Phone +420 774 723 123 Cart · 0 · empty

IFM Temperature Sensors

ifm temperature sensors with or without display, with switching, analogue or IO-Link output. Choose by range, probe length, process connection and output.

Filters
Found 0 products

Prices include the recycling fee.

IFM temperature sensors

Industrial temperature measurement must provide the correct value at the correct place and at an appropriate speed. For heating control, delay can be as important as the error of the steady reading. When choosing an IFM sensor, therefore, first describe the course of the process: what is heated, how fast the temperature changes and what information the control system or operators need.

Integrated and modular measurement

IFM, in its temperature sensor selection overview distinguishes between an integrated device and a modular combination of a probe with evaluation electronics. These are two different ways of building a measuring chain. With a modular solution, the compatibility of both parts is verified; the integrated version is ordered as a specific unit. The availability of individual order codes must be verified separately.

The manufacturer's description of IFM measuring technologies explains that a resistance element changes resistance according to temperature and that the design of the measuring tip affects heat transfer. It is therefore not just a matter of choosing a range in the program. The same media temperature can, during a rapid change, lead to different instantaneous readings from two differently installed probes.

What to determine before selection

Separate the temperature of the medium from the ambient temperature of the electronics. Add the material and flow of the medium, pressure, mounting location, space for the cable and the possibility of service removal. For the electrical part, determine whether the input expects resistance directly, an analogue signal or communication. The number of connector contacts alone does not answer this question; the diagram and function of the individual pins are decisive.

For the offer, also prepare the required error and the time within which the measurement should capture a change. Do not describe both with the single word "accurate". Steady-state deviation, display resolution and dynamic response characterise different properties. The acceptance test should assess each important property appropriately.

Author's example: response speed

Consider an ideal first-order sensor with a model time constant of 4 seconds. The medium changes temperature stepwise from 20 to 60 °C. According to the relationship T(t) = 60 − 40 × exp(−t/4), the sensor will show approximately 45.3 °C after 4 seconds and 58.0 °C after 12 seconds. The time constant therefore does not mean the time to fully reach the final temperature.

This is the author's model without reference to a specific IFM product. The actual course is affected by mounting and the process; it cannot automatically be described by a single constant. The example explains why, during acceptance, it makes no sense to compare two probes without a simultaneous record of the time and conditions of the change.

Mounting and troubleshooting

Check the actual position of the measuring part relative to the medium and the required insertion depth according to the specific manual. If the reading responds slowly, check the position, thermal contact and set filtering one by one. If it is offset even after stabilisation, compare the input configuration and the reference instrument. Do not eliminate a fault whose cause is not yet known by changing the offset.

After mounting, record the initial settings, units and signal assignment in the control system. Also verify disconnection and restoration of power. For other designs, use Temperature sensors; for cooling circuits, the check is supplemented by IFM flow sensors.

FAQ

Does fine display resolution prove a small error?

No. Resolution determines the size of the displayed step, not in itself the measurement deviation or its uncertainty.

Is the sensor speed the same in every installation?

Compare the manufacturer's test conditions with your own installation. Verify the response at the measuring point.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.