Flow Sensors

ifm and Endress+Hauser flow sensors for liquids and gases – calorimetric flow monitors, flow meters and Prosonic Flow ultrasonic flow meters. Choose by medium, by whether you need to monitor flow or measure volume, and by output.

Subcategories

Filters
Found 11 products
IN STOCK

91WA1-BA1B00ACA5AA, Endress+Hauser, Proline Prosonic Flow ultrasonic flowmeter

Cat. no.: 91WA1-BA1B00ACA5AA

91WA1-BA1B00ACA5AA Endress+Hauser – ultrasonic flowmeter. Industrial product for process measurement and automation.

In stock 5 or more pcs
3 021,20 €
excl. VAT · 3 655,66 € incl. VAT
OUR TIP

Flow sensor SI5004 IFM, SID10ADB100G/US-100

Cat. no.: SI5004

electrical design DC PNP, supply voltage 19 – 30 VDC, output function analogue 4 - 20mA, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, protection IP67, pressure rating…

On request
308,60 €
excl. VAT · 373,40 € incl. VAT
OUR TIP

Flow sensor SI5000 IFM, SID10ABBFPKG/US-100

Cat. no.: SI5000

electrical design DC PNP, supply voltage 19 – 30 VDC, output function NO/NC, programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s, measuring range for gases 200…

On request
310,16 €
excl. VAT · 375,29 € incl. VAT
OUR TIP

Flow sensor SI5007 IFM, SID10ADBFPKG/US-100

Cat. no.: SI5007

electrical design DC PNP, supply voltage 19 – 30 VDC, 2 output functions: 1x NO/NC programmable 1x temperature monitoring, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s…

On request
321,61 €
excl. VAT · 389,15 € incl. VAT
OUR TIP

Flow sensor SI5002 IFM, SID10ADBFPKG/US-100

Cat. no.: SI5002

electrical design DC PNP, supply voltage 19 – 30 VDC, output function 2x NO/NC programmable, medium temperature -25°C +80°C, measuring range for liquids 3 ..300 cm/s measuring range for gases 200…

On request
326,52 €
excl. VAT · 395,09 € incl. VAT
OUR TIP

Flow sensor SM6050 IFM, SMR12GGX1OKG/US-100

Cat. no.: SM6050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...25 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…

On request
436,19 €
excl. VAT · 527,78 € incl. VAT
OUR TIP

Flow sensor SM7050 IFM, SMR34GGX1OKG/US100

Cat. no.: SM7050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...50 l/min, medium temperature -10°C .. +70°C, protection IP67, pressure rating 16bar, process…

On request
524,76 €
excl. VAT · 634,97 € incl. VAT
OUR TIP

Flow sensor SM8050 IFM, SMR11GGX1OKG/US100

Cat. no.: SM8050

electrical design DC, supply voltage 19 – 30 VDC, output signal analogue 4 – 20mA, measuring range 0...100 l/min, medium temperature -10°C .. +70°C, protection IP67 - pressure rating 16bar - process…

On request
628,00 €
excl. VAT · 759,88 € incl. VAT
OUR TIP

SM6000, flow sensor, SMR12GGXFRKG/US-100, IFM

Cat. no.: SM6000

SM6000, flow sensor; voltage: 19-30VDC; output: PNP/NPN; SMR12GGXFRKG/US-100, IFM

On request
670,92 €
excl. VAT · 811,81 € incl. VAT
OUR TIP

Flow sensor SM7000 IFM, SMR34GGXFRKG/US-100

Cat. no.: SM7000

electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…

On request
672,25 €
excl. VAT · 813,42 € incl. VAT
OUR TIP

Flow sensor SM8000 IFM, SMR11GGXFRKG/US-100

Cat. no.: SM8000

electrical design DC PNP/NPN, supply voltage 19 – 30 VDC, 2 independent output signals: OUT1 = flow monitoring (binary), quantity counter (pulses), OUT2 = flow or temperature monitoring (binary or…

On request
775,60 €
excl. VAT · 938,48 € incl. VAT

Prices include the recycling fee.

Flow sensors

A flow meter should answer the question of how much medium flows through a pipe in a certain time. A flow monitor may address a narrower task: whether cooling or lubrication is flowing at all. Confusing these functions means expecting litres per minute from a device that provides only a switching state or a value related to local velocity.

The range consists of IFM SI5000, SI5002, SI5004 and SI5007, calorimetric monitors, SM6000/6050, SM7000/7050 and SM8000/8050 magnetic-inductive models and Prosonic Flow 91W. ultrasonic devices. The same initial designation is no guarantee of the same range, nominal diameter, display or output type.

Specific IFM items can also be compared in the subcategory IFM flow sensors. Before ordering, distinguish between limit-state monitoring and quantitative measurement according to the function of the specific model.

Three principles, three important conditions

IFM SI5000 uses the calorimetric principle: the flowing medium removes heat from a heated point. Its switching function is suitable for flow monitoring. The response is affected by the properties of the liquid or gas and the position of the tip; settings for one medium cannot be transferred to another without verification.

Product sheet SM6000 states magnetic-inductive measurement in the range 0.1–25 l/min and a conductivity requirement of at least 20 µS/cm. The basis is the voltage induced by the movement of a conductive liquid in a magnetic field. These are the conditions of this model, not the general suitability of the whole series for oils, gases or water of any purity.

Prosonic Flow 91W works ultrasonically with sensors attached to the outside of the pipe. The difference in transit time of sound downstream and upstream makes it possible to evaluate the movement of the liquid. The selection of the assembly must respect the dimensions and material of the pipe, acoustic coupling and the liquid; the clamp-on designation does not mean usability on every pipe.

Flow velocity is not volumetric flow

Velocity is given, for example, in m/s, volumetric flow in l/min or m³/h. The relationship Q = v × A uses the mean velocity over the entire filled cross-section. Velocity measured locally at the wall or at the probe tip may not correspond to this mean value. The flow profile is changed by bends, valves, reducers and insufficiently filled pipes. Conversion from velocity to litres therefore cannot be based solely on the nominal pipe designation.

Model calculation: pipe geometry

Consider a circular pipe with an actual inner diameter of 20 mm, a full cross-section and a known mean velocity of 0.8 m/s. Area A = π × 0.020²/4 ≈ 0,000314 m². The volumetric flow is approximately 0,000251 m³/s, i.e. 15.1 l/min. If the actual diameter were 18 mm, at the same mean velocity it would be about 12.2 l/min. This is a model of geometric sensitivity, not a guide to converting the SI5000 switching signal into an exact flow rate.

Output and mounting for real operation

To totalise consumption, you need a continuous value or suitably set pulses and the correct time base. To detect insufficient cooling, hysteresis, response and behaviour at standstill are important. SM6050 is described in the range as a version without display with a 4–20 mA output; the operation and function combinations of another SM model cannot be automatically transferred to it.

In consumption records, distinguish between instantaneous flow and cumulative volume. Verify the behaviour of the counter during a power failure and the reset procedure according to the specific device. Merely displaying the l/min value does not confirm that the total consumption is stored or available to the higher-level system.

Before mounting, check the permissible pressure, temperature, seals and materials in contact with the medium. Design the inlet and outlet sections according to the specific manual, not by a universal multiple of the diameter. The measuring point must not systematically trap air. To check relationships in the cooling circuit, the following may also be useful: Temperature sensors.

FAQ

Why does the value fluctuate when the pump runs continuously?

Check for bubbles, pulsations, the position of the control valve and flow conditions. Electronic smoothing can calm the trend, but at the same time it extends the response and does not remove the cause of the measuring error.

Does a zero signal always mean zero flow?

No. It can also be an impermissible medium, air entrainment, a supply or transmission fault. In the evaluation, distinguish between device diagnostics and process zero. The basic rules for connecting the measuring chain are summarised in the category Process Sensors.