QE12-N4F, LANBAO, sensor connector M12, 4pin, straight, female
QE12-N4F LANBAO – sensor connector, M12, 4, angled, female, PVC. Connector for reliable connection of industrial sensors.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
M8 and M12 sensor connectors for field assembly on a cable – screw or solder connection, straight and angled. Choose by coding, number of contacts, cable diameter and conductor connection method.
QE12-N4F LANBAO – sensor connector, M12, 4, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE12-W4F LANBAO – sensor connector, M12, 4, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE12-N4G LANBAO – sensor connector, M12, 4, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE12-W4G LANBAO – sensor connector, M12, 4, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE12-N5G LANBAO – sensor connector, M12, 5, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE08-N4G LANBAO – sensor connector, M8, 4, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE08-W4G LANBAO – sensor connector, M8, 4, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE08-N3F LANBAO – sensor connector, M8, 3, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE08-W3F LANBAO – sensor connector, M8, 3, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE08-N3G LANBAO – sensor connector, M8, 3, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE08-W3G LANBAO – sensor connector, M8, 3, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE12-N5F LANBAO – sensor connector, M12, 5, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE12-W5F LANBAO – sensor connector, M12, 5, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE12-W5G LANBAO – sensor connector, M12, 5, angled, male, PVC. Connector for reliable connection of industrial sensors.
QE08-N4F LANBAO – sensor connector, M8, 4, angled, female, PVC. Connector for reliable connection of industrial sensors.
QE08-W4F LANBAO – sensor connector, M8, 4, angled, male, PVC. Connector for reliable connection of industrial sensors.
BCC06Z7 BALLUFF – sensor connector, M8, 4, angled, male. Connector for reliable connection of industrial sensors.
BCC06Z1 BALLUFF – sensor connector, M8, 3, angled, female. Connector for reliable connection of industrial sensors.
BCC06Z5 BALLUFF – sensor connector, M8, 4, angled, female. Connector for reliable connection of industrial sensors.
BCC0E7N BALLUFF – sensor connector, M8, 3, angled, male. Connector for reliable connection of industrial sensors.
Prices include the recycling fee.
Choose a separate connector together with the cable and the mating part. It is not enough that it can be plugged into the sensor: it must also accept the chosen cable and allow correct termination of the conductors. This category includes, for example, Lanbao QE12-N4F and Balluff BCC06Z5. When repairing, determine whether you are replacing only the termination or whether the cable is also damaged; this difference affects the scope of the subsequent check.
The first interface is the mating part: check M8 or M12, coding, the number of contacts and male or female design. The second is the contact for the conductor with the specified connection method. The third is the cable entry, which must match the outer diameter of the jacket. For an angled body, also consider the space for the cable outlet and access during assembly. Each of these points can decide usability.
Balluff for BCC06Z5 specifies a straight M8x1 female socket with four contacts and A-coding, screw connection of conductors 0.14 to 0.5 mm² and a cable diameter of 3.5 to 5 mm. These are data of a specific model. When comparing, record the range for the core and the range for the jacket in separate columns.
A pinout expresses the assignment of electrical functions to individual contacts. When reading the drawing, check whether you are looking at the mating face or the conductor connection side. Transfer contact numbers, functions and core identification to your own working sketch. Do not derive a universal function of the fourth or fifth contact just because a similar connector is used by another sensor.
For series assembly, prepare one approved wiring list and record the check of each piece. A photo of the finished connector can supplement the documentation, but may not show a hidden contact or an incorrectly assigned core. When the cable changes, compare its dimensions and termination again, even if the connector order number stays the same.
Follow the order of parts in the mounting instructions. Check which parts must be slid onto the cable before the cores are terminated. Adapt the stripping length and preparation of the stranded conductor to the contact; do not use a random value taken from another terminal. Before closing, inspect whether the individual strands have stayed in the intended place and whether the jacket enters the specified clamping area.
After assembly, assess the degree of protection of the whole connected assembly according to the instructions of both mating parts. For BCC06Z5 the manufacturer declares IP67, but this does not entitle you to mark any connected cable, open mating part or your own assembly with the same rating without a check. You cannot determine the IP class from the thread alone. A damaged or missing seal is a reason to recheck the joint.
Consider a hypothetical connector with permitted cores up to 0.5 mm² and a cable entry of 4 to 6 mm. A cable with 0.34 mm² cores but an outer diameter of 3 mm meets the first condition and fails the second. The suitability of the whole assembly therefore cannot be inferred from a smaller cross-section. These numbers are deliberately model values and do not describe the Balluff or Lanbao listed here.
On the separate assembly, check the continuity of each contact and rule out unwanted connections. Record the result with the cable label. Only then follows the sensor function test. For a new termination, choose a suitable bulk cable; if on-site assembly is not needed, also compare ready-made cables with connector.
Also check the coding, mating part and contact functions. The number of pins is not a complete wiring diagram.
Determine the value from the instructions of the selected model for the relevant joint. Do not transfer mounting values between different designs.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.