Phone +420 774 723 123 Cart · 0 · empty

SICK magnetic sensors

SICK magnetic sensors for piston position sensing (RZT, MZT, MZC), continuous MPS position measurement and RE safety door switches. Choose by purpose, slot and connection.

Filters
Found 13 products

RZT7-03ZRS-KP0, SICK, magnetic sensor, 1070847

Cat. no.: RZT7-03ZRS-KP0

RZT7-03ZRS-KP0 SICK – magnetic sensor, M8. Industrial product for automation, detection or measurement.

On request
30,70 €
excl. VAT · 37,15 € incl. VAT

MZT7-03VPS-KW0, SICK, magnetic sensor, magnetic field sensor, 1070838

Cat. no.: MZT7-03VPS-KW0

MZT7-03VPS-KW0 SICK – magnetic sensor, PNP, NO, cable 2m. Industrial product for automation, detection or measurement.

On request
36,02 €
excl. VAT · 43,59 € incl. VAT

MZC1-2V2PS-KP0, SICK, magnetic sensor, cylinder sensor, 1059735

Cat. no.: MZC1-2V2PS-KP0

MZC1-2V2PS-KP0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.

On request
37,25 €
excl. VAT · 45,07 € incl. VAT

RE13-SAC, SICK, magnetic sensor, 1059503, safety switch

Cat. no.: RE13-SAC

RE13-SAC SICK – magnetic sensor, M8, Reed contacts. Industrial product for automation, detection or measurement.

On request
45,85 €
excl. VAT · 55,48 € incl. VAT

RE27-SA68L, SICK, magnetic sensor, 1059509, safety switch

Cat. no.: RE27-SA68L

RE27-SA68L SICK – magnetic sensor, M12, Reed contacts. Industrial product for automation, detection or measurement.

On request
53,63 €
excl. VAT · 64,89 € incl. VAT

MZCG-1Z7PS-KR0, SICK, magnetic sensor, cylinder sensor, 1083703

Cat. no.: MZCG-1Z7PS-KR0

MZCG-1Z7PS-KR0 SICK – magnetic sensor, M8, PNP, Normally open contact, C. Industrial product for automation, detection or measurement.

On request
55,26 €
excl. VAT · 66,87 € incl. VAT

MPS-064TSTP0, SICK, magnetic sensor with analogue value, for T-slot

Cat. no.: MPS-064TSTP0

MPS-064TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.

On request
195,80 €
excl. VAT · 236,91 € incl. VAT

MPS-128TSTP0, SICK, SICK magnetic sensor with analogue value for T-slot

Cat. no.: MPS-128TSTP0

MPS-128TSTP0 SICK – magnetic sensor, M8, T. Industrial product for automation, detection or measurement.

On request
275,07 €
excl. VAT · 332,84 € incl. VAT

Prices include the recycling fee.

SICK magnetic sensors

The range combines three different tasks: switching the piston position, continuous measurement of its position and safety monitoring of protective doors. In addition to versions MPS-032, MPS-064, MPS-096 and MPS-128 it includes RZT7, MZT7, MZC1, MZCG as well as RE13-SAC and RE27-SA68L. Before comparing parameters, therefore, determine which task the ordered part is to perform.

Switching sensors: slot and output first

For a service replacement, separate mechanical from electrical compatibility. A similar designation or the same number of wires is not enough. Store the cylinder type, slot profile, expected input function and the exact code of the original sensor in the work sheet.

MPS: continuous position instead of a single point

The specific MPS-064TSTU0, 1045669 is designed for the T-slot and has a measuring range of 64 mm, while the housing measures 77 mm. The sheet specifies analogue 0–10 V or 4–20 mA; the corresponding connected output is activated.

Consider MPS where the control system needs a position value within a defined section. Before ordering, draw the required limits, the space for the housing and the connection route. Prepare a suitable control input and scaling for the specific variant; do not transfer the parameters of this example to all MPS lengths.

RE: a separate task for protective doors

RE1/RE2 are magnetic safety switches for movable guards in combination with a suitable safety evaluation unit. Selection requires a risk assessment and professional commissioning according to the SICK manual RE1/RE2. It is not a substitute for a standard cylinder sensor.

RE13-SAC, 1059503 contains a sensor with actuator, two switching contacts and a four-pole M8. RE27-SA68L, 1059509 additionally has a signalling contact and a 0.2 m cable with an eight-pole M12. Both sheets leave fault detection to the downstream safety logic. The PL achieved by the whole assembly therefore cannot be determined from the switch designation.

Selection and acceptance procedure

  1. Divide the requirement into a switching point, continuous measurement or guard monitoring. Record a separate requirement for each task.
  2. Compare the space, mounting, connector and wiring of the exact order number. For MPS add the measured section, for RE the corresponding actuator and the safety circuit documentation.
  3. Record the verified behaviour in the acceptance report. Do not confuse an ordinary function test of the position signal with validation of a safety function.

Common mistakes and FAQ

Does a piston sensor confirm completed clamping?

The position alone does not prove the clamping force or correct gripping of the part. Evaluate these requirements separately according to the machine.

Is it enough to choose a cable for RE by thread?

No. Compare the number and assignment of contacts with the specific sheet and the approved wiring. Buying a cable does not replace the assessment of the safety circuit.

Other brands can be compared among magnetic sensors. For connection, continue with Sensor Cables and Connectors; selection documents are covered by technical support.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.