Phone +420 774 723 123 Cart · 0 · empty

Accessories

Accessories for EMAS cam switches – enclosures, contact bodies and labels. Choose by switch series.

Filters
Found 4 products
IN STOCK

PSK12, EMAS, box for main switches, 3-4f 10A-25A

Cat. no.: PSK12

PSK12 EMAS - cabinet for cam switch. Technical specifications, use, assembly and selection of the correct variant.

In stock 5 or more pcs
6,94 €
excl. VAT · 8,40 € incl. VAT
IN STOCK

PSK21, EMAS, box for main switches, 1-2f 32A-40A

Cat. no.: PSK21

PSK21 EMAS - cabinet for cam switch. Technical specifications, use, assembly and selection of the correct variant.

In stock 5 or more pcs
7,30 €
excl. VAT · 8,84 € incl. VAT
IN STOCK

PSK22, EMAS, box for main switches, 3-4f 32A-40A

Cat. no.: PSK22

PSK22 EMAS - case for cam switch. Technical specifications, use, assembly and selection of the correct variant.

In stock 2 ks
7,62 €
excl. VAT · 9,22 € incl. VAT

PSK11, EMAS, box for main switches, 1-2f 10A-25A

Cat. no.: PSK11

PSK11 EMAS - case for cam switch. Technical specifications, use, assembly and selection of the correct variant.

On request
6,58 €
excl. VAT · 7,96 € incl. VAT

Prices include the recycling fee.

Accessories

The applicability of the solenoid starters determines whether the selected device actually fits into the assembly, whether it can be properly controlled, and whether it is possible to meet environmental requirements. The box is not an electrical substitute for another type of starter. Its selection therefore depends on the complete specification of the device, the contact body dimensions, and the mounting method.

EMAS PSK boxes and their destination

In the TECHNOLINE range, for example, you will find PSK11, PSK12, PSK21 and PSK22. EMAS distinguishes in the PSK series sizes for devices 10–25 A and 32–40 A and for different numbers of contact bodies. The number of bodies cannot be replaced by the number of control positions without a drawing. Two devices with the same current may require different space.

Specifically PSK12 manufacturer determines for 10-25 A and three to four bodies; specifies IP54 for this box. This does not prove the shielding of the final assembly with the starter and cable inputs. The assessment applies to the entire installation, not just the highest IP of some components.

Compatibility has several dimensions

First check if the manufacturer specifies the given combination of starter and box. Then compare the position of the locking, depth behind the body, and space for the contacts. Next, check the cable access: the cable can enter the enclosure, but it must have space for its allowed flex and slackening of the pull. The outer dimensions are not a substitute for usable internal space.

Besides geometry, consider the orientation of the label and handle. After installation, the marked positions must correspond to the actual function and be readable from the service area. The additional label 'main switch' or color change does not constitute a safety feature that the manufacturer did not specify. The applicability also does not increase the rated current.

Model example of the spatial reserve

Consider only the illustrative design: between the mounting plane and the inner wall, there is 95 mm. The body of the starter takes up 55 mm in this example, the designed space for cable routing 25 mm, and the mounting reserve 10 mm. The required depth is 55 + 25 + 10 = 90 mm, i.e., with a difference of 5 mm. The numbers are not the PSK12 dimensions or universal minimum spacing.

The result only means that one dimensional sum has been achieved. It has not verified the width, collision of weights with the passage, the curvature radius of the specific cable, or tool access. If the contact body is extended by 12 mm, the same design now requires 102 mm and does not comply. The same front switch can still be retained.

Installation and follow-up

For the finished assembly, specify the tightening conditions, used inputs, and unused openings. When changing the cable routing, check that you do not transfer the load to the contacts or mechanism. The box must allow the pre-defined installation and maintenance; a tight closure must not deform the starter. The actual connections and verification of electrical safety measures should be done by a professionally skilled person.

Frequently asked questions

Do I pick a box just by the number of phases?

No. You need the exact type, compatibility and spatial design. Current size and number of contact bodies are different selection aspects.

Same accessories for 60 ° and 90 °?

This cannot be expected without verification. Compare relevant On / Off Switches 60 ° and On / Off Safety switches 90 ° by code and drawing. Select the default function in the overview first Vacuum cleaners.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.