Phone +420 774 723 123 Cart · 0 · empty

Accessories

Accessories for EMA pressure sensors – adapters and seals for the process connection. Check the threads on both sides.

Filters
Found 2 products
OUR TIP IN STOCK

US0004, adapter for pressure sensors, EMA ELECTRONIC

Cat. no.: US0004

US0004, adapter G1/4" to G1/2" for pressure sensors, EMA ELECTRONIC

In stock 5 or more pcs
7,74 €
excl. VAT · 9,36 € incl. VAT
OUR TIP IN STOCK

US0005, adapter for pressure sensors, EMA ELECTRONIC

Cat. no.: US0005

US0005, adapter G1/4" to G1/4" for pressure sensors, EMA ELECTRONIC

In stock 5 or more pcs
7,74 €
excl. VAT · 9,36 € incl. VAT

Prices include the recycling fee.

Accessories

This category belongs to EMA pressure sensors and contains mechanical adapters for their process connection. When choosing, you are solving the joint between the sensor and the measuring point: threads, seating surfaces, seals and space for mounting. The correct adapter must suit the entire assembly; matching one nominal size is not sufficient basis for an order.

US0004 and US0005 in this range

In the public listing, US0004 is described as an adapter from G1/4 to G1/2 and US0005 as G1/4 to G1/4. The second designation therefore does not mean that the part has no function. In addition to the thread size, its internal or external design, length and seating method must be compared. An incomplete verbal description of these two sizes does not replace a dimensional drawing.

When replacing, identify both counterparts and request verification of the specific mechanical connection. Also mark the position of the seating surfaces in the sketch. If the original assembly contained another intermediate piece, it must not be lost when ordering just because it resembled part of the sensor in the photograph.

Thread and seal are two parts of the design

The manufacturer WIKA distinguishes between parallel G threads and tapered NPT threads. With the G connection described, the seal is made on the corresponding seating surface, not merely by tightening the thread flanks. The same fraction in the name of different thread systems is therefore not confirmation of interchangeability. The seal material and the shape of the counterpart must match the specific joint.

WIKA's general information serves to explain the principle; it is not a mounting instruction or approval of the compatibility of EMA parts. Tightening torque, temperature limits and pressure load must be based on the documentation of the assembly actually used. Therefore add the medium, temperature and highest expected pressure including transients to the order.

Author's example: space around the adapter

Imagine an assembly drawing according to which the sensor has a height of 62 mm from the seating plane and the adapter assembly adds 18 mm. For fitting and disconnecting the connector, the project reserves another 25 mm. The required space is 62 + 18 + 25 = 105 mm. Under a cover with a clear height of 95 mm, 10 mm is missing, even though the threads may be correctly chosen.

The dimensions are the author's and do not belong to US0004 or US0005. The calculation is a reminder that service movement and the cable also belong in the assembly design. It is not enough to verify only whether the disconnected sensor fits into the opening. After changing the adapter, check the entire installation again.

Mounting and check after assembly

Before disconnecting, secure the process and depressurise the measuring point. Check cleanliness, damage to threads and the condition of the sealing surfaces. Prepare the correct counterpart and the specified seal so that mounting does not require additional improvisation. Tighten the assembly by the prescribed surfaces; neither the electrical body nor the cable should serve as a mounting lever.

After commissioning, record the result of the tightness check, the parts fitted and the procedure used. In the event of a subsequent fault, it is then possible to distinguish a part mix-up from damage or incorrect assembly. Sensor selection is offered by Simple pressure sensors; the series context is provided by EMA pressure sensors.

FAQ

Does an adapter increase the permissible pressure of the sensor?

No. Adding another part does not create a higher documented resistance of the original sensor.

Is a photograph enough for selection?

A photograph can help with identification, but it does not prove the exact thread, sealing geometry or permitted operating conditions.