G4-1052, RELPOL, retaining clip
G4-1052 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Electromagnetic industrial relays, sockets and accessories for switching signals and smaller loads in control cabinets. Choose by coil voltage (AC/DC), number and rating of contacts and socket type.
G4-1052 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
RS2.M00.AC, EMAS: plastic retaining clip designed for mechanically securing a compatible relay in a socket of series RS2.
GZT80-0040 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
The QIANJI plug-in socket DYF14A is intended for 14-pin industrial relays with four changeover contacts. It allows the relay to be connected in a control cabinet and makes its possible replacement…
RS2.KY.01.DC EMAS – LED module with green LED and protective diode 6–24V DC. Key data: Value, RS2.KY.01.DC, LED module with protective diode. Exact technical data for selecting the relay accessory…
RELPOL socket GZT4B for connecting a R4N series plug-in relay in a control cabinet. It is intended for the fourteen-pin relay version with four changeover contacts.
M91G, RELPOL, indication and protection module for relay coils, 6–24VAC/DC, green LED. Module M91G indicates coil energisation with a green LED and limits voltage peaks when it is switched off.
M93G RELPOL – protection module for relays. Key data: 230 V AC. Exact technical data for selecting the relay accessory type.
RS2.RC.05 EMAS – LED module with green LED and protective diode 110-230V AC. Key data: Value, RS2.RC.05, LED module with protective diode. Exact technical data for selecting the relay accessory type.
RE2.U2C.DC024.S0, EMAS, power relay for PCB, 2 changeover contacts, coil 24VDC, 8A. Eight-pin relay of series RE2 U2C with two independent changeover contacts for soldering into a PCB or use with a…
RM84-2012-35-1012, RELPOL, miniature relay 2×CO, coil 12VDC, contacts 8A/250VAC AC-1. Relay RM84 with two changeover contacts and a 12VDC coil for switching control circuits.
RM84-2012-35-1024 RELPOL – electromagnetic relay, 24V DC, 2 changeover contacts, 12 A. Key data: RM 84, GZM80, 8 A / 250 VAC. Exact technical data for selecting the electromagnetic relay type.
HH54P QIANJI – electromagnetic relay, 24V DC, 4 changeover contacts, 5A. Key data: HH54P, DYF14A, 5 A / 24 VDC. Exact technical data for selecting the electromagnetic relay type.
ZG20-1 RELPOL – jumper comb for relays. Key data: 20, 35A. Exact technical data for selecting the relay accessory type.
ZG20-3 RELPOL – jumper comb for relays. Key data: 20, 35A. Exact technical data for selecting the relay accessory type.
RS2.M2CO.08V.S0, EMAS, DIN-rail relay socket for PCB relays RE2, 4/5/6/8 pins, 250VAC. Socket RS2.M2CO.08V.S0 is designed for DIN-rail mounting and for inserting suitable power relays RE2 with…
GZM80, RELPOL, plug-in socket for miniature relays, 2 changeover contacts, DIN. Relpol GZM80 is a compact screw socket for selected series of miniature relays RM84, RM85 and RM87L/RM87P.
GZT92, RELPOL: screw socket for DIN 35mm for relays RM87N and RM87N Sensitive, rated load 12A/300VAC.
GZT4, RELPOL, plug-in socket for relay R4N, 4 changeover contacts, DIN. Socket GZT4 is used for connecting four-pole industrial relays R4N and allows the relay to be replaced without disconnecting…
RM87N-2011-25-1024, RELPOL, miniature electromagnetic relay RM87N, 1CO, coil 24VDC, 12A. Miniature relay RM87N-2011-25-1024 has one changeover contact and a 24VDC. coil
RM87N-2011-35-1024, RELPOL, miniature electromagnetic relay RM87N, 1CO, coil 24VDC, 12A. Miniature relay RM87N-2011-35-1024 has one changeover contact and a 24VDC. coil
RE2.U2C.AC230.S0, EMAS: miniature relay for PCB mounting, coil 230VAC, two changeover contacts 2CO, rated current 8A.
RM84-2012-25-5230, RELPOL: miniature relay 2CO with coil 230VAC, contact load AC-1 8A/250VAC.
RM699BV-3011-85-1024, RELPOL, miniature relay 1×CO, coil 24VDC, contacts 6A/250VAC AC-1. Slim relay RM699BV in version 1×CO with a 24VDC coil for the interface between electronics and the switched…
R4N-2014-23-1024 RELPOL – electromagnetic relay, 24V DC, 4 changeover contacts, 12A. Key data: R4, GZT 4, 6 A / 24 VDC. Exact technical data for selecting the electromagnetic relay type.
Prices include the recycling fee.
Choose an electromagnetic relay as the interface between a command and a specific switched circuit. First determine whether you are designing a new control cabinet or replacing an existing part. For a new assembly, you need an electrical brief and installation space. For a replacement, also compare the complete order code, the socket version and the documentation of the original wiring.
The range includes the RM84, RM87N and R4N families as well as EMAS relays. For the switching element itself, open Relay, for its base Sockets and for add-ons Accessories. The guide Complete relays with socket explains the selection of the assembly. The breakdown helps prepare a parts list without automatically assuming what the pack contains.
For each required contact, write down its specific task. One may pass a command, another the state to the higher-level control system. The number of contacts then follows from the list of functions; do not start with the housing size. For contacts that are to change state simultaneously, also record the permissible time differences for the application.
OMRON explains a common monostable relay by the movement of the armature caused by the coil and the return of the spring after de-energisation. NO denotes a contact open in the rest state, NC a closed one. A changeover contact connects the common terminal alternately to these two branches.
RELPOL data sheet RM84 separates the loads AC1, AC15, DC1 and DC13. Do not transfer resistive load capacity to a solenoid. Likewise, do not confuse mechanical endurance with electrical endurance under a specific load.
When comparing two candidates, mark the documented value or missing documentation for each requirement. An empty row is a reason to complete the documentation before selection.
A model machine performs six complete on/off cycles per minute. Over eight hours of work, this is 6 × 60 × 8 = 2 880 cycles per day, and over 250 days 720 000 cycles per year. This is our own operating brief, not a parameter of the relay offered or a prediction of its service life.
Transfer the result to the requirement for verifying electrical endurance. Separately note manual adjustment and repeated start-ups that are absent from the normal cycle. If these activities are frequent, calculate their contribution from real operation. An exact number of cycles is more useful than a vague description of “occasional switching”.
In the rail layout, draw the position of the labels, supply wires and retaining clip. Verify that the relay can be identified even after the wiring is complete. Also enter the add-on module in the bill of materials if it is part of the design. A later replacement should be based on this assembly, not just on the cover colour or the number of pins.
In the case of occasional failure to pick up, record the relationship with the starting of other loads and with the heating of the control cabinet. OMRON's guidance on coils points out the influence of temperature and actual voltage on function. A professional check must work with the limits of the chosen type, not just with the voltage written on the power supply.
No. OMRON explains the uneven moment of contact closure; one of them may briefly carry the entire load. Do not add currents without explicit documentation from the manufacturer.
No. A safety function requires a documented design and assessment of the entire function. The number of NO and NC alone does not allow such a conclusion.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.