Blow gun

Blow guns for cleaning machines, parts and workstations with compressed air. Choose by nozzle length, connection and nozzle type.

Filters
Found 3 products
IN STOCK

TAG-A-S, TECHNOLINE, pneumatic blow gun with short nozzle, short nozzle approx. 10cm

Cat. no.: TAG-A-S

TAG-A-S, TECHNOLINE: pneumatic blow gun with short nozzle. short nozzle approx. 10cm. Use in pneumatic distribution and verified mounting criteria.

In stock 5 or more pcs
3,62 €
excl. VAT · 4,39 € incl. VAT
OUR TIP IN STOCK

TAG-A-L, TECHNOLINE, pneumatic blow gun with long nozzle, long nozzle approx. 30cm

Cat. no.: TAG-A-L

TAG-A-L, TECHNOLINE: pneumatic blow gun with long nozzle. long nozzle approx. 30cm. Use in pneumatic distribution and verified mounting criteria.

In stock 5 or more pcs
4,14 €
excl. VAT · 5,01 € incl. VAT
IN STOCK

DG-10, TECHNOLINE, metal pneumatic blow gun, metal version

Cat. no.: DG-10

DG-10, TECHNOLINE: metal pneumatic blow gun. metal version. Use in pneumatic distribution and verified mounting criteria.

In stock 5 or more pcs
7,25 €
excl. VAT · 8,77 € incl. VAT

Prices include the recycling fee.

Blow gun

A blow gun supplies compressed air to the place of cleaning. By pressing the trigger, the operator opens the flow and directs it with the nozzle onto the work surface. Pneuflex describes the use for removing small dirt and drying parts. The practical specification must determine what should remain clean after blow-off and where the removed material goes; merely moving dirt to an adjacent part is not a completed operation.

The range here includes TAG-A-S, TAG-A-L a DG-10. Before ordering, compare the complete delivery configuration, connection and documentation of the selected piece.

Selection by work operation

First mark on the workplace sketch the reach, blow-off direction and the place for storing the gun. During the test, observe whether the operator can reach all required surfaces without changing grip. Compare candidates on the same part, at the same distance and with the same cleaning objective. The record should include the length of each blow-off and the number of repetitions needed to complete the work.

Before comparing, determine the acceptance criterion: which surface you check, how you record the result and how many workpieces you assess. Keep the same evaluation method for all candidates. Attach a photo of the workplace and the test setting to the result so that it can be repeated later when the shift changes.

Assess flow rate and pressure together: an undersized supply can restrict the flow. The Silvent instructions therefore emphasise a suitable size of the supply paths. Request the operating limits for the selected gun; a general catalogue value does not replace the specification of the specific version.

Mounting and safe blow-off

Before connecting or disconnecting, close and depressurise the supply. Verify firm securing of the joints and the corresponding pressure and temperature limits of the connected components. Do not aim at persons, do not clean clothing or skin and do not block the outlet. Use eye protection and other protective equipment according to the workplace risks. Do not lock the trigger in the open position. These general rules are based on Silvent instructions, points 4.5–4.12 and 7.7–7.10; the technical parameters of its products are not transferred to the range here.

Our own air consumption model

Let us consider only a model flow rate of 180 l/min, expressed as a volume converted to explicitly chosen reference conditions of 1 bar absolute and 20 °C. We assume a constant flow during opening, a two-second blow-off and 120 operations per hour. The total opening time is 2 × 120 = 240 s, i.e. 4 minutes. Consumption is V = Q × t = 180 × 4 = 720 litres per hour under the stated reference conditions.

If each blow-off were shortened to one second, the same model would give 360 litres. However, the halved time must still ensure the required cleaning result. The calculation is not a TAG or DG-10 measurement and does not determine a suitable product. For an actual comparison, add the measured flow rate, its reference conditions and the working frequency; the compressor power consumption cannot be determined from these numbers alone.

Diagnostics and operating record

If cleaning deteriorates, repeat the original test and record the inlet pressure during blow-off, the opening time and the condition of the workpiece. Always change only one condition, for example the supply branch, and compare the result. This distinguishes a change of tool from a change of specification. In case of a trigger fault or damage, remove the gun from use and determine the repair procedure according to its instructions.

FAQ

Is it enough to select by extension length?

Verify the length by a reach test. Complete the decision with the connection, operating documentation and the result of the same cleaning operation; the dimension alone does not provide a complete specification.

Is blowing off work clothing permitted?

The Silvent instructions explicitly prohibit such use. To remove dirt from clothing, choose a procedure specified by the workplace that does not direct a compressed air jet at a person.