Phone +420 774 723 123 Cart · 0 · empty

IFM Pressure Sensors

ifm pressure sensors and switches with display, switching, analogue or IO-Link output. Choose by pressure range, process connection and output.

Filters
Found 12 products

IFM pressure sensors PP7554 (PP-010-RBG14-QFRKG/BS/N) pressure sensor

Cat. no.: PP7554

This is a very high-quality pressure sensor made in Europe by IFM. High overload resistance even with sudden changes between vacuum and overpressure. Vacuum sensors monitor the vacuum to ensure a…

On request
219,28 €
excl. VAT · 265,33 € incl. VAT

IFM pressure sensors PP7552 (PP-010-RBG14-QFRKG/BS) pressure sensor

Cat. no.: PP7552

This is a very high-quality pressure sensor made in Europe by IFM. High overload resistance even with sudden changes between vacuum and overpressure. Vacuum sensors monitor the vacuum to ensure a…

On request
219,28 €
excl. VAT · 265,33 € incl. VAT

IFM pressure sensors PA3029 (PA-0-1-RBR14-A-ZVG/US) pressure sensor

Cat. no.: PA3029

This is a very high-quality pressure sensor made in Europe by IFM. High overload resistance even with sudden changes between vacuum and overpressure. Vacuum sensors monitor the vacuum to ensure a…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3022 (PA-100-SBR14-A-ZVG/US) pressure sensor

Cat. no.: PA3022

This is a very high-quality pressure sensor made in Europe by IFM. High overload resistance even with sudden changes between vacuum and overpressure. Vacuum sensors monitor the vacuum to ensure a…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3024 (PA-010-RBR14-A-ZVG/US) pressure sensor

Cat. no.: PA3024

This is a very high-quality pressure sensor made in Europe by IFM. Electronic pressure sensors are advantageous for their modular integration into the system and excellent overload resistance. The…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3027 (PA-001-RBR14-A-ZVG/US) pressure sensor

Cat. no.: PA3027

This is a very high-quality pressure sensor made in Europe by IFM. Pressure sensor, pressure sensors, pressure transducers, pressure transducer, pressure sensor, pressure sensors, vacuum sensors…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3026 (PA-2.5-RBR14-A-ZVG/US/V) pressure sensor

Cat. no.: PA3026

This is a very high-quality pressure sensor made in Europe by IFM. Pressure sensor, pressure sensors, pressure transducers, pressure transducer, pressure sensor, pressure sensors, vacuum sensors…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3020 (PA-400-SBR14-A-ZVG/US/V) pressure sensor

Cat. no.: PA3020

This is a very high-quality pressure sensor from IFM. Made in Europe. Electronic pressure sensors are advantageous for their modular integration into the system and excellent overload resistance. The…

On request
257,51 €
excl. VAT · 311,59 € incl. VAT

IFM pressure sensors PA3060 (PA-600-SBR14-A-ZVG/US/V) pressure sensor

Cat. no.: PA3060

This is a very high-quality pressure sensor from IFM. Made in Europe. Electronic pressure sensors are advantageous for their modular integration into the system and excellent overload resistance. The…

On request
265,66 €
excl. VAT · 321,44 € incl. VAT

Prices include the recycling fee.

IFM pressure sensors

IFM pressure sensors can pass a measured value or an evaluated switching state to the control system, depending on the specific version. When specifying, distinguish whether you need to monitor a trend, regulate pressure or confirm that a limit has been reached. A single binary signal does not contain the same information as continuous measurement, and the transmission method also affects diagnostics and commissioning.

Analogue transmitter and pressure switch

The public range includes, for example, PA3024, PA3029, PP7554 and PV7000. Product sheet PA3024 documents an analogue output of 4 to 20 mA and relative pressure measurement. By contrast, the manufacturer's overview of PV7000 states two switching outputs and IO-Link. The properties of one of these devices are therefore not a common specification for the whole category.

For each order code, check the measuring range, process thread and signals available on the connector separately. Also determine whether the limit is to be evaluated by the sensor itself or by the control program from the analogue value. Both procedures require a different configuration and are restored differently during service replacement.

Hysteresis creates two different points

The manufacturer's datasheet PV7000 distinguishes between the switch point SP and the reset point rP. In hysteresis mode, the state changes at different limits when pressure rises and falls. The setting of the points must correspond to the required logic and the permissible limits of the specific device. Inverting the NO/NC logic does not change the physical meaning of the measured pressure.

Author's example: sequence of states

For model switching, choose switching on at 6.0 bar and switching off when it drops to 5.5 bar. When rising from 5.0 to 5.8 bar, the output remains off. After reaching 6.1 bar it is on, and during a subsequent drop to 5.8 bar it remains on. It switches off only when the lower limit of 5.5 bar is reached.

The hysteresis difference is 0.5 bar. The value of 5.8 bar alone is therefore not enough to determine the state; the previous course also matters. The numbers are the author's and do not represent the recommended setting of PV7000. The example is not a design of a safety function nor proof that the chosen limits cover the requirements of a particular machine.

Filtering and checking the actual response

Add the required response to a short fluctuation and to a permanent change to the specification. During the test, simultaneously monitor the pressure, the sensor output and the resulting control action. Only then can you tell in which part the delay arises. A time filter or alarm delay can be useful, but its setting must be documented together with the reason for its use.

Prepare the mechanical connection according to the drawing of the selected model, the wetted materials and operating conditions. After safe depressurisation, verify the seal and mounting space. During acceptance, test rising and falling pressure, a disconnected signal and restart. The parameter backup should contain units, output functions and the actual limits used by the application.

For comparing analogue alternatives, use Simple pressure sensors. All related branches can be found in the overview Pressure sensors.

FAQ

Is IO-Link another analogue output?

No. It is a communication interface. Verify the available functions and their simultaneous use with switching according to the specific device.

Do two switching limits guarantee machine safety?

The number of outputs or set limits alone does not allow such a conclusion. A protective function requires an appropriate design and verification of the entire assembly.

Cookies on this website