MKS1TM-2.5, EMAS, MKS motor starter, adjustable thermal protection 1.60–2.50A
MKS1TM-2.5, EMAS: motor protection switch with thermal protection setting 1.60–2.50A. Combined thermal and magnetic protection, DIN mounting 35mm.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Contactors and motor protection – NOARK, Siemens and EMAS contactors, auxiliary contacts and motor starters for protecting motors against overload and short circuit. Choose by motor power, coil voltage and auxiliary contacts.
MKS1TM-2.5, EMAS: motor protection switch with thermal protection setting 1.60–2.50A. Combined thermal and magnetic protection, DIN mounting 35mm.
MKS1TM-4, EMAS: motor protection switch with thermal protection setting 2.50–4.00A. Combined thermal and magnetic protection, DIN mounting 35mm.
MKS1TM-6.3, EMAS: motor protection switch with thermal protection setting 4.00–6.30A. Combined thermal and magnetic protection, DIN mounting 35mm.
MKS1TM-10, EMAS: motor protection switch with thermal protection setting 6.30–10.0A. Combined thermal and magnetic protection, DIN mounting 35mm.
MKS1TM-16, EMAS: motor protection switch with thermal protection setting 10.0–16.0A. Combined thermal and magnetic protection, DIN mounting 35mm.
3RT2016-1BB42, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 9A and the catalogue motor power is 4kW at 400VAC. Integrated…
Ex9SN25B1.6A, NOARK Ex9SN25B: adjustable motor protection 1–1.6A, magnetic release 22.5A, 3 poles, IP20. For motors up to 0.37kW at 400VAC (AC-3).
Ex9SN25B6.3A, NOARK Ex9SN25B: adjustable motor protection 4–6.3A, magnetic release 78A, 3 poles, IP20. For motors up to 2.2kW at 400VAC (AC-3).
3RT2017-1BB42, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 12A and the catalogue motor power is 5.5kW at 400VAC. Integrated…
Ex9SN25B10A, NOARK Ex9SN25B: adjustable motor protection 6–10A, magnetic release 138A, 3 poles, IP20. For motors up to 4kW at 400VAC (AC-3).
HN2510NUE, EMAS: HN series power contactor, AC-3 25A, control coil 220–230VAC/50–60Hz, protection IP20. Integrated auxiliary contact 1×NO.
HN40NUE, EMAS: HN series power contactor, AC-3 40A, control coil 220–230VAC/50–60Hz, protection IP20.
3RN2000-2AA30, Siemens: The thermistor protection relay evaluates the thermal protection of the motor. It has a 24V AC/DC supply, one changeover output, automatic RESET and spring-type terminals. The…
3RT2017-1BB41, Siemens: The power contactor switches a three-phase motor load using three main make contacts. At 400VAC it has a rated current of 12A in category AC-3 and a power of 5.5kW. It is…
3RT1916-2DG21, Siemens: The Siemens SIRIUS 3RT1916-2DG21 electronic timing module provides an OFF-delay with an adjustable interval of 0.5–10s. It is intended for mounting on size S00 contactors; the…
3RT2025-1BB40, Siemens: is a three-pole SIRIUS power contactor with a 24VDC. coil. The rated operating current for AC-3 at 400VAC is 17A and the catalogue motor power is 7.5kW at 400VAC. Integrated…
3RH1911-1GA22, Siemens: is a front-mounted auxiliary contact block with two make and two break contacts. The designation 62E, snap-on fixing and screw terminals are stated directly in the Siemens…
3RT2916-1LM00, Siemens: is a suppression accessory consisting of a protective diode and a signalling LED. The manufacturer specifies it for 24–70VDC coils of contactors 3RT2.1 and auxiliary…
Ex9CH20 10 230V 50/60Hz EMAS – installation relay, 20A, 230V, 50Hz, 1NO, , 107011, NOARK, 20 A, 230 V AC. Key data: 1 module, NO 1, NC 0, IP20. Exact technical data for selecting the contactor type.
Ex9CH20 01 230V 50/60Hz, Siemens: NOARK Ex9CH20 01 230V 50/60Hz is a modular installation relay with a single break contact 1NC. For this exact variant, the manufacturer states a current of 20A, a…
3RM1920-1AA, Siemens: is an infeed terminal for the three-phase supply system of motor starters 3RM1 with screw connection.
Siemens LOGO!Contact 230, 6ED1057-4EA00-0AA0: switching module 230VAC, 3NO+1NC. Resistive loads up to 20A, motors up to 4kW.
3RM1910-1BA, Siemens: is a three-phase busbar for the common supply of 3 SIRIUS 3RM1. motor starters. It is an accessory of the supply system, not a standalone starter.
Ex9CH20 20 230V 50/60Hz EMAS – installation relay, 20A, 230V, 50Hz, 2NO, , 102399, NOARK, 20 A, 230 V AC. Key data: 1 module, NO 2, NC 0, IP20. Exact technical data for selecting the contactor type.
6ED1057-4CA00-0AA0, Siemens LOGO!Contact – switching module 24VDC, 3NO+1NC. For resistive loads up to 20A and motors up to 4kW; width 36mm.
Prices include the recycling fee.
Switching a motor and protecting it are two different tasks. A contactor handles operational commands, while a protective device responds to defined fault conditions. The right choice therefore does not start with a single figure in amps, but with a description of the load, the duty cycle and the supply system. In this category you will find EMAS and NOARK motor starters, power and auxiliary contactors and accessories for their control.
Separate branches are dedicated to manual control and protection of the motor feeder Motor protection (motor starters) EMAS and Motor protection (motor starters) NOARK. For operational switching and contact expansion, continue to Contactors and auxiliary contacts. The range NOARK contactors includes the Ex9C and Ex9CH series; for products of different design, always check the intended use, not just the similarity of the designation. A separate branch is formed by Siemens contactors.
When replacing an existing part, copy the complete order code including the suffix, coil data and contact configuration. Two devices of the same current size may have a different control circuit or mechanical accessories. A photo of the front helps with identification, but does not replace the rating plate, the equipment diagram and the dimension drawing.
A contactor operates its contacts electromagnetically and allows repeated remote switching. On its own it is neither motor overload protection nor a universal short-circuit breaker. A thermal overload relay monitors overload and initiates tripping via the downstream control circuit. It does not replace separate short-circuit protection; this boundary is described in Schneider Electric's explanation of the thermal relay.
A thermal-magnetic motor circuit breaker combines adjustable overload protection with a fast short-circuit release and manual operation. Other designs exist, however, so these functions cannot be attributed to every product generally called a starter. Remote operational commands are usually handled by a contactor, while the protective equipment must remain effective independently of the machine's normal program.
AC-1 refers to non-inductive or slightly inductive loads, such as resistive heating. AC-3 describes starting a squirrel-cage motor and switching off a motor that is already running. The same contactor may therefore have a higher permissible current for AC-1 than for AC-3. The category is not a “quality grade” but a description of the switching task; see the manufacturer's explanation of categories AC-1 and AC-3.
The motor power stated for a contactor applies to the specified voltage and utilisation category. It is not the coil consumption, nor a universal limit for every motor of the same power. For frequent short jogging, plugging or demanding reversing, the corresponding duty must be verified; the usual AC-3 rating does not automatically apply to such a load. For installation relays, categories AC-7a and AC-7b. may also be decisive.
It is advisable to convert the duty cycle into a specific frequency. For example, four starts per hour in two-shift operation of eight hours each means 64 cycles per day. This total does not yet determine service life, but it provides the input for assessing switching and the maintenance plan. Also record situations where the operator repeats short commands more often than in normal production.
For motor protection, compare the adjustable range with the motor current under the actual operating conditions and with the intended location of the protection. The upper limit of the series does not replace the range of the specific device. The run-up time and behaviour during repeated starting are also important; nuisance tripping is not solved by simply raising the setting above the permissible value.
Assess the coil control voltage separately from the main circuit voltage. The same number followed by AC or DC does not mean interchangeability. For the control output, check the coil requirements for pick-up and holding, any suppression and the drop-out time. Select auxiliary contacts according to the required NO/NC logic, the load and their belonging to the specific design series.
Type 1 coordination allows repair or replacement of part of the assembly after a short-circuit event. Type 2 requires suitability for further use under specified conditions; even here, zero contact welding or immediate restart cannot be promised without reservation. The difference is summarised in Schneider Electric documentation on coordination.
Verify the result for the specific protective device, contactor, any overload relay, voltage and prospective short-circuit current at the installation point. The same brand or a higher rated current of a part is no proof of coordination. The conditional short-circuit current of an assembly must also not be confused with the breaking capacity of a standalone circuit breaker.
Consider our own calculation brief: a three-phase motor with a mechanical output of 5.5 kW, line voltage 400 V, efficiency 0.90 and power factor 0.82. The approximate current is I = P / (√3 × U × η × cos φ), i.e. approximately 10.8 A. A balanced three-phase resistive heater of 12 kW at the same voltage draws approximately 17.3 A.
The higher heating current does not by itself mean a more demanding motor switching task: we are comparing different utilisation categories. For the motor, the rated-plate current, starting and command frequency are also decisive in the actual selection; for the heater, its own operating character. The figures serve to explain the difference; they are not a selection of specific protection or wiring instructions.
Before ordering, determine the available space, fixing method, access to terminals and cooling conditions. An add-on contact or suppressor may change the required installation space. Leave the assessment of protection, settings and commissioning of the mains circuit to a qualified person; a list of devices alone does not prove the properties of the finished control cabinet.
No. Add the voltage, current, utilisation category, duty cycle, control and protective combination. The same kW can lead to different device requirements.
A standard auxiliary contact is primarily information for the control system. A safety feedback function or verification of the main contact state cannot be derived from the NO/NC designation alone.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.