91WA1-BA1B00ACA5AA, Endress+Hauser, Proline Prosonic Flow ultrasonic flowmeter
91WA1-BA1B00ACA5AA Endress+Hauser – ultrasonic flowmeter. Industrial product for process measurement and automation.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
ifm and Endress+Hauser flow sensors for liquids and gases – calorimetric flow monitors, flow meters and Prosonic Flow ultrasonic flow meters. Choose by medium, by whether you need to monitor flow or measure volume, and by output.
91WA1-BA1B00ACA5AA Endress+Hauser – ultrasonic flowmeter. Industrial product for process measurement and automation.
electrical design DC PNP, supply voltage 19 – 30 VDC, output function analogue 4 - 20mA, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, protection IP67, pressure rating…
electrical design DC PNP, supply voltage 19 – 30 VDC, output function NO/NC, programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, measuring range for gases 200…
electrical design DC PNP, supply voltage 19 – 30 VDC, 2 output functions: 1x NO/NC programmable 1x temperature monitoring, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s…
electrical design DC PNP, supply voltage 19 – 30 VDC, output function 2x NO/NC programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s measuring range for gases 200…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...25 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...50 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…
electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...100 l/min, medium temperature -10°C .. +70°C, protection IP67 - pressure rating 16bar - process…
SM6000, flow sensor; voltage: 19-30VDC; output: PNP/NPN; SMR12GGXFRKG/US-100, IFM
electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…
electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…
Prices include the recycling fee.
A flow meter should answer the question of how much medium flows through a pipe in a certain time. A flow monitor may address a narrower task: whether cooling or lubrication is flowing at all. Confusing these functions means expecting litres per minute from a device that provides only a switching state or a value related to local velocity.
The range consists of IFM SI5000, SI5002, SI5004 and SI5007, calorimetric monitors, SM6000/6050, SM7000/7050 and SM8000/8050 magnetic-inductive models and Prosonic Flow 91W. ultrasonic devices. The same initial designation is no guarantee of the same range, nominal diameter, display or output type.
Specific IFM items can also be compared in the subcategory IFM flow sensors. Before ordering, distinguish between limit-state monitoring and quantitative measurement according to the function of the specific model.
IFM SI5000 uses the calorimetric principle: the flowing medium removes heat from a heated point. Its switching function is suitable for flow monitoring. The response is affected by the properties of the liquid or gas and the position of the tip; settings for one medium cannot be transferred to another without verification.
Product sheet SM6000 states magnetic-inductive measurement in the range 0.1–25 l/min and a conductivity requirement of at least 20 µS/cm. The basis is the voltage induced by the movement of a conductive liquid in a magnetic field. These are the conditions of this model, not the general suitability of the whole series for oils, gases or water of any purity.
Prosonic Flow 91W works ultrasonically with sensors attached to the outside of the pipe. The difference in transit time of sound downstream and upstream makes it possible to evaluate the movement of the liquid. The selection of the assembly must respect the dimensions and material of the pipe, acoustic coupling and the liquid; the clamp-on designation does not mean usability on every pipe.
Velocity is given, for example, in m/s, volumetric flow in l/min or m³/h. The relationship Q = v × A uses the mean velocity over the entire filled cross-section. Velocity measured locally at the wall or at the probe tip may not correspond to this mean value. The flow profile is changed by bends, valves, reducers and insufficiently filled pipes. Conversion from velocity to litres therefore cannot be based solely on the nominal pipe designation.
Consider a circular pipe with an actual inner diameter of 20 mm, a full cross-section and a known mean velocity of 0.8 m/s. Area A = π × 0.020²/4 ≈ 0,000314 m². The volumetric flow is approximately 0,000251 m³/s, i.e. 15.1 l/min. If the actual diameter were 18 mm, at the same mean velocity it would be about 12.2 l/min. This is a model of geometric sensitivity, not a guide to converting the SI5000 switching signal into an exact flow rate.
To totalise consumption, you need a continuous value or suitably set pulses and the correct time base. To detect insufficient cooling, hysteresis, response and behaviour at standstill are important. SM6050 is described in the range as a version without display with a 4–20 mA output; the operation and function combinations of another SM model cannot be automatically transferred to it.
In consumption records, distinguish between instantaneous flow and cumulative volume. Verify the behaviour of the counter during a power failure and the reset procedure according to the specific device. Merely displaying the l/min value does not confirm that the total consumption is stored or available to the higher-level system.
Before mounting, check the permissible pressure, temperature, seals and materials in contact with the medium. Design the inlet and outlet sections according to the specific manual, not by a universal multiple of the diameter. The measuring point must not systematically trap air. To check relationships in the cooling circuit, the following may also be useful: Temperature sensors.
Check for bubbles, pulsations, the position of the control valve and flow conditions. Electronic smoothing can calm the trend, but at the same time it extends the response and does not remove the cause of the measuring error.
No. It can also be an impermissible medium, air entrainment, a supply or transmission fault. In the evaluation, distinguish between device diagnostics and process zero. The basic rules for connecting the measuring chain are summarised in the category Process Sensors.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.