MN1MUM8, EMAS, miniature limit switch, MN1, roller lever, 1 CO
MN1MUM8 EMAS – miniature limit switch, MN1, roller lever, 1 CO. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS MK1, MN1 and MN3 miniature limit switches for sensing positions in confined spaces. Choose by actuating element, housing material and contact.
MN1MUM8 EMAS – miniature limit switch, MN1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN3PUM9 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.
MN2MUM3 EMAS – miniature limit switch, MN2, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN3MUM8 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.
MN1PUM9U EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN3MUM3 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.
MN1MUM3 EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
Prices include the recycling fee.
A miniature limit switch helps to sense position in a small space, but a smaller housing alone does not solve mounting tolerance or the accuracy of the whole mechanism. In the design, allow space for the actuator, connectors or wires and their strain relief. Body dimensions without the lever and connection may significantly underestimate the actual space required in the equipment.
This branch includes, for example, EMAS MK1PUP1, MK1KIM1, MK1MIP1 and models MN1. The MK1 series includes direct plungers, levers and roller variants; the specific selection is confirmed by the EMAS MK1 manufacturer's overview. The category also contains accessories, for example the terminal cover MN1YKAP, which must not be mistaken for a complete switch.
For MK1MIP1 the manufacturer states a short lever with a plastic roller, contact 1CO, protection IP20 and connection terminals 6.3 × 0.8 mm. See technical data MK1MIP1. The designation 1CO indicates one changeover contact with a common path, not two independent insulated circuits. Its electrical use must correspond to the actual circuit diagram.
Separate subcategories make it possible to compare Plastic Limit Switches MK1, Plastic Limit Switches MN1 and Metal Limit Switches MN3. Always verify the corresponding mechanical dimensions, actuation and terminals against the complete order code.
For the design, you need the position of the first switching, the available further travel and the release position separately. Repeatability describes the scatter of the switching position on repeated actuation; this quantity is defined by the OMRON glossary. A long lever need not have the same movement transmission as a direct plunger, so their data cannot be interchanged without assessing the geometry.
The switch should not be actuated at the limit where vibration alternately activates and releases the contact. At the same time, it cannot be pushed further without limit to gain a larger reserve. The direction of force, approach speed and operating range are chosen according to the specific version. For the electrical input, also check the minimum load and the required signal processing time.
Consider five model measurements of the switching position: 10.12; 10.16; 10.10; 10.14 and 10.18 mm. The range between the largest and smallest value is 0.08 mm. The mean is 10.14 mm. If the design requires a nominal point of 10.00 mm, the mean offset is 0.14 mm, even though the individual results lie relatively close together.
This is the author's demonstration of evaluating measurements, not the accuracy of MK1 or MN1. products. Moreover, five measurements are not enough for a general guarantee of accuracy throughout operation. The same approach direction, temperature, speed and mounting must be observed. A bracket offset can be corrected during adjustment, but this does not automatically remove unstable play in the mechanism.
Small terminals must not transmit force from a heavy or tensioned bundle. Protect the connection according to the environment of the entire installation and check that the connector or insulating sleeve does not restrict the lever. A terminal cover alone does not prove the watertightness of the whole assembly. For a more enclosed design, compare Plastic Limit Switches IP65; other principles can be found in the overview Limit Switches.
During the test, also observe the return to the initial position after the cam is removed. A wire resting on the lever or an unsuitably placed cover may change its mechanical response. Such an obstruction cannot be remedied just by changing the filter in the program.
No. Check the actuator position, operating travel, electrical function and terminals. A replacement of the same size may switch at a different point.
No. A changeover function with a common contact is not proof of independence or safety suitability of two channels.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.