz explains the functional safety assessment At the level of specific safety functions and related control parts. The required level is based on risk assessment. Using a component with a specific name or color is not a substitute for design and verification of the relevant function.
Operational shutdown can only cancel the machine request. Service disconnection addresses other issues, such as possible additional power, residual energy, or unwanted reactivation. Emergency stop is another separate request. These tasks cannot be combined with a single word 'shutdown' without specifying what the assembly actually ensures.
Consider a specific example: the device has a main electrical drive, a separately powered control interface, and pneumatic movement. The customer requests that position 0 stops normal operation. This does not imply that the interface is disconnected or that the compressed air energy is removed. A three-pole implementation cannot answer questions outside the paths it actually controls.
In the specification, separate three verifiable requests: canceling the operational command, determining the method of disconnecting electrical sources, and measures against unexpected movement. For each, it must be clear which part of the device fulfills it and how the function is verified. The example is not a valid safety concept or service manual.
When selecting electrically, do not classify AC21A as a universal motor category. Amps on the label cannot directly infer the allowed movement power. For the project, essential conditions for rotation, voltage, load, and its behavior during state change. Similarly, a plug switch does not automatically provide overcurrent or short-circuit protection.
The installation shall respect the manufacturer's design and the corresponding accessoriesThe compliance of the label, handle, and actual contact states is verified; electrical testing is not part of the appearance after installation. Network connections and safety measures should be handled by a professional.
The angle itself does not allow such a conclusion. Compare documented functions and parameters, not just a mechanical path. Alternative controls represent On / Off Switches 60 °.
First, describe the expected state of the device and its energy source. Vacuum cleaners.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.