Solid-state relays (SSR)
Choose an SSR together with the load, control and thermal design. The range includes EMAS SSRP1DA012, SSRP1DA025 and SSRP1DA040, RELPOL relays RSR30, assemblies with PI6W-1P and heat sink SSS2X. The presence of a heat sink in the same category does not in itself confirm its suitability for every combination of current, temperature and mounting.
Deciding: AC or DC output
RELPOL data sheet RSR30 distinguishes a triac AC output and a MOSFET for DC. DC control can operate both; the input voltage does not determine the type of switched load.
The separate EMAS data sheet SSRP1DA025 states a load of 25 A in category AC51. Such a figure is not a universal motor or inductive load capacity. For your load, request the corresponding current waveform and cooling conditions; merely comparing steady-state amps is not enough.
Principle of zero-cross and random switching
OMRON describes zero-cross as switching on near the zero crossing of the AC load voltage. The random version switches on after the command without this wait; this is how RELPOL designates the AC variants in the data sheet mentioned. Relate the choice to the control mode. An SSR alone is not a temperature controller or automatically a phase-angle controller.
With a triac output, switching off depends on the current dropping to zero, as explained in OMRON technical guidance. Therefore do not regard the AC version as a universal replacement for a DC switch. When controlling heating, also verify the timing mode of the controller used.
Author's model example: heat balance
For a simplified model, consider a constant current of 8 A and a constant voltage drop across the conducting semiconductor of 1.2 V. The power loss is 8 × 1.2 = 9.6 W. With a model permissible temperature rise of 30 K, the maximum total thermal resistance of the path is 30/9.6 ≈ 3.13 K/W.
This is an author's brief, not the parameters of the SSR offered or a heat sink recommendation. The total path also includes the housing and the thermal joint, not just the heat sink. The calculation is steady-state and simplified; it does not describe current peaks or exact losses with an AC waveform. The actual design must be based on the characteristics of the specific component.
Mounting and heat dissipation
According to the OMRON guidance mentioned, the position, airflow and temperature inside the control cabinet matter. The permissible current is assessed for the given cooling.
In the project documentation, mark the simultaneously active circuits and adjacent heat sources. Attach the characteristic used or a request for additional data to each assumption. When the fitting changes, compare the documentation with the actual layout again.
Diagnostics: leakage and failure with the output on
In the off state, a leakage current may flow through the output. Faint glowing of a sensitive load therefore does not by itself prove full switch-on. OMRON also warns of short-circuit failure, i.e. fail-short: the SSR then cannot switch off the load. The design must provide independent disconnection and protection according to the specific risk.
For servicing, record the command, the behaviour of the load and the thermal conditions separately. Arrange professional safeguarding of the workplace according to the equipment documentation. For operational switching with mechanical contacts, also compare electromagnetic relays; the properties of the downstream protective combination require separate verification.
FAQ
Is every AC SSR of the zero-cross type?
No. The documentation of the specific variant is decisive; random switching also exists. You cannot tell the mode from the SSR designation alone.
Does a higher current rating guarantee operation without a heat sink?
No. Compare the conditions under which the manufacturer states the current with the actual installation and thermal design.