L52, EMAS, L52, limit switch body, metal body, IP65
L52 EMAS – limit switch body, L52, IP65. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS L52 metal limit switches with direct plunger or roller actuation. Choose by head and contacts.
L52 EMAS – limit switch body, L52, IP65. Technical parameters, application and compatibility check.
L52K23SOP101 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K13REM121 EMAS – limit switch, L52, whisker, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13PUM211 EMAS – limit switch, L52, direct plunger, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13SOM101 EMAS – limit switch, L52, spring lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K23MIM311 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K23PUM211 EMAS – limit switch, L52, direct plunger, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K23SOM102 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K23SOM103 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K13SOM102 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13SOM103 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13SOP101 EMAS – limit switch, L52, spring rod, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K23MIM411 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K23MUM331 EMAS – limit switch, L52, roller plunger, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K13MUM331 EMAS – limit switch, L52, roller plunger, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13MIP411 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13MIP311 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13MIM311 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13MIM411 EMAS – limit switch, L52, one-way roller lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K13MEM121 EMAS – limit switch, L52, two-way roller lever, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K25PUM211 EMAS – limit switch, L52, direct plunger, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K25SOM102 EMAS – limit switch, L52, spring rod, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K25SOP101 EMAS – limit switch, L52, spring rod, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K27SOP101 EMAS – limit switch, L52, spring rod, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.
L52K23MEM122 EMAS – limit switch, L52, adjustable two-way roller lever, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
Prices include the recycling fee.
With the L52 series, assess the approach mechanism and the required length of the electrical signal together. The machine can press the switch correctly but, with a short pass, create information that the downstream control does not capture as required. The design therefore needs not only the switching position but also the contact behaviour on arrival, dwell and departure of the cam.
The public range includes L52K23MUM331. A separate EMAS sheet confirms a metal plunger actuator with a roller of 13 mm and slow-action contacts 1NO + 1NC. The roller diameter is neither the permitted travel nor the length of the working approach.
For selection, draw the cam profile in the direction of movement. Determine the ramp section, any flat working surface and the run-out. Also check the contact width so that the cam does not act outside the intended part of the roller. When replacing the switch, also copy the bracket position and cam distance from the original installation; the code alone may not explain the earlier setting.
Your own design sheet can contain three rows of speeds: slowest, usual and fastest. Assign the expected signal length and the requirement of the downstream input to each. This procedure helps reveal a problem that does not show up during slow manual turning. Do not confuse the duration of mechanical pressing with the guaranteed time of stable contact.
Consider a practice cam whose flat working part is 24 mm long. At a speed of 0.30 m/s, i.e. 300 mm/s, passing this part takes 24 / 300 = 0.080 s, or 80 ms. If the speed is doubled, the time is reduced to 40 ms.
If the design specifies a required window of 50 ms for the model input, the second speed does not meet this preliminary condition. However, the calculation does not include contact rise, electrical transitions or detailed input behaviour. The figures are the author's own; 50 ms is not a property of any listed switch or control unit.
The conclusion for the design is: first verify the timing requirements of the actual control, then the cam profile and finally the real signal. Merely shifting the switch along the path changes the moment of the event but does not by itself lengthen the flat working surface. This difference is important when looking for occasional detection failures.
The working test should include the actual speed and load. This general procedure is recommended by OMRON guidelines for limit switches. For the specific L52 respect its drawing and specified limits; numerical recommendations of another brand do not carry over automatically.
After adjustment, record the switching and release positions and the test conditions used. During maintenance, compare the cam profile with the original condition. Local wear, bracket displacement or a change in movement guidance are easier to find if you have the original photo and dimensions.
No. The name describes the contact mechanism. Permitted speeds and actuation frequency must be determined by the documentation of the specific version.
Such a test only confirms a partial state. It does not check the timing or the entire approach during operation.
For lever geometry, compare Metal Limit Switches L51. Another metal design variant can be found in the category Metal Limit Switches L53.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.