R4N-2014-23-5230-WT, RELPOL, industrial relay 4× changeover contact, coil 230VAC, 6A AC-1
R4N-2014-23-5230-WT, RELPOL: industrial relay with four changeover contacts 4CO and a 230VAC coil; contact current AC-1 6A.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Electromagnetic industrial relays, sockets and accessories for switching signals and smaller loads in control cabinets. Choose by coil voltage (AC/DC), number and rating of contacts and socket type.
R4N-2014-23-5230-WT, RELPOL: industrial relay with four changeover contacts 4CO and a 230VAC coil; contact current AC-1 6A.
RS1P11G1 EMAS – socket for 11-pin relay. Exact technical data for selecting the relay socket type.
PI6W-1P, RELPOL: feed-through socket with screw terminals for RM699BV and RSR30, width 6.2mm, DIN rail 35mm.
RE1P11DC024 EMAS – power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover. Exact technical data for selecting the electromagnetic relay type.
RE1P11AC220 EMAS – electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A. Key data: RS1P11G1. Exact technical data for selecting the electromagnetic relay type.
PIR6W-1P-230VAC/DC RELPOL – industrial relay, 230 V AC, 11, 12, 14. Exact technical data for selecting the electromagnetic relay type.
PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm. Relpol PIR6W-1P-24VAC/DC is an interface relay with a width of 6.2mm designed for signal and control circuits.
RM84-2012-25-1024, RELPOL: miniature relay 2CO with coil 24VDC, contact load AC-1 8A/250VAC.
Prices include the recycling fee.
Choose an electromagnetic relay as the interface between a command and a specific switched circuit. First determine whether you are designing a new control cabinet or replacing an existing part. For a new assembly, you need an electrical brief and installation space. For a replacement, also compare the complete order code, the socket version and the documentation of the original wiring.
The range includes the RM84, RM87N and R4N families as well as EMAS relays. For the switching element itself, open Relay, for its base Sockets and for add-ons Accessories. The guide Complete relays with socket explains the selection of the assembly. The breakdown helps prepare a parts list without automatically assuming what the pack contains.
For each required contact, write down its specific task. One may pass a command, another the state to the higher-level control system. The number of contacts then follows from the list of functions; do not start with the housing size. For contacts that are to change state simultaneously, also record the permissible time differences for the application.
OMRON explains a common monostable relay by the movement of the armature caused by the coil and the return of the spring after de-energisation. NO denotes a contact open in the rest state, NC a closed one. A changeover contact connects the common terminal alternately to these two branches.
RELPOL data sheet RM84 separates the loads AC1, AC15, DC1 and DC13. Do not transfer resistive load capacity to a solenoid. Likewise, do not confuse mechanical endurance with electrical endurance under a specific load.
When comparing two candidates, mark the documented value or missing documentation for each requirement. An empty row is a reason to complete the documentation before selection.
A model machine performs six complete on/off cycles per minute. Over eight hours of work, this is 6 × 60 × 8 = 2 880 cycles per day, and over 250 days 720 000 cycles per year. This is our own operating brief, not a parameter of the relay offered or a prediction of its service life.
Transfer the result to the requirement for verifying electrical endurance. Separately note manual adjustment and repeated start-ups that are absent from the normal cycle. If these activities are frequent, calculate their contribution from real operation. An exact number of cycles is more useful than a vague description of “occasional switching”.
In the rail layout, draw the position of the labels, supply wires and retaining clip. Verify that the relay can be identified even after the wiring is complete. Also enter the add-on module in the bill of materials if it is part of the design. A later replacement should be based on this assembly, not just on the cover colour or the number of pins.
In the case of occasional failure to pick up, record the relationship with the starting of other loads and with the heating of the control cabinet. OMRON's guidance on coils points out the influence of temperature and actual voltage on function. A professional check must work with the limits of the chosen type, not just with the voltage written on the power supply.
No. OMRON explains the uneven moment of contact closure; one of them may briefly carry the entire load. Do not add currents without explicit documentation from the manufacturer.
No. A safety function requires a documented design and assessment of the entire function. The number of NO and NC alone does not allow such a conclusion.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.