Step cam switches

EMAS step cam switches with positions 0–2 to 0–4 for switching stages step by step. Choose by number of positions and current.

Filters
Found 54 products
OUR TIP

PSA050KS127S, EMAS, Switch standard 0-1-2-3-4-5-6-7, number of poles 1, current 50A

Cat. no.: PSA050KS127S

PSA050KS127S EMAS - step cam switch, 400V AC, 50A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
89,53 €
excl. VAT · 108,33 € incl. VAT
OUR TIP

PSA080KS126S, EMAS, Standard switch 0-1-2-3-4-5-6, No. of poles 1, current 80A

Cat. no.: PSA080KS126S

PSA080KS126S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
94,67 €
excl. VAT · 114,55 € incl. VAT
OUR TIP

PSA063KS127S, EMAS, Standard switch 0-1-2-3-4-5-6-7, No. of poles 1, Current 63A

Cat. no.: PSA063KS127S

PSA063KS127S EMAS - step cam switch, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
96,19 €
excl. VAT · 116,39 € incl. VAT
OUR TIP

PSA080KS127S, EMAS, Standard switch 0-1-2-3-4-5-6-7, No. of poles 1, Current 80A

Cat. no.: PSA080KS127S

PSA080KS127S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
107,50 €
excl. VAT · 130,07 € incl. VAT

Prices include the recycling fee.

Step cam switches

The step motor is used to select several fixed states. Each step can represent another preset, but the step number itself does not determine whether a single circuit is selected or functions are added sequentially. For the correct selection, first describe the required contact combinations and then the number of steps.

Scope of elections on specific models

TECHNOLINE offers, for example, PSA016KS132S with 0-1-2 and PSA020KS134S with a range of 0-1-2- 3-4. EMAS confirms for PSA016KS132S One pole, angle 60 ° and Ie 16 A in AC21A. PSA020KS134S has according to the manufacturer one pole, four steps off zero, angle 60 ° and Ie 20 And in AC21A. Zero is counted into the number of stable positions: it is therefore three and five positions, not three and five poles.

Do not change the selection and sum program

The request 'step 3' can only mean the active third output. Other devices with the same label require simultaneously the first, second, and third step. These requirements lead to different contact programs. From the label KS alone or from the label photo, do not assume incomplete connections; the decisive is the diagram of the specific variant.

Also check the neighboring positions when transitioning to a more distant selection. Mechanical rotation across a step can cause a short change in the command, even though the operator does not intend to stop. The control must have a defined method to distinguish a change in selection from the confirmed request. Without such a specification, the number of steps is not a sufficient specification.

Model example of four presets

Imagine a test device where position 0 means no preset and positions 1 to 4 select programs A to D. We require only one active selection. The logical words for A/B/C/D therefore are 0000, 1000, 0100, 0010, and 0001. It is a functional assignment, not the publication of the schematic of a certain model.

If instead of this assignment, sequential addition of functions is required, step 3 could mean 1110 and step 4 1111. The number of positions would remain the same. This difference explains why it cannot be selected only by the range 0–4. When designing, follow also disabled combinations and the method of evaluating incomplete or erratic signals.

What to verify in installation

For direct torque operation, compare the appropriate category of use, operating voltage, and current. The numerical step is not a step of electrical power: position 4 does not mean four times the current load capacity. The motor's usability or inductive load cannot be deduced from the given amperes.

When using for control inputs, check small currents and the method of processing transitions. Check the clarity of the step number, the option to operate with gloves, and the actual space needed for rotation. On the panel, account for the contact body length and cable space; choose appropriate shielding between accessoriesThe connection of network circuits belongs to professional assembly.

Frequently asked questions

Is zero another power step?

Its electrical significance must be determined by the diagram; do not derive an insulating function from the digit.

Is a step switch always enough for three modes?

Not necessarily. If the assignment needs two options around the off center, compare Three-position switches 60 °General dimensioning can be found in the overview ball switches.