Phone +420 774 723 123 Cart · 0 · empty

EMAS Motor Protection (Motor Starters)

EMAS MKS1TM motor starters for protecting motors against overload and short circuit. Choose by current setting range and auxiliary contacts.

Filters
Found 16 products
OUR TIP IN STOCK

MKS1-YKD01, EMAS, auxiliary contact for MKS motor starters, 1×NO+1×NC

Cat. no.: MKS1-YKD01

MKS1-YKD01, EMAS – auxiliary contact for MKS motor starters, 1×NO+1×NC. Contacts 1NO+1NC; separate MKS series accessory. Sold separately per 1ks, without motor starter.

In stock 5 or more pcs
4,09 €
excl. VAT · 4,95 € incl. VAT
OUR TIP IN STOCK

MKS1-E30, EMAS, emergency operating attachment for motor starter, red mushroom push button Ø30mm, twist-to-release

Cat. no.: MKS1-E30

MKS1-E30, EMAS, separate emergency operating attachment with mushroom push button Ø30mm, latching and twist-to-release. Sold per 1ks without starter and box.

In stock 5 or more pcs
4,09 €
excl. VAT · 4,95 € incl. VAT
OUR TIP IN STOCK

MKS1-K, EMAS, mounting box

Cat. no.: MKS1-K

MKS1-K EMAS – mounting box. Key data: plastic. Exact technical data for selecting the motor starter type.

In stock 5 or more pcs
6,14 €
excl. VAT · 7,43 € incl. VAT
OUR TIP IN STOCK

MKS1TM-0.16, EMAS, MKS motor starter, adjustable thermal protection 0.10–0.16A

Cat. no.: MKS1TM-0.16

MKS1TM-0.16, EMAS: motor protection switch with thermal protection setting 0.10–0.16A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-0.25, EMAS, MKS motor starter, adjustable thermal protection 0.16–0.25A

Cat. no.: MKS1TM-0.25

MKS1TM-0.25, EMAS: motor protection switch with thermal protection setting 0.16–0.25A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 4 ks
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-0.40, EMAS, MKS motor starter, adjustable thermal protection 0.25–0.40A

Cat. no.: MKS1TM-0.40

MKS1TM-0.40, EMAS: motor protection switch with thermal protection setting 0.25–0.40A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-20, EMAS, MKS motor starter, adjustable thermal protection 16.0–20.0A

Cat. no.: MKS1TM-20

MKS1TM-20, EMAS: motor protection switch with thermal protection setting 16.0–20.0A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 4 ks
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-25, EMAS, MKS motor starter, adjustable thermal protection 20.0–25.0A

Cat. no.: MKS1TM-25

MKS1TM-25, EMAS: motor protection switch with thermal protection setting 20.0–25.0A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-0.63, EMAS, MKS motor starter, adjustable thermal protection 0.40–0.63A

Cat. no.: MKS1TM-0.63

MKS1TM-0.63, EMAS: motor protection switch with thermal protection setting 0.40–0.63A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-1, EMAS, MKS motor starter, adjustable thermal protection 0.63–1.00A

Cat. no.: MKS1TM-1

MKS1TM-1, EMAS: motor protection switch with thermal protection setting 0.63–1.00A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-1.6, EMAS, MKS motor starter, adjustable thermal protection 1.00–1.60A

Cat. no.: MKS1TM-1.6

MKS1TM-1.6, EMAS: motor protection switch with thermal protection setting 1.00–1.60A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-2.5, EMAS, MKS motor starter, adjustable thermal protection 1.60–2.50A

Cat. no.: MKS1TM-2.5

MKS1TM-2.5, EMAS: motor protection switch with thermal protection setting 1.60–2.50A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-4, EMAS, MKS motor starter, adjustable thermal protection 2.50–4.00A

Cat. no.: MKS1TM-4

MKS1TM-4, EMAS: motor protection switch with thermal protection setting 2.50–4.00A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-6.3, EMAS, MKS motor starter, adjustable thermal protection 4.00–6.30A

Cat. no.: MKS1TM-6.3

MKS1TM-6.3, EMAS: motor protection switch with thermal protection setting 4.00–6.30A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 5 or more pcs
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-10, EMAS, MKS motor starter, adjustable thermal protection 6.30–10.0A

Cat. no.: MKS1TM-10

MKS1TM-10, EMAS: motor protection switch with thermal protection setting 6.30–10.0A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 4 ks
18,43 €
excl. VAT · 22,30 € incl. VAT
OUR TIP IN STOCK

MKS1TM-16, EMAS, MKS motor starter, adjustable thermal protection 10.0–16.0A

Cat. no.: MKS1TM-16

MKS1TM-16, EMAS: motor protection switch with thermal protection setting 10.0–16.0A. Combined thermal and magnetic protection, DIN mounting 35mm.

In stock 4 ks
18,43 €
excl. VAT · 22,30 € incl. VAT

Prices include the recycling fee.

Motor protection (motor starters) EMAS

Select EMAS motor starters of the MKS1TM series primarily according to the adjustable current range of the specific version. The category also includes accessories, such as auxiliary contact MKS1-YKD01 and mounting box MKS1-K. The protective device, signalling contact and empty box perform different functions; when putting together an order you therefore need to know not only the series but also the purpose of each part.

What thermal-magnetic protection provides

The thermal part responds to overload according to the time-current characteristic, the magnetic part to high fault current. These responses must not be confused: exceeding the set value does not mean immediate tripping on every short start. The general division of protective and control functions is summarised in ABB overview of motor starters; always verify the specific tripping characteristic for the selected EMAS device.

For regular remote commands, a contactor may also be part of the designed feeder. The starter then cannot be selected in isolation from the control method, upstream protection and the behaviour of the motor in the event of a fault. The differences between devices are summarised in the parent category Contactors and motor protection.

The setting range matters more than the family number

For MKS1TM-10 the manufacturer states a thermal setting range of 6.30–10.0 A and mounting on a 35 mm DIN rail. For a different suffix, its own data sheet must be used. The basis for this example is EMAS MKS1TM-10 data sheet. Compare the current range with the rated-plate current of the motor for the intended operating conditions, not just with its power in kW.

For longer run-up times, check the characteristic, the starting load and the repetition frequency. If the protection trips, distinguish between overload, a starting problem and another fault. Raising the setting without this assessment may remove the symptom but at the same time impair motor protection. The specific setting must be determined by a professional design.

Accessories and mounting space

MKS1-YKD01 is an add-on contact with a 1 NO + 1 NC combination; MKS1-K is an empty plastic box. The manufacturer lists them in the overview of MKS series accessories. The box is not a complete fitted starter. The auxiliary contact, in turn, does not extend the current range of the main poles and is not meant to replace power switching.

In the control cabinet design, leave space for accessories, access to the controls and the necessary cable routing. Verify the specific mechanical combination and fixing method. Assess the environment of the whole assembly including cable glands; the properties of the box alone cannot be transferred to the finished installation without further consideration.

Model example of preliminary selection

Suppose a motor whose rated-plate current for the selected duty is 8.2 A. In terms of the range alone, it falls within MKS1TM-10. The variant ending at 6.3 A does not cover this current; conversely, a device with a lower limit of 10 A is not a suitable replacement just because it is “stronger”. This is only a first range check, not an instruction for setting or wiring.

The second assessment must include starting and the prospective short-circuit current. The third verifies the contactor, accessories and installation conditions. If one of these steps fails, the correct current range alone does not confirm the complete assembly. For downstream switching, you can choose from the category Contactors and auxiliary contacts; mutual coordination must be documented for the specific combination.

FAQ

Can I switch the protection back on repeatedly after it trips?

Operation may only be restored after the cause has been clarified and the condition of the equipment assessed. Repeated resetting is not diagnostics and may not eliminate overload, a blocked drive or a supply fault.

Is the figure in amps enough to compare two starters?

No. Distinguish the adjustable range, the short-circuit breaking capacity at the given voltage, the characteristic and the accessories. Moreover, the contactor current rating in AC-3 is not a thermal protection setting.