FSR 650W, ELSTEIN, ceramic infrared emitter 650W, 245×60mm, without thermocouple
FSR 650W, ELSTEIN, ceramic infrared emitter 650W, 245×60mm, without thermocouple. FSR is a ceramic panel infrared emitter for process heating.
Rate 24,39 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Elstein ceramic infrared heaters for industrial heating – plastics forming, drying, curing and space heating. The heaters transfer heat directly to the product. Choose by size, power, supply voltage and whether you need a built-in thermocouple for control.
FSR 650W, ELSTEIN, ceramic infrared emitter 650W, 245×60mm, without thermocouple. FSR is a ceramic panel infrared emitter for process heating.
T-FSR/4 60W, ELSTEIN, FSR ceramic infrared emitter, 60W, 60×60mm, thermocouple K. The FSR ceramic infrared emitter in variant 60W and size 60×60mm contains a type K thermocouple for measuring the…
T-FSR/4 100W, ELSTEIN, ceramic infrared emitter 100W, 60×60mm, thermocouple K. FSR is a ceramic panel infrared emitter for process heating.
T-FSR/2 125W, ELSTEIN, ceramic infrared emitter 125W, 122×60mm, thermocouple K. FSR is a ceramic panel infrared emitter for process heating.
T-HTS/4 60W ELSTEIN – ceramic infrared emitter with thermocouple , 60 x 60mm, order no. 60600, 60 W, type K (NiCr-Ni). Key data: ELSTEIN HTS, 230 V, 860 °C. Exact technical data for selecting the…
T-FSR/4 200W, ELSTEIN: FSR ceramic infrared emitter with K thermocouple for temperature sensing, power input 200W, size 60×60mm, supply 230VAC.
T-FSR 150W, ELSTEIN, ceramic infrared emitter 150W, 245×60mm, 230VAC, thermocouple K. ELSTEIN T-FSR 150W ceramic infrared emitter with a power of 150W and an area of 245×60mm for process heating.
T-FSR/2 200W, ELSTEIN: FSR ceramic infrared emitter with K thermocouple for temperature sensing, power input 200W, size 122×60mm, supply 230VAC.
T-FSR/4 250W, ELSTEIN: FSR ceramic infrared emitter with K thermocouple for temperature sensing, power input 250W, size 60×60mm, supply 230VAC.
T-HTS/2 125W, ELSTEIN, ceramic infrared emitter 125W, 122×60mm, thermocouple K. HTS is a ceramic panel infrared emitter for process heating.
T-HTS/4 100W, ELSTEIN: HTS ceramic infrared emitter with K thermocouple for temperature sensing, power input 100W, size 60×60mm, supply 230VAC.
T-FSR 250W, ELSTEIN, ceramic infrared emitter 250W, 245×60mm, thermocouple K. FSR is a ceramic panel infrared emitter for process heating.
T-FSR/2 325W, ELSTEIN, FSR ceramic infrared emitter, 325W, 122×60mm, thermocouple K. The FSR ceramic infrared emitter in variant 325W and size 122×60mm contains a type K thermocouple for measuring…
FSR 1000W, ELSTEIN: FSR ceramic infrared heating element with a power input of 1000W at 230VAC, ceramic body size 245×60mm.
HTS 600W, ELSTEIN, ceramic infrared emitter 600W, 122×122mm, without thermocouple. HTS is a ceramic panel infrared emitter for process heating.
HTS/1 600W, ELSTEIN: HTS ceramic infrared heating element with a power input of 600W at 230VAC, ceramic body size 245×60mm.
T-HTS/2 200W ELSTEIN – ceramic infrared emitter with thermocouple , 122 x 60mm, order no. 60301, 200 W, type K (NiCr-Ni). Key data: ELSTEIN HTS, 230 V, 860 °C. Exact technical data for selecting the…
T-HTS/4 150W, ELSTEIN: HTS ceramic infrared emitter with K thermocouple for temperature sensing, power input 150W, size 60×60mm, supply 230VAC.
T-HTS/4 200W, ELSTEIN, ceramic infrared emitter 200W, 60×60mm, thermocouple K. HTS is a ceramic panel infrared emitter for process heating.
T-HTS/4 250W, ELSTEIN, HTS ceramic infrared emitter, 250W, 60×60mm, thermocouple K. The HTS ceramic infrared emitter in variant 250W and size 60×60mm contains a type K thermocouple for measuring the…
T-HTS 250W ELSTEIN – ceramic infrared emitter with thermocouple , 122 x 122mm, order no. 60000, 250 W, type K (NiCr-Ni). Key data: ELSTEIN HTS, 230 V, 860 °C. Exact technical data for selecting the…
T-HTS/1 250W, ELSTEIN: HTS ceramic infrared emitter with K thermocouple for temperature sensing, power input 250W, size 245×60mm, supply 230VAC.
T-HTS/2 300W, ELSTEIN, HTS ceramic infrared emitter, 300W, 122×60mm, thermocouple K. The HTS ceramic infrared emitter in variant 300W and size 122×60mm contains a type K thermocouple for measuring…
T-FSR 400W, ELSTEIN, FSR ceramic infrared emitter, 400W, 245×60mm, thermocouple K. The FSR ceramic infrared emitter in variant 400W and size 245×60mm contains a type K thermocouple for measuring the…
T-FSR/2 500W, ELSTEIN, ceramic infrared emitter 500W, 122×60mm, thermocouple K. FSR is a ceramic panel infrared emitter for process heating.
Prices include the recycling fee.
Choose a ceramic infrared emitter according to the task the heating field is to perform. Uniform preheating of a board is assessed differently from short exposure of a moving web. Before buying, define the permissible temperature non-uniformity, cycle time and the method of inspecting the finished product. The sum of watts alone does not describe these requirements.
Infrared radiation transfers energy without direct contact of the heating element with the product. According to the ELSTEIN explanation of emission and absorption the incident radiation is partly absorbed, reflected or transmitted depending on the material and wavelength. The absorbed part is decisive for heating. The electrical power input is therefore not the same as the power actually received by the product.
In the brief, separate three values: the emitter temperature, the product surface temperature and the required temperature inside the product. During testing, determine which value decides the result of the process. If acceptance evaluates the whole cross-section, it is not enough to record only the hottest spot on the surface. The chosen measurement must correspond to this objective.
For a specific version, continue to the categories Energy-saving ceramic infrared emitters Elstein - HTS and Economical ceramic infrared emitters Elstein - FSR. The branch High-speed infrared emitters currently contains no product items.
ELSTEIN design principles recommend verifying the required power and exposure time by testing the material. When designing the heating assembly, they require thermal expansion and protection against contact with hot parts to be taken into account.
For your own design, draw the outline of the product, the movement, shading by the fixture and the measuring points. Divide the acceptance report into centre, edges and corners. Define a separate permissible interval for each point. This makes it possible to distinguish an insufficient total energy input from unsuitable spatial distribution without reducing the selection to a single highest measured temperature. Also record the initial temperature of the part, its orientation and loading method. Restore these conditions when repeating the test. A change in the result will then not unnoticedly mix the influence of the machine setting with different sample preparation.
Consider a purely model part with a mass of 0.20 kg, a constant specific heat capacity of 1.5 kJ/(kg·K) and a required temperature increase of 80 K. The ideal energy is Q = m·c·ΔT = 24 kJ. If it is to be delivered in 30 seconds, the average power received by the part is 0.80 kW. The model neglects heat losses, evaporation and phase change; it does not determine the power input or a specific emitter.
If, purely for the sensitivity of the calculation, we choose a share of energy received by the part of 0.40, the required electrical input of the model will be 2.0 kW. This share is a fictitious input, not an ELSTEIN efficiency. In the project, it must be replaced by measurement. The example shows why the electrical and material balances are kept separate.
The ELSTEIN mounting instructions entrust installation to electrically and thermally qualified personnel. They require suitable equipment, protection against contact and a non-combustible support structure. Damaged emitters must not continue to be operated.
When looking for the cause of non-uniformity, always compare the same place on the product and the same moment of the cycle. Record changes to the fixture, recipe and input material. If the deviation repeats only in one position, prepare a test focused on that position. Leave electrical checks and interventions to a qualified worker after the equipment has been safely shut down.
No. Define acceptance conditions for the product and verify them separately. The emitter value may serve to control the source, but it does not replace checking the process result.
It is a starting point for a new test, not a confirmed production procedure. Compare the results on the actual material, including the edges, repeatability and quality after completion of the cycle.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.