Phone +420 774 723 123 Cart · 0 · empty

LANBAO magnetic sensors

Lanbao FT07 magnetic sensors for T-slot – reed and electronic PNP with PVC or PUR cable. Choose by wiring and cable length.

Filters
Found 6 products
−10 % OUR TIP IN STOCK

FT07DPO, LANBAO, magnetic sensor, 10-30VDC, PNP, NO, cable 2m

Cat. no.: FT07DPO

FT07DPO LANBAO – magnetic sensor, PNP, NO, T, cable 2m. Industrial product for automation, detection or measurement.

In stock 5 or more pcs
13,01 € 14,45 €
excl. VAT · 15,74 € incl. VAT
−10 % OUR TIP IN STOCK

TFT07DPO-50E1, LANBAO, magnetic sensor, 10-30VDC, PNP, NO, cable 0, 5m + connector M8/3

Cat. no.: TFT07DPO-50E1

TFT07DPO-50E1 LANBAO – magnetic sensor, M8, PNP, NO, T, cable 0.5m. Industrial product for automation, detection or measurement.

In stock 5 or more pcs
13,41 € 14,90 €
excl. VAT · 16,23 € incl. VAT
−10 % OUR TIP IN STOCK

FT07DLO-5M, LANBAO, FT07-DLO-5M, magnetic sensor, 10-30VDC, Reed contact, NO, cable 5m

Cat. no.: FT07DLO-5M

FT07DLO-5M LANBAO – magnetic sensor, NO, T, cable 5m. Industrial product for automation, detection or measurement.

In stock 5 or more pcs
13,41 € 14,90 €
excl. VAT · 16,23 € incl. VAT
−10 % OUR TIP IN STOCK

FT07-DLO, LANBAO, magnetic sensor, NO, cable 2 m PVC

Cat. no.: FT07-DLO

FT07-DLO – LANBAO magnetic proximity sensor. NO, cable 2 m PVC, IP67. In stock at Technoline – datasheet, technical support, invoice.

In stock 5 or more pcs
13,41 € 14,90 €
excl. VAT · 16,23 € incl. VAT
−10 % OUR TIP IN STOCK

FT07DPO-5M, LANBAO, magnetic sensor, 10-30VDC, PNP, NO, cable 5m

Cat. no.: FT07DPO-5M

FT07DPO-5M LANBAO – magnetic sensor, PNP, NO, T, cable 5m. Industrial product for automation, detection or measurement.

In stock 5 or more pcs
13,82 € 15,35 €
excl. VAT · 16,72 € incl. VAT
−10 % OUR TIP IN STOCK

FT07DPO-2MPUR, LANBAO, magnetic sensor, 10-30VDC, PNP, NO, cable 2m

Cat. no.: FT07DPO-2MPUR

FT07DPO-2MPUR LANBAO – magnetic sensor, PNP, NO, T, cable 2m. Industrial product for automation, detection or measurement.

In stock 5 or more pcs
14,63 € 16,25 €
excl. VAT · 17,70 € incl. VAT

Prices include the recycling fee.

LANBAO magnetic sensors

For the LANBAO FT07 series, choose the electrical variant and the cable design at the same time. The range includes T-slot sensors with a reed contact or PNP output. A similar body shape does not mean identical wiring. Before replacing, therefore, copy the complete order code including the suffixes indicating the cable.

Examples of versions in the range

Selection by cabling and machine input

  1. Start with the diagram of the existing wiring. Find out whether you are replacing a contact in a two-wire circuit or a sensor with separate supply and output.
  2. Measure the required length along the actual route, including a service reserve. Choose the five-metre variant according to the routing in the machine, not the straight-line distance to the terminal block.
  3. Record the cable installation method and environment. Do not use the PVC or PUR material alone as a substitute for verifying the permitted movement, bending and chemical resistance of the cable.
  4. Compare the installation drawing with the T-slot profile. Prepare space for fixing, the cable outlet and future replacement without unnecessary dismantling of surrounding parts.
  5. Test the selected type with the specific cylinder and control input. Record the wiring used and the set position.

Example found: reed FT07DLO

The official LANBAO page classifies FT07DLO among reed sensors and specifies a supply of 10–30 V DC, a maximum load of 50 mA and a contact rating of 1 W. When assessing the circuit, check all these limits at the same time. The values cannot be automatically transferred to FT07DPO or another cable version. Source: LANBAO FT07 Reed series.

If you have several cylinders with terminal blocks at different distances, create a separate cable specification for each location. Also list the cable route and the strain relief method. This separates the requirement for the electrical variant FT07 from the mere need for a longer line in the machine.

Common mistakes and FAQ

Can DLO and DPO be interchanged without checking the diagram?

No. The documented cards differ in the number of wires and the output description. First compare the connection and input requirements; the same NO designation alone is not enough.

Is PUR automatically suitable for a cable chain?

Have such a property confirmed for the complete order code. In the enquiry, state the stroke length, bending radius and frequency of movement. The jacket material is only one data point.

Does it make sense to keep the old cabling during replacement?

First determine the cause of the fault. Check the route, fixing and the point of stress so that the new sensor does not repeat the same problem. Choose any connecting parts according to the diagram.

Other designs can be found among magnetic sensors; the follow-on connection is handled by Sensor Cables and Connectors.

Cookies on this website