MK1PUP1, EMAS, microswitch, MK1, plunger, 1 CO
MK1PUP1 EMAS – microswitch, MK1, plunger, 1 CO. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS limit and position switches for sensing positions of machines and mechanisms – plastic and metal, miniature, cross, safety and magnetic. Choose by actuator head (plunger, roller, lever), contacts, degree of protection and mounting.
MK1PUP1 EMAS – microswitch, MK1, plunger, 1 CO. Technical parameters, application and compatibility check.
TE-BS1012E EMAS – snap-action switch with bracket for control cabinet door sensing, plunger, 1 NO + 1 NC, snap action. Technical parameters, application and compatibility check.
MK1KIM1 EMAS – microswitch, MK1, lever, 1 CO. Technical parameters, application and compatibility check.
MK1KIM2 EMAS – microswitch, MK1, lever, 1 CO. Technical parameters, application and compatibility check.
MK1KIM3 EMAS – microswitch, MK1, lever, 1 CO. Technical parameters, application and compatibility check.
MK1KIM4 EMAS – microswitch, MK1, lever, 1 CO. Technical parameters, application and compatibility check.
MK1KIM5 EMAS – microswitch, MK1, lever, 1 CO. Technical parameters, application and compatibility check.
MK1MIM1 EMAS – microswitch, MK1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MK1MIM2 EMAS – microswitch, MK1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MK1MIP1 EMAS – microswitch, MK1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MK1MIP3 EMAS – microswitch, MK1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MK1PUP1Y EMAS – microswitch, MK1, plunger, 1 CO. Technical parameters, application and compatibility check.
MN1PUM1 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
LD33MEL122 EMAS – limit switch actuator head / actuator. Technical parameters, application and compatibility check.
MN1KIM1 EMAS – miniature limit switch, MN1, lever, 1 CO. Technical parameters, application and compatibility check.
MN1KIM2 EMAS – miniature limit switch, MN1, lever, 1 CO. Technical parameters, application and compatibility check.
MN1PUM7 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
LD51MEM123 EMAS – limit switch actuator head / actuator. Technical parameters, application and compatibility check.
MN2MIM1 EMAS – miniature limit switch, MN2, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN1MIM1 EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
MN1MIM2 EMAS – miniature limit switch, MN1, roller lever, 1 CO. Technical parameters, application and compatibility check.
MN1MIM1Y EMAS – miniature limit switch, MN1, 1 CO. Technical parameters, application and compatibility check.
MN1PUM3 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
MN1PUM9 EMAS – miniature limit switch, MN1, direct plunger, 1 CO. Technical parameters, application and compatibility check.
LK20K25 EMAS – limit switch contact block, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
Prices include the recycling fee.
A limit switch converts the reaching of a certain position into electrical information. In the mechanical version, a moving part of the machine acts on a plunger, roller, lever or other actuator. The magnetic door version, on the other hand, works with a matching counterpart without mechanical pressing. The right selection begins with a description of the movement and the meaning of the signal: do you need to confirm a position, start the next process step, or create part of a safety function? These tasks may require different solutions, even if the mounting location looks similar at first glance.
A direct plunger requires correct guidance of force; a lateral approach outside the specified direction may stress the mechanism differently than the design assumes. A roller works with a ramp surface whose shape determines the course of pressing and release. With a lever, also assess the length setting and the space during the return movement. A flexible whisker is not a substitute for any position tolerance: it still has defined directions and limits of actuation.
According to EMAS, the specific L5K13MEM123 has a plastic body, an adjustable lever with a metal roller of 18 mm and snap-action contacts 1NO + 1NC. It is an example of why the housing and actuator materials are assessed separately. See technical sheet L5K13MEM123.
A snap-action mechanism changes the contact state abruptly once a certain actuator position is reached. Slow action, by contrast, follows the actuator movement more closely. Neither name by itself proves positive opening. That is a documented design feature in which the mechanical force of the actuator directly separates the contacts under specified conditions. The principle and the significance of the required travel or force are explained by OMRON in its direct opening overview.
Read the NO and NC designations relative to the reference state shown in the diagram. The number of contacts does not say whether the paths are electrically separated, what their timing is or how they should be evaluated. A current rating must be linked to the voltage and utilisation category; it does not guarantee universal switching of motors. For a small control signal, on the other hand, check the minimum load conditions, not just the maximum current.
The travel to switching, the further permitted movement after switching and the difference between the switching and release positions describe different parts of the operating cycle. Repeatability, by contrast, expresses the scatter of the achieved switching position on repetition; it is neither the total travel nor the stopping accuracy of the whole machine. This meaning is defined by the OMRON terminology overview.
The switch is not meant to replace a fixed end stop of the drive. The mechanics must allow it to be actuated correctly even with tolerances, inertia and wear. After the switching point is reached, you need a controlled reserve, but you must not exceed the permitted operating range. The drawing or switching diagram of the specific model is more important for this step than a general description of the series.
Consider ordinary position signalling of a carriage at a speed of 0.20 m/s. The model delay between the input change and the start of braking is 0.05 s, so the carriage travels 0.20 × 0.05 = 0.010 m during this time, i.e. 10 mm. With subsequent constant deceleration of 1 m/s², the further distance is v² / (2a) = 20 mm. The total model stopping distance is 30 mm.
The figures are not parameters of any listed switch, nor a calculation of a safe distance. They only show why the stopping position cannot be derived from the moment of switching alone. A real design involves further tolerances, variable load, control response and verified braking. The actuator overtravel is calculated from the specific approach geometry, not by simply taking over the carriage travel.
Check the strength of the bracket, the head position, the approach from both required directions, cable strain relief and sealing of the connection. The degree of protection applies under the manufacturer's conditions; one protected part does not prove the protection of the whole installation. After adjustment, test the slowest and fastest working movement and the return to rest.
Record the switching and release positions, the approach direction used and the test speed in the report. Without these conditions, two seemingly different measurements may only describe a different operating cycle, not a faulty switch.
No. A normally closed contact is only one property of the component. The required safety must be demonstrated by the design and verification of the entire function.
Only within an assembly supported by the manufacturer and after the function has been verified again. A change of geometry may shift the switching point, the actuation direction and the available travel reserve.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.