Pressure sensor, thread G1/4", for pressure 250 bar, output 4-20mA, PB1119
Pressure sensor, thread G1/4", for pressure 250 bar, output 4-20mA, PB1120
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Simple EMA pressure sensors with 4–20 mA or 0–10 V analogue output. Choose by range, connection and output.
Pressure sensor, thread G1/4", for pressure 250 bar, output 4-20mA, PB1120
Pressure sensor, thread G1/4", for pressure 400 bar, output 4-20mA, PB1115
Pressure sensor, thread G1/2", for pressure 100 bar, output 0-10V, 2PB1112
Pressure sensor, thread G1/2", for pressure 200 bar, output 0-10V, 2PB1114
Pressure sensor, thread G1/2", for pressure 250 bar, output 0-10V, 2PB1120
Pressure sensor, thread G1/2", for pressure 400 bar, output 0-10V, 2PB1116
Pressure sensor, thread G1/2", for pressure 100 bar, output 4-20mA, 2PB1111
Pressure sensor, thread G1/2", for pressure 200 bar, output 4-20mA, 2PB1113
Pressure sensor, thread G1/2", for pressure 250 bar, output 4-20mA, 2PB1120
Pressure sensor, thread G1/2", for pressure 400 bar, output 4-20mA, 2PB1115
Pressure sensor, thread G1/4", for pressure 600 bar, output 0-10V, PB1118
Pressure sensor, thread G1/4", for pressure 600 bar, output 4-20mA, PB1117
Pressure sensor, thread G1/2", for pressure 600 bar, output 0-10V, 2PB1118
Pressure sensor, thread G1/2", for pressure 600 bar, output 4-20mA, 2PB1117
Prices include the recycling fee.
A simple pressure transmitter provides an electrical signal corresponding to pressure and leaves its interpretation to the connected device. When choosing, therefore, assess the entire chain: sensor, supply, cable, analogue input and conversion to engineering units. An error in the last step can create a plausible-looking reading even though the mechanical and electrical parts work correctly.
The EMA range includes, for example, PB1101, PB1102, 2PB1101 and 2PB1102. The listing distinguishes current and voltage variants as well as process threads. According to the product sheet of PB1101 this specific model has a 4 to 20 mA current output and a 8 to 36 V DC supply. The pin assignments or supply of other similarly designated models must not be derived from these values.
The control input must be set to the same type of signal that the transmitter provides. With a current loop, the sum of loads and the available voltage are also checked. With a voltage output, the input resistance and the common potential connection matter. General electrical conditions are always verified according to the diagram of the respective variant, not according to the number of connector contacts.
Request the permissible output load for the selected supply and connected input. Calculating the voltage reserve does not replace other limitations stated by the manufacturer. It is equally important to decide how the control system will detect disconnection, an incorrect range or an input fault. The presence of a 4 to 20 mA signal alone does not determine uniform fault currents for all products.
Consider a general two-wire loop with a 24 V supply. The model transmitter requires at least 10 V, the input has a resistance of 250 ohms and the sum of cable resistances is 50 ohms. At a current of 20 mA, the drop across the external load is 0.020 × (250 + 50) = 6 V. 18 V remains at the transmitter, i.e. a model reserve of 8 V above its requirement.
If the supply dropped to 15 V, only 9 V would remain under the same assumptions and the condition would not be met. The numbers do not describe PB1101 or any other version sold here. In addition to this calculation, the actual loop must also meet the maximum load and wiring specified by the manufacturer.
Enter the lower and upper values of the electrical signal and the corresponding pressure limits in the program. Carry out the check at several points; one point may happen to come out correctly even with an incorrect range. In addition to the resulting pressure, also record the electrical value itself during the test. This makes it easier to distinguish a sensor fault from a setting or display error.
Mount the mechanical part after securing and depressurising the measuring point. Check the thread, sealing surface, wrench accessibility and cable strain relief. After pressure is restored, check tightness and the stability of the reading. If you move the sensor, keep the information about the tapping point in the documentation; the new point may not represent the same operating state.
An overview of the series and range selection is provided by EMA pressure sensors. For mechanical connections, use pressure Accessories.
Only with a designed and verified conversion that respects the documentation of both parts. A random connection is not a compatibility test.
Not always. First verify the validity of the signal, the range configuration and the way the program displays a fault state.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.