322413, SUPU, lever-operated installation connector, 3 positions, conductors 0.08–2.5mm²
322413 (SUPU): lever-operated installation connector, 3 positions, conductors 0.08–2.5mm². Overview of wiring, applications and accessories.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
SUPU and WAGO junction box connectors with lever or push-in connection for quick tool-free joining of conductors. Choose by number of conductors and cross-section.
322413 (SUPU): lever-operated installation connector, 3 positions, conductors 0.08–2.5mm². Overview of wiring, applications and accessories.
PCT-223-6 250V 32A (SUPU): six-position installation block with levers, connection 0.08–2.5mm². Overview of wiring, applications and accessories.
WAGO 222-413 WAGO – lever splicing connector for 3 conductors, max. 4 mm². Key data: all conductor types, grey. Exact technical data for selecting the terminal / terminal block type.
Prices include the recycling fee.
The category contains SUPU 322413, WAGO 222-413 and block PCT-223-6. These are specific products with their own parameters; the term “Wago-type” in the category name does not mean a common manufacturer or automatic interchangeability.
The lever makes it possible to open the spring contact, insert the prepared end of the conductor and close the contact again. The electrical connection of the individual openings is given by the design inside the body. The number of levers therefore does not say how many separate circuits can be connected. To branch one potential you need interconnected contacts; for several separate signals, on the other hand, you need them to be insulated from each other.
U SUPU 322413 three contact points and one potential are stated. The supply and two outputs thus share one node. Assess the different block PCT-223-6 as a separate type, not as an extended three-conductor connector.
When working, first draw the nodes and only then assign connector bodies to them. For example, the positive and negative poles of a DC distribution must remain separated. Inserting both into different openings of the same single-pole connector would connect them directly. Conversely, an unused opening of a common node is not a separate reserve for another signal.
WAGO 222-413 is described by the manufacturer as a three-conductor lever connector for various types of conductors. Do not transfer the parameters of this connector to similar-looking SUPU products or to the PCT block.
When selecting, look for the range for the actual core type: solid, stranded or finely stranded. Deal separately with the use of a ferrule; both its metal part and collar must fit into the intended geometry. A figure for a bare conductor is not also a figure for a conductor with a ferrule. Do not insert two ends into one contact opening without explicit permission for such a connection.
In practice, the condition of the end also matters. Stripping must not damage the strands, leave insulation under the contact or create an excessively long bare section. Hold the conductor so that it does not move when the lever is closed. A subsequent check of the seating helps reveal an end caught only by the edge of the contact; however, it does not replace electrical verification of the finished circuit.
Our own model considers two loads supplied with 24 V DC, with power ratings of 9.6 W and 14.4 W. Their steady-state currents are 0.40 A and 0.60 A, so 1.00 A flows through the common supply. To branch one potential, you need three contact points: the supply and two outputs. The same number of points is not enough to add a third load without changing the assembly. The calculation neglects inrush peaks and does not determine the permitted current of any product offered.
Before the final placement of the conductors, check the space for the levers and bends. The lid must not press on the actuator or pull the conductor out of the contact. The connector itself does not provide strain relief for the supply cable. With several connectors, keep it possible to recognise their function and check the individual ends without forcibly untangling the entire bundle.
If you need a numbered and mechanically organised interface for a larger number of cores, compare other terminals and terminal blocks. The required clarity and fastening method are decisive, not just the speed of the first connection.
Not necessarily. The number of potentials and the internal diagram are decisive, not the number of inputs. Confusing interconnected points with insulated channels is one of the most serious mistakes in selection.
The colour alone does not prove suitability for a protective circuit. Choose the product according to its intended use and connection conditions and ensure the continuity of the designed protective path. Mounting and verification of the electrical circuit is a job for a qualified person.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.