B102K20SH, EMAS, double control push button, yellow, 1 NO + 1 NC, 500 V DC, IP50
B102K20SH EMAS – double control push button, yellow, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS double push button switches with two buttons in one body, typically for start and stop. Choose by contacts, colours and illumination.
B102K20SH EMAS – double control push button, yellow, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B101K20HH-OK EMAS – double control push button, black, 2 NO, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B102K20KY-10 EMAS – double control push button, red, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B152K20KY EMAS – double control push button, red, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B152K20HB EMAS – double control push button, white, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B1B2K20KY EMAS – double control push button, red, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B1B2K20HB EMAS – double control push button, white, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B151K20HH-OK EMAS – double control push button, black, 2 NO, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
B1B1K20HH-OK EMAS – double control push button, black, 2 NO, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
CP102K20HB EMAS – double control push button, white, 1 NO + 1 NC, 500 V DC, IP65. Technical parameters, application, mounting and selection of the right variant.
CP102K20KY EMAS – double control push button, red, 1 NO + 1 NC, 500 V DC, IP65. Technical parameters, application, mounting and selection of the right variant.
CP102K21HB EMAS – double control push button, white, 1 NO + 1 NC, 500 V DC, IP65. Technical parameters, application, mounting and selection of the right variant.
CP102K21KY EMAS – double control push button, red, 1 NO + 1 NC, 500 V DC, IP65. Technical parameters, application, mounting and selection of the right variant.
B102K20SH-C EMAS – double control push button, yellow, 1 NO + 1 NC, 500 V DC, IP50. Technical parameters, application, mounting and selection of the right variant.
Prices include the recycling fee.
A double push button switch concentrates two related commands in one place on the panel. The benefit is a clear link between the actuating surfaces, for example for normal start and stop of a process or for selecting two directions. However, the two-colour front is not the only deciding factor. Check which actuator operates which contact, what the rest state means and how the control evaluates simultaneous actuation of both surfaces.
The range includes, for example, EMAS B101K20HH-OK with two normally open contacts, B102K20KY-10 with a combination of a normally open and a normally closed contact, and versions of the CP series. Different contacts may require different command processing, even if the front is of a similar size. Therefore, select a replacement according to the complete designation and function of the assembly, not according to the colour arrangement in the photo.
According to the manufacturer, the specific CP102K20KY is a red-green flat double push button for mounting size 22 mm with 1NO + 1NC. For the contact, it states 4 A at 230 V AC in category AC-15. See EMAS CP102K20KY technical data. The current rating does not describe a universal ability to control a motor directly, nor the parameters of any added light.
Two actuators by themselves do not prove mechanical interlocking, priority stop or two-hand safety control. For each pair, therefore, specify the permitted combinations. For direction commands, it may be desirable that simultaneous actuation triggers neither direction. For normal start and stop, stop may take priority. These requirements must be ensured by the specific control design; they cannot be attributed to the whole range based on appearance.
Likewise, an NC contact does not by itself represent a diagnostic safety channel. In the operating logic, activation can be distinguished from the closed rest state, but fault detection requires an assessment of the wiring and evaluation. If you require separate actuators, compare Non-illuminated push buttons. Maintaining a mechanical selection, on the other hand, is handled by Latching push button switches.
Consider a pair of requests A and B for scrolling through a service screen. After processing the electrical inputs, each request has a value of zero or one. In total there are 2 × 2 = 4 combinations: no request, only A, only B and both at the same time. The model assigns waiting, step forward and step back to the first three states; the fourth state is suppressed until both surfaces are released.
This is the author's example of a common user interface, not a safety function or a terminal diagram. If one physical contact is NC, the program must first correctly convert its rest level to the meaning “request not active”. Simply renaming the input to STOP or BACK does not change the electrical polarity of the signal.
Leave space on the panel for both labels and for actuation without unintentionally touching the other surface. Check the orientation of the whole element, the fastening of the contact blocks and the agreement of the diagram with the wire markings. If the assembly is illuminated, record the light supply and the meaning of the illumination separately; the light is not a third mechanical contact.
No. In this range, for example, 2NO and 1NO + 1NC. differ. Assess each variant separately.
No. The number of actuating surfaces does not prove the required arrangement, time evaluation, resistance to defeat or other properties of a safety function.
If you cannot find the item you need in the e-shop, contact us with your enquiry and the complete specification of the required version.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.