US0004, adapter for pressure sensors, EMA ELECTRONIC
US0004, adapter G1/4" to G1/2" for pressure sensors, EMA ELECTRONIC
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMA pressure sensors with analogue output for liquids and gases. Choose by pressure range, medium, process connection and output.
US0004, adapter G1/4" to G1/2" for pressure sensors, EMA ELECTRONIC
US0005, adapter G1/4" to G1/4" for pressure sensors, EMA ELECTRONIC
smart programmable pressure sensor with user pressure setting, pressure range: 0-2 bar, offers 4 pressure units: bar, MPa, psi and kg/cm3, simple and practical design without the need for…
Pressure sensor, thread G1/4", for pressure 2 bar, output 4-20mA, PB1101
Pressure sensor, thread G1/4", for pressure 2 bar, output 0-10V, PB1102
Pressure sensor, thread G1/4", for pressure 5 bar, output 0-10V, PB1104
Pressure sensor, thread G1/4", for pressure 10 bar, output 0-10V, PB1106
Pressure sensor, thread G1/4", for pressure 20 bar, output 0-10V, PB1108
Pressure sensor, thread G1/4", for pressure 50 bar, output 0-10V, PB1110
Pressure sensor, thread G1/4", for pressure 400 bar, output 0-10V, PB1116
Pressure sensor, thread G1/4", for pressure 5 bar, output 4-20mA, PB1103
Pressure sensor, thread G1/4", for pressure 20 bar, output 4-20mA, PB1107
Pressure sensor, thread G1/4", for pressure 50 bar, output 4-20mA, PB1109
Pressure sensor, thread G1/2", for pressure 2 bar, output 4-20mA, 2PB1101
Pressure sensor, thread G1/2", for pressure 2 bar, output 0-10V, 2PB1102
Pressure sensor, thread G1/2", for pressure 5 bar, output 0-10V, 2PB1104
Pressure sensor, thread G1/2", for pressure 10 bar, output 0-10V, 2PB1106
Pressure sensor, thread G1/2", for pressure 20 bar, output 0-10V, 2PB1108
Pressure sensor, thread G1/2", for pressure 50 bar, output 0-10V, 2PB1110
Pressure sensor, thread G1/2", for pressure 5 bar, output 4-20mA, 2PB1103
pressure sensor; thread: G1/2"; for pressure 20 bar; output: 4-20mA; Ema Elecronic
Pressure sensor, thread G1/2", for pressure 50 bar, output 4-20mA, 2PB1109
Pressure sensor, thread G1/4", for pressure 100 bar, output 0-10V, PB1112
Pressure sensor, thread G1/4", for pressure 200 bar, output 0-10V, PB1114
Pressure sensor, thread G1/4", for pressure 250 bar, output 0-10V, PB1120
Prices include the recycling fee.
Choose an EMA pressure sensor as part of a specific measuring point. The normal pressure, short-term peaks, properties of the medium and the signal required by the control input are important. When replacing an older device, therefore, do not rely on an identical housing appearance. Record the complete code, connection designation and evaluation method; it is precisely this combination that determines what the new device must meet.
The range here includes PB and 2PB analogue transmitters and accessories US0004 and US0005. To select a specific transmitter, continue to Simple pressure sensors. Mechanical connections are addressed by pressure Accessories. Split the order into the measuring device, mechanical parts and electrical connection so that a verified counterpart is not missing during mounting.
WIKA distinguishes between measuring range, overload and burst pressure. The burst limit is not a permissible working pressure. In the specification, therefore, also state events during valve closure, pump start-up and depressurisation, not just the value monitored during steady operation. The specific limit for EMA must be determined by the corresponding product sheet.
An excessively wide range can be a disadvantage if the significant deviation is specified as a percentage of its full-scale value. Conversely, an excessively narrow range may not cover actual operation. Therefore base the decision on the required resolution of changes and documented load limits. The error in bar cannot be calculated from the expression "accuracy in percent" without stating the basis.
Let us compare two model devices with ranges of 0 to 10 bar and 0 to 100 bar. For the example, assign both a deviation of ±0.5 % of full scale. The first corresponds to ±0.05 bar, the second to ±0.50 bar. At a measured pressure of 2 bar, this is 2.5 % and 25 % of the value currently measured, respectively.
These deviations are not parameters of EMA products. The calculation only shows the significance of the selected range. The actual uncertainty may include other influences, and when comparing catalogues it is necessary to distinguish linearity, repeatability, temperature influence and the method of determining the resulting deviation.
Check all wetted materials, not just the visible metal of the connection. WIKA also includes seals among wetted parts; their suitability may be decisive for a specific liquid. The resistance of the housing to the environment is assessed separately from the chemical and thermal suitability of the process connection.
Before mounting, record the tapping location, device orientation and the required service space. Make the connection after depressurising and securing the process. After installation, verify tightness and compare the reading with a reference in several operating states. If short peaks appear, first determine their origin; smoothing the display alone does not prove that the mechanical stress on the measuring point has disappeared.
For maintenance, keep the set input range, units and the acceptance report. Future replacement can then be based on documented requirements, not on memory of the last display value.
No. Compare the exact range, pressure reference system, output, connection and operating conditions.
A mechanical adapter alone does not convert the range. It enables a specific connection, whose suitability and limit conditions must be verified separately.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.