PSA010KS132S, EMAS, switch standard 0-1-2, number of poles 1, current 10A
PSA010KS132S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS step cam switches with positions 0–2 to 0–4 for switching stages step by step. Choose by number of positions and current.
PSA010KS132S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS132S EMAS - step cam switch, 400V AC, 16A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS132S EMAS - step cam switch, 400V AC, 20A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KS133S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS133S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025KS132S EMAS - step cam switch, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS133S EMAS - step cam switch, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KS134S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS134S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS134S EMAS - step cam switch, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KS135S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS135S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS135S EMAS - step cam switch, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KS127S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA040KS133S EMAS - step cam switch, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080KS132S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032KS132S EMAS - step cam switch, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025KS133S EMAS - step cam switch, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KS126S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS126S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS126S EMAS - step cam switch, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS127S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA032KS133S EMAS - step cam switch, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025KS134S EMAS - step cam switch, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS127S EMAS - step cam switch, 400V AC, 20A, IP54. Technical specifications, use, installation and selection of the correct variant.
Prices include the recycling fee.
The step motor is used to select several fixed states. Each step can represent another preset, but the step number itself does not determine whether a single circuit is selected or functions are added sequentially. For the correct selection, first describe the required contact combinations and then the number of steps.
TECHNOLINE offers, for example, PSA016KS132S with 0-1-2 and PSA020KS134S with a range of 0-1-2- 3-4. EMAS confirms for PSA016KS132S One pole, angle 60 ° and Ie 16 A in AC21A. PSA020KS134S has according to the manufacturer one pole, four steps off zero, angle 60 ° and Ie 20 And in AC21A. Zero is counted into the number of stable positions: it is therefore three and five positions, not three and five poles.
The request 'step 3' can only mean the active third output. Other devices with the same label require simultaneously the first, second, and third step. These requirements lead to different contact programs. From the label KS alone or from the label photo, do not assume incomplete connections; the decisive is the diagram of the specific variant.
Also check the neighboring positions when transitioning to a more distant selection. Mechanical rotation across a step can cause a short change in the command, even though the operator does not intend to stop. The control must have a defined method to distinguish a change in selection from the confirmed request. Without such a specification, the number of steps is not a sufficient specification.
Imagine a test device where position 0 means no preset and positions 1 to 4 select programs A to D. We require only one active selection. The logical words for A/B/C/D therefore are 0000, 1000, 0100, 0010, and 0001. It is a functional assignment, not the publication of the schematic of a certain model.
If instead of this assignment, sequential addition of functions is required, step 3 could mean 1110 and step 4 1111. The number of positions would remain the same. This difference explains why it cannot be selected only by the range 0–4. When designing, follow also disabled combinations and the method of evaluating incomplete or erratic signals.
For direct torque operation, compare the appropriate category of use, operating voltage, and current. The numerical step is not a step of electrical power: position 4 does not mean four times the current load capacity. The motor's usability or inductive load cannot be deduced from the given amperes.
When using for control inputs, check small currents and the method of processing transitions. Check the clarity of the step number, the option to operate with gloves, and the actual space needed for rotation. On the panel, account for the contact body length and cable space; choose appropriate shielding between accessoriesThe connection of network circuits belongs to professional assembly.
Its electrical significance must be determined by the diagram; do not derive an insulating function from the digit.
Not necessarily. If the assignment needs two options around the off center, compare Three-position switches 60 °General dimensioning can be found in the overview ball switches.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.