Phone +420 774 723 123 Cart · 0 · empty

Cylindrical ultrasonic sensors

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Filters
Found 453 products

6066182, SICK, ultrasonic sensor UM18-21812C211, 120–1000mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5

Cat. no.: 6066182

UM18-21812C211 (6066182), SICK – ultrasonic sensor, 120–1000mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.

On request
440,65 €
excl. VAT · 533,19 € incl. VAT

6066183, SICK, ultrasonic sensor UM18-21812C212, 120–1000mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5

Cat. no.: 6066183

UM18-21812C212 (6066183), SICK – ultrasonic sensor, 120–1000mm, PNP/NPN, 4–20mA, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.

On request
440,65 €
excl. VAT · 533,19 € incl. VAT

6066184, SICK, ultrasonic sensor UM18-21812D211, 120–1000mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5

Cat. no.: 6066184

UM18-21812D211 (6066184), SICK – ultrasonic sensor, 120–1000mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.

On request
440,65 €
excl. VAT · 533,19 € incl. VAT

6066185, SICK, ultrasonic sensor UM18-21812D212, 120–1000mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5

Cat. no.: 6066185

UM18-21812D212 (6066185), SICK – ultrasonic sensor, 120–1000mm, PNP/NPN, 0–10V, IO-Link, 10–30VDC, Connector M12/5. Parameters, wiring and manufacturer documentation.

On request
440,65 €
excl. VAT · 533,19 € incl. VAT

Prices include the recycling fee.

Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.

Illustrative cylindrical ultrasonic sensor in a metal threaded housing
Illustrative example of a design or application; verify the availability of the specific version on the product page.

How to choose an ultrasonic sensor M12, M18 or M30

First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.

Output and PLC connection

For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.

  • Compare the housing length, thread, space behind the connector and position of the face.
  • Verify the supply, number of contacts and wiring diagram of the exact variant.
  • Take into account the size and inclination of the target, the detection diagram and the required response.
  • When installing several sensors, check the spacing and synchronisation support.

Typical use and verification in the machine

Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.

View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.

All ultrasonic sensors and selection guide · Sensor Cables and Connectors

Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.

Selection questions

Does a larger thread M30 automatically mean a longer range than M18?

The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.

Is a switching output enough for continuous distance measurement?

A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.