Contactors and Motor Protection

Contactors and motor protection – NOARK, Siemens and EMAS contactors, auxiliary contacts and motor starters for protecting motors against overload and short circuit. Choose by motor power, coil voltage and auxiliary contacts.

Subcategories

Filters
Found 82 products
OUR TIP

Ex9CH20 11 220/230V 50/60Hz, NOARK, installation relay Ex9CH20, 20A, 1NO+1NC, coil 220–230VAC/50–60Hz

Cat. no.: Ex9CH20 11 220/230V 50/60Hz

Ex9CH20 11 220/230V 50/60Hz, NOARK: NOARK Ex9CH20 11 220/230V 50/60Hz is a modular installation relay with a rated operating current of 20A. It contains 1 make and 1 break contact and a coil for…

On request
15,79 €
excl. VAT · 19,11 € incl. VAT
OUR TIP

Ex9C18 11 3P 230V, Siemens, power contactor Ex9C, 3NO, AC-3 18A/400VAC, 7.5kW, coil 230VAC, 1NO+1NC

Cat. no.: Ex9C18 11 3P 230V

Ex9C18 11 3P 230V, Siemens: NOARK Ex9C18 11 3P 230V is a three-pole contactor with a 230VAC coil for motor circuits. For this exact variant, the manufacturer states a current of AC-3 18A at 400VAC, a…

On request
16,46 €
excl. VAT · 19,91 € incl. VAT

3RM1910-1DA, Siemens, three-phase busbar for 5 SIRIUS 3RM1 starters

Cat. no.: 3RM1910-1DA

3RM1910-1DA, Siemens: is a three-phase busbar for the common supply of 5 SIRIUS 3RM1. motor starters. It is an accessory of the supply system, not a standalone starter.

On request
19,60 €
excl. VAT · 23,72 € incl. VAT

3RT2023-1AL20, Siemens, SIRIUS power contactor S0, 3NO, AC-3 9A/400VAC, 4kW, coil 230VAC, 1NO+1NC

Cat. no.: 3RT2023-1AL20

3RT2023-1AL20, Siemens: is a three-pole SIRIUS power contactor for motor loads. In category AC-3 at 400VAC the rated current is 9A and the power 4kW. It is controlled by a 230VAC/50–60Hz coil; the…

On request
21,96 €
excl. VAT · 26,57 € incl. VAT
OUR TIP

Ex9C25 11 3P 230V, Siemens, power contactor Ex9C, 3NO, AC-3 25A/400VAC, 11kW, coil 230VAC, 1NO+1NC

Cat. no.: Ex9C25 11 3P 230V

Ex9C25 11 3P 230V, Siemens: NOARK Ex9C25 11 3P 230V is a three-pole contactor with a 230VAC coil for motor circuits. For this exact variant, the manufacturer states a current of AC-3 25A at 400VAC, a…

On request
21,99 €
excl. VAT · 26,61 € incl. VAT
OUR TIP

Ex9SN25B4A, NOARK, motor starter Ex9SN25B, thermal protection 2.5–4A, 3P, IP20

Cat. no.: Ex9SN25B4A

Ex9SN25B4A, NOARK Ex9SN25B: adjustable motor protection 2.5–4A, magnetic release 51A, 3 poles, IP20. For motors up to 1.5kW at 400VAC (AC-3).

On request
22,24 €
excl. VAT · 26,91 € incl. VAT
OUR TIP

Ex9SN25B2.5A, NOARK, motor starter Ex9SN25B, thermal protection 1.6–2.5A, 3P, IP20

Cat. no.: Ex9SN25B2.5A

Ex9SN25B2.5A, NOARK Ex9SN25B: adjustable motor protection 1.6–2.5A, magnetic release 33.5A, 3 poles, IP20. For motors up to 0.75kW at 400VAC (AC-3).

On request
23,13 €
excl. VAT · 27,98 € incl. VAT

3RH2131-1KB40, Siemens, SIRIUS auxiliary contactor 3RH2 for PLC, 3NO+1NC, coil 24VDC, protective diode

Cat. no.: 3RH2131-1KB40

3RH2131-1KB40, Siemens: is a low-power auxiliary contactor for interfacing with PLC outputs. It has three make and one break contact, a DC coil 24VDC and an integrated protective diode. According to…

On request
30,77 €
excl. VAT · 37,23 € incl. VAT

3RT1016-1BB42, Siemens, SIRIUS power contactor S00, AC-3 9A/400VAC, 4kW, coil 24VDC, 3NO+1NC

Cat. no.: 3RT1016-1BB42

3RT1016-1BB42, Siemens: is a power contactor of the older SIRIUS 3RT1. series. At 400VAC in category AC-3 it reaches 9A and is intended for motors up to 4kW. It has three main make contacts, one…

On request
30,92 €
excl. VAT · 37,41 € incl. VAT
OUR TIP

Ex9CH40 40 230V 50/60Hz, EMAS, installation contactor, 40A, 230V, 50Hz, 4NO, , 102420, NOARK, 40 A, 230 V AC / 50 Hz

Cat. no.: Ex9CH40 40 230V 50/60Hz

Ex9CH40 40 230V 50/60Hz EMAS – installation contactor, 40A, 230V, 50Hz, 4NO, , 102420, NOARK, 40 A, 230 V AC / 50 Hz. Key data: 3 modules, NO 4, NC 0, 230/400 V AC.. Exact technical data for…

On request
35,28 €
excl. VAT · 42,69 € incl. VAT

3RT2025-1AB00, Siemens, SIRIUS power contactor S0, 3NO, AC-3 17A/400VAC, 7.5kW, coil 24VAC/50Hz, 1NO+1NC

Cat. no.: 3RT2025-1AB00

3RT2025-1AB00, Siemens: is a three-pole SIRIUS contactor for motor circuits with a 24VAC/50Hz. coil. At 400VAC the manufacturer states a current of AC-3 17A and a motor power of 7.5kW. It contains…

On request
35,90 €
excl. VAT · 43,44 € incl. VAT

3RH2244-1BB40, Siemens, SIRIUS auxiliary contactor S00, 4NO+4NC, coil 24VDC, screw terminals

Cat. no.: 3RH2244-1BB40

3RH2244-1BB40, Siemens: The auxiliary contactor has four make and four break contacts (4NO+4NC), a 24VDC coil and screw terminals. The manufacturer's frame size is S00; it is an auxiliary contactor…

On request
37,13 €
excl. VAT · 44,92 € incl. VAT

3RN2010-1CA30, Siemens, SIRIUS thermistor motor protection relay 3RN2, 24V AC/DC, 1NO+1NC, screw terminals

Cat. no.: 3RN2010-1CA30

3RN2010-1CA30, Siemens: is a thermistor motor protection relay in a housing of width 17.5mm. It uses a 24V AC/DC supply, provides 1NO and 1NC contact, automatic RESET and two LEDs for the…

On request
45,53 €
excl. VAT · 55,09 € incl. VAT

3RT2018-1BB42, Siemens, SIRIUS power contactor, 3NO, AC-3 16A/400VAC, 7.5kW, coil 24VDC, 1NC

Cat. no.: 3RT2018-1BB42

3RT2018-1BB42, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 16A and the catalogue motor power is 7.5kW at 400VAC. Integrated…

On request
47,21 €
excl. VAT · 57,13 € incl. VAT

Prices include the recycling fee.

Contactors and motor protection

Switching a motor and protecting it are two different tasks. A contactor handles operational commands, while a protective device responds to defined fault conditions. The right choice therefore does not start with a single figure in amps, but with a description of the load, the duty cycle and the supply system. In this category you will find EMAS and NOARK motor starters, power and auxiliary contactors and accessories for their control.

Which part of the assembly are you selecting?

Separate branches are dedicated to manual control and protection of the motor feeder Motor protection (motor starters) EMAS and Motor protection (motor starters) NOARK. For operational switching and contact expansion, continue to Contactors and auxiliary contacts. The range NOARK contactors includes the Ex9C and Ex9CH series; for products of different design, always check the intended use, not just the similarity of the designation. A separate branch is formed by Siemens contactors.

When replacing an existing part, copy the complete order code including the suffix, coil data and contact configuration. Two devices of the same current size may have a different control circuit or mechanical accessories. A photo of the front helps with identification, but does not replace the rating plate, the equipment diagram and the dimension drawing.

Contactor, thermal relay and motor circuit breaker

A contactor operates its contacts electromagnetically and allows repeated remote switching. On its own it is neither motor overload protection nor a universal short-circuit breaker. A thermal overload relay monitors overload and initiates tripping via the downstream control circuit. It does not replace separate short-circuit protection; this boundary is described in Schneider Electric's explanation of the thermal relay.

A thermal-magnetic motor circuit breaker combines adjustable overload protection with a fast short-circuit release and manual operation. Other designs exist, however, so these functions cannot be attributed to every product generally called a starter. Remote operational commands are usually handled by a contactor, while the protective equipment must remain effective independently of the machine's normal program.

AC-1, AC-3 and the meaning of power in kW

AC-1 refers to non-inductive or slightly inductive loads, such as resistive heating. AC-3 describes starting a squirrel-cage motor and switching off a motor that is already running. The same contactor may therefore have a higher permissible current for AC-1 than for AC-3. The category is not a “quality grade” but a description of the switching task; see the manufacturer's explanation of categories AC-1 and AC-3.

The motor power stated for a contactor applies to the specified voltage and utilisation category. It is not the coil consumption, nor a universal limit for every motor of the same power. For frequent short jogging, plugging or demanding reversing, the corresponding duty must be verified; the usual AC-3 rating does not automatically apply to such a load. For installation relays, categories AC-7a and AC-7b. may also be decisive.

It is advisable to convert the duty cycle into a specific frequency. For example, four starts per hour in two-shift operation of eight hours each means 64 cycles per day. This total does not yet determine service life, but it provides the input for assessing switching and the maintenance plan. Also record situations where the operator repeats short commands more often than in normal production.

Protection current, coil and auxiliary contacts

For motor protection, compare the adjustable range with the motor current under the actual operating conditions and with the intended location of the protection. The upper limit of the series does not replace the range of the specific device. The run-up time and behaviour during repeated starting are also important; nuisance tripping is not solved by simply raising the setting above the permissible value.

Assess the coil control voltage separately from the main circuit voltage. The same number followed by AC or DC does not mean interchangeability. For the control output, check the coil requirements for pick-up and holding, any suppression and the drop-out time. Select auxiliary contacts according to the required NO/NC logic, the load and their belonging to the specific design series.

Short-circuit withstand is not a property of any combination

Type 1 coordination allows repair or replacement of part of the assembly after a short-circuit event. Type 2 requires suitability for further use under specified conditions; even here, zero contact welding or immediate restart cannot be promised without reservation. The difference is summarised in Schneider Electric documentation on coordination.

Verify the result for the specific protective device, contactor, any overload relay, voltage and prospective short-circuit current at the installation point. The same brand or a higher rated current of a part is no proof of coordination. The conditional short-circuit current of an assembly must also not be confused with the breaking capacity of a standalone circuit breaker.

Model example: motor and resistive heating

Consider our own calculation brief: a three-phase motor with a mechanical output of 5.5 kW, line voltage 400 V, efficiency 0.90 and power factor 0.82. The approximate current is I = P / (√3 × U × η × cos φ), i.e. approximately 10.8 A. A balanced three-phase resistive heater of 12 kW at the same voltage draws approximately 17.3 A.

The higher heating current does not by itself mean a more demanding motor switching task: we are comparing different utilisation categories. For the motor, the rated-plate current, starting and command frequency are also decisive in the actual selection; for the heater, its own operating character. The figures serve to explain the difference; they are not a selection of specific protection or wiring instructions.

Mounting and documentation for professional design

Before ordering, determine the available space, fixing method, access to terminals and cooling conditions. An add-on contact or suppressor may change the required installation space. Leave the assessment of protection, settings and commissioning of the mains circuit to a qualified person; a list of devices alone does not prove the properties of the finished control cabinet.

FAQ

Is it enough to choose a contactor by the power on the motor rating plate?

No. Add the voltage, current, utilisation category, duty cycle, control and protective combination. The same kW can lead to different device requirements.

Does an auxiliary contact confirm safe disconnection?

A standard auxiliary contact is primarily information for the control system. A safety feedback function or verification of the main contact state cannot be derived from the NO/NC designation alone.