Phone +420 774 723 123 Cart · 0 · empty

Temperature Sensors

Temperature sensors – TECHNOLINE, Enda and ifm Pt100 and Pt1000 resistance probes and thermocouples. Choose by sensor type, wiring (two-, three- or four-wire), probe length and diameter and mechanical design.

Subcategories

Filters
Found 6 products
IN STOCK

PTE100-40-06-PS60-G1/4, TECHNOLINE, PT100 sensor

Cat. no.: PTE100-40-06-PS60-G1/4

PTE100-40-06-PS60-G1/4, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.

In stock 5 or more pcs
12,66 €
excl. VAT · 15,32 € incl. VAT
IN STOCK

PTE100-40-4.6-WP, TECHNOLINE, PT100 sensor

Cat. no.: PTE100-40-4.6-WP

PTE100-40-4.6-WP, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.

In stock 3 ks
13,48 €
excl. VAT · 16,31 € incl. VAT
IN STOCK

Ring-lug thermocouple 6mm, 3m, ETBSKP06-5.0C, Enda

Cat. no.: ETBSKP06-5.0C

Ring-lug thermocouple 6mm, 3m, ETBSKP06-5.0C, Enda

In stock 5 or more pcs
23,66 €
excl. VAT · 28,63 € incl. VAT
IN STOCK

Pt100 element, EP0812-5.0C PT100, 3m, Enda

Cat. no.: EP0812-5.0C PT100

Pt100 element, EP0812-5.0C PT100, 3m, Enda

In stock 2 ks
51,58 €
excl. VAT · 62,41 € incl. VAT

PTE100-30-4.6-WP, TECHNOLINE, PT100 sensor

Cat. no.: PTE100-30-4.6-WP

PTE100-30-4.6-WP, TECHNOLINE, PT100 sensor. PT100 resistance sensor for precise industrial temperature measurement. Parameters and availability at Technoline.cz.

On request
13,07 €
excl. VAT · 15,82 € incl. VAT

Pt100 element, EP0630-5.0C PT100, 3m, Enda

Cat. no.: EP0630-5.0C PT100

Pt100 element, EP0630-5.0C PT100, 3m, Enda

On request
51,58 €
excl. VAT · 62,41 € incl. VAT

Prices include the recycling fee.

Temperature sensors

A temperature sensor must match the measuring input and the point whose temperature you want to know. A probe inserted in a thermowell, a sensor pressed against a surface and a ring lug under a screw monitor different thermal conditions. The range in the catalogue is therefore not the only criterion: the result is affected by insertion depth, contact pressure, heat dissipation to the surroundings and the rate of change.

The range includes TECHNOLINE Pt100 probes PTE100-40-06-PS60-G1/4, PTE100-30-4.6-WP and PTE100-40-4.6-WP, ENDA resistance probes EP0630 and EP0812 and the ring-lug thermocouple ETBSKP06-5.0C. The choice between them involves the electrical principle, mechanical fixing and the suitability of the specific design for the environment.

Selection by manufacturer can be found in the subcategories Enda temperature sensors, TECHNOLINE temperature sensors and IFM temperature sensors. The existence of a subcategory alone does not prove the current availability of a specific version.

Pt100 is not a thermocouple

Pt100 is a resistance thermometer with a nominal resistance of 100 Ω at 0 °C. The evaluation electronics measure the change in resistance and convert it to temperature. A thermocouple, by contrast, generates a small thermoelectric voltage; its evaluation depends on the type of metal pair and the temperature of the reference junction. A thermocouple input needs the appropriate characteristic and cold junction compensation. Simply reconnecting two wires does not turn one principle into the other.

The manufacturer ENDA for EP0630 states Pt100 with a diameter of 6 mm, an insertion length of 30 mm and connection M12×1.75. These dimensions describe the specific version; they do not automatically apply to EP0812 or to PTE100. probes

Two, three or four wires

With a two-wire Pt100, the resistance of both leads is added to the measured resistance. Three-wire connection allows compensation with corresponding, mutually identical lead resistances. Four-wire connection separates the current leads from the voltage sensing. The differences are explained by the WIKA technical guide to Pt100 wiring. The number of wires must be supported by both the probe and the input; it cannot be determined just from the name Pt100.

To extend the lead, verify the terminal diagram, shielding and connection method according to the electronics used. The third wire does not serve as a protective conductor. For a thermocouple, also check the correct extension or compensating cable and polarity. A random copper extension can create additional temperature-dependent junctions that do not manifest equally in all operating states.

Model calculation: lead error

Consider a two-wire Pt100 and a resistance of each lead of 0.5 Ω. The added resistance is 1 Ω. For a simplified local model with a resistance change of approximately 0.385 Ω/°C, the offset is 1/0.385 ≈ 2.6 °C upwards. This is not an exact characteristic for the whole range nor a declared error of the probe offered. The model shows why a long lead can negate the benefit of a more accurate sensing element.

Mechanical design and actual response

A surface ring lug needs stable thermal contact with the measured point; it does not automatically follow the temperature of the liquid inside a distant pipe. With an inserted probe, the sensitive area must reach into a representative part of the medium. A thermowell allows isolation from the process but adds thermal resistance and inertia. Shorter insertion can increase the influence of ambient temperature and the threaded neck.

Also check the chemical resistance of the sheath, seals and cable. Suitability for liquid, pressure or washing cannot be derived solely from the metallic appearance of the probe. If the measurement relates to cooling, combine temperature information with an appropriate check in the category Flow sensors. A higher temperature may be the result of lower flow, not a fault of the temperature sensor.

When comparing two thermometers, wait for thermal stabilisation and ensure similar contact conditions. A device held on the pipe surface and a probe in the medium flow can correctly show different temperatures. A calibration correction should not be used to mask incorrect placement or insufficient insertion.

FAQ

Why does the new sensor respond more slowly?

Compare the diameter, thermowell, insertion depth, contact pressure and software filter. The same electrical range does not mean the same dynamics. For control, the response of the entire measuring point is important, not just the element itself.

Can Pt100 be connected directly to a 4–20 mA input?

The resistance element alone cannot. It needs a resistance input or a suitable transmitter; the presence of a transmitter must be documented for the specific assembly. The other parts of the measuring chain and their links are summarised in the overview Process Sensors.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.