Phone +420 774 723 123 Cart · 0 · empty

Cylindrical ultrasonic sensors

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Filters
Found 453 products

BUS0050, BALLUFF, ultrasonic sensor W18M1, range 30–350 mm, 0–10V

Cat. no.: BUS0050

BUS0050 Balluff: ultrasonic sensor W18M1, range 30–350 mm, 0–10V. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0051, BALLUFF, ultrasonic sensor W18M1, range 120–1 300 mm, 0–10V

Cat. no.: BUS0051

BUS0051 Balluff: ultrasonic sensor W18M1, range 120–1 300 mm, 0–10V. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0052, BALLUFF, ultrasonic sensor M18M1, range 120–1 300 mm, 0–10V

Cat. no.: BUS0052

BUS0052 Balluff: ultrasonic sensor M18M1, range 120–1 300 mm, 0–10V. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0053, BALLUFF, ultrasonic sensor W18M1, range 120–1 300 mm, 4–20mA

Cat. no.: BUS0053

BUS0053 Balluff: ultrasonic sensor W18M1, range 120–1 300 mm, 4–20mA. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0067, BALLUFF, ultrasonic sensor M12M1, range 20–250 mm, 0–10V

Cat. no.: BUS0067

BUS0067 Balluff: ultrasonic sensor M12M1, range 20–250 mm, 0–10V. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0068, BALLUFF, ultrasonic sensor M12M1, range 40–350 mm, 0–10V

Cat. no.: BUS0068

BUS0068 Balluff: ultrasonic sensor M12M1, range 40–350 mm, 0–10V. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0069, BALLUFF, ultrasonic sensor M12M1, range 20–250 mm, 4–20mA

Cat. no.: BUS0069

BUS0069 Balluff: ultrasonic sensor M12M1, range 20–250 mm, 4–20mA. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS006A, BALLUFF, ultrasonic sensor M12M1, range 40–350 mm, 4–20mA

Cat. no.: BUS006A

BUS006A Balluff: ultrasonic sensor M12M1, range 40–350 mm, 4–20mA. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
208,75 €
excl. VAT · 252,59 € incl. VAT

BUS0047, BALLUFF, ultrasonic sensor M30E1, range 600–8 000 mm, PNP

Cat. no.: BUS0047

BUS0047 Balluff: ultrasonic sensor M30E1, range 600–8 000 mm, PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
215,51 €
excl. VAT · 260,76 € incl. VAT

BUS002R, BALLUFF, ultrasonic sensor M30M1, range 30–350 mm, 2× PNP

Cat. no.: BUS002R

BUS002R Balluff: ultrasonic sensor M30M1, range 30–350 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
229,08 €
excl. VAT · 277,19 € incl. VAT

BUS003C, BALLUFF, ultrasonic sensor M30M1, range 200–2 000 mm, 2× PNP

Cat. no.: BUS003C

BUS003C Balluff: ultrasonic sensor M30M1, range 200–2 000 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
229,08 €
excl. VAT · 277,19 € incl. VAT

BUS005H, BALLUFF, ultrasonic sensor M30M1, range 65–600 mm, 2× PNP

Cat. no.: BUS005H

BUS005H Balluff: ultrasonic sensor M30M1, range 65–600 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
229,08 €
excl. VAT · 277,19 € incl. VAT

BUS002P, BALLUFF, ultrasonic sensor M30E1, range 30–350 mm, 2× PNP

Cat. no.: BUS002P

BUS002P Balluff: ultrasonic sensor M30E1, range 30–350 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
248,45 €
excl. VAT · 300,63 € incl. VAT

BUS003H, BALLUFF, ultrasonic sensor M30E1, range 200–2 000 mm, 2× PNP

Cat. no.: BUS003H

BUS003H Balluff: ultrasonic sensor M30E1, range 200–2 000 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
248,45 €
excl. VAT · 300,63 € incl. VAT

BUS003W, BALLUFF, ultrasonic sensor M30M1, range 350–5 000 mm, 2× PNP

Cat. no.: BUS003W

BUS003W Balluff: ultrasonic sensor M30M1, range 350–5 000 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
248,45 €
excl. VAT · 300,63 € incl. VAT

BUS005J, BALLUFF, ultrasonic sensor M30E1, range 65–600 mm, 2× PNP

Cat. no.: BUS005J

BUS005J Balluff: ultrasonic sensor M30E1, range 65–600 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
248,45 €
excl. VAT · 300,63 € incl. VAT

UR18-DC60D3NO, LANBAO, ultrasonic distance sensor 30–60mm, NPN, NO, Cable 2m

Cat. no.: UR18-DC60D3NO

UR18-DC60D3NO LANBAO – ultrasonic sensor, 30–60mm, NPN, Cable 2m. Industrial product for automation, measurement and control.

On request
258,36 €
excl. VAT · 312,62 € incl. VAT

UR18-DC60D3NC, LANBAO, ultrasonic distance sensor 30–60mm, NPN, NC, Cable 2m

Cat. no.: UR18-DC60D3NC

UR18-DC60D3NC LANBAO – ultrasonic sensor, 30–60mm, NPN, Cable 2m. Industrial product for automation, measurement and control.

On request
258,36 €
excl. VAT · 312,62 € incl. VAT

UR18-DC60D3PO, LANBAO, ultrasonic distance sensor 30–60mm, PNP, NO, Cable 2m

Cat. no.: UR18-DC60D3PO

UR18-DC60D3PO LANBAO – ultrasonic sensor, 30–60mm, PNP, Cable 2m. Industrial product for automation, measurement and control.

On request
258,36 €
excl. VAT · 312,62 € incl. VAT

UR18-DC60D3PC, LANBAO, ultrasonic distance sensor 30–60mm, PNP, NC, Cable 2m

Cat. no.: UR18-DC60D3PC

UR18-DC60D3PC LANBAO – ultrasonic sensor, 30–60mm, PNP, Cable 2m. Industrial product for automation, measurement and control.

On request
258,36 €
excl. VAT · 312,62 € incl. VAT

BUS003U, BALLUFF, ultrasonic sensor M30E1, range 350–5 000 mm, 2× PNP

Cat. no.: BUS003U

BUS003U Balluff: ultrasonic sensor M30E1, range 350–5 000 mm, 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.

On request
268,87 €
excl. VAT · 325,33 € incl. VAT

Prices include the recycling fee.

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Illustrative cylindrical ultrasonic sensor in a metal threaded housing
Illustrative example of a design or application; verify the availability of the specific version on the product page.

How to choose an ultrasonic sensor M12, M18 or M30

First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.

Output and PLC connection

For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.

  • Compare the housing length, thread, space behind the connector and position of the face.
  • Verify the supply, number of contacts and wiring diagram of the exact variant.
  • Take into account the size and inclination of the target, the detection diagram and the required response.
  • When installing several sensors, check the spacing and synchronisation support.

Typical use and verification in the machine

Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.

View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.

All ultrasonic sensors and selection guide · Sensor Cables and Connectors

Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.

Selection questions

Does a larger thread M30 automatically mean a longer range than M18?

The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.

Is a switching output enough for continuous distance measurement?

A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.