TPM04, TECHNOLINE, bulkhead push-in fitting, 2× tube outer Ø4mm, panel mounting
TPM04, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø4mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Bulkhead push-in fittings for passing a pneumatic tube through the wall of a cabinet or machine guard. Choose by tube diameter and panel thickness.
TPM04, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø4mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TPM06, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø6mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TPM08, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø8mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TPM10, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø10mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TPM12, TECHNOLINE: bulkhead push-in fitting. 2× tube outer Ø12mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TBPM04, TECHNOLINE: all-metal bulkhead push-in fitting. 2× tube outer Ø4mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TBPM06, TECHNOLINE: all-metal bulkhead push-in fitting. 2× tube outer Ø6mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TBPM08, TECHNOLINE: all-metal bulkhead push-in fitting. 2× tube outer Ø8mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TBPM10, TECHNOLINE: all-metal bulkhead push-in fitting. 2× tube outer Ø10mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
TBPM12, TECHNOLINE: all-metal bulkhead push-in fitting. 2× tube outer Ø12mm, panel mounting. Use in pneumatic distribution and verified mounting criteria.
Prices include the recycling fee.
Select bulkhead fittings together with the bulkhead design. You need to determine both line connections and the method of fixing the part in the structure. The public range includes Pneuflex versions and all-metal items marked BPM. When comparing, separate the tube size from the hole size; the panel design should not be based only on the number in the fitting name.
Pneuflex describes PM as a coaxial connection of two tubes through a panel. For BPM states nickel-plated brass and fixing by the opposite threaded part after pushing through the hole.
For your own selection sheet, record the bulkhead thickness, the available space on both sides and the required line position. Add the complete dimensional drawing of the selected part. The hole, the length of the mounting part and the tool space are different items of the specification. For an assembly with multiple pass-throughs, mark each line already in the panel design; later service needs to clearly identify which inner branch corresponds to the outer connection.
Our own practical question is: which side must be accessible when replacing the fitting and which when replacing the tube? Check the design even after adjacent parts are fitted. If you need to change direction immediately behind the panel, compare Elbow fittings. If the line only continues in one axis outside the bulkhead, the relevant ones are Straight fittings.
For a removable cover, also draw the service position of the panel. Mark which lines remain connected and which are disconnected before removal. Assess your own choice of pass-through together with this procedure: the part must be accessible in the position in which the intervention actually takes place. Keep the marking of the inner and outer side the same in the sketch, mounting list and service record.
Let us consider a model panel with four pass-throughs in a row. For each, the designer reserved a working envelope 18 mm wide and requires a gap of 8 mm between the envelopes. The centre spacing is therefore 18 + 8 = 26 mm. From the centre of the first to the centre of the last hole there are three spacings, i.e. 3 × 26 = 78 mm. With an edge reserve of 12 mm from both outer centres, the row needs a total of 78 + 12 + 12 = 102 mm of panel width. This is our own geometric model, not the actual nut dimension, recommended hole diameter or mounting spacing of the offered product.
Prepare the mounting for a safely secured affected section without pressure. For your own acceptance, first compare the hole spacing with the drawing and verify tool access on both sides. Then draw the final routing of the line. If tube sizes change, plan this function separately via Reducing fittings. The sketch must show which interface carries the medium and which holds the fitting in the panel.
Pneuflex for PM describes inserting the tube into the fitting and releasing it by pressing the collet. For your own accessibility check, go through the operation on both sides of the panel.
Divide your own service record into fixing in the bulkhead and line connection. Record movement of the body relative to the panel separately from a symptom at the tube. If the problem appeared after a change of guarding, also compare the new service access and the position of surrounding holders. When looking for the cause, change one circumstance and keep the branch marking. This way you can verify whether the intervention addresses a specific connection or just changes the whole surrounding arrangement.
Design the hole according to the drawing of the mounting part of the specific fitting. The line diameter is a different quantity and does not itself describe the method of fixing in the panel.
If you require tightness against water, dust or another environment, write it separately in the specification. Require confirmation for the complete pass-through and the actual panel.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.