UNAM 50P3721, BAUMER, ultrasonic proximity sensor, 350–2500mm, PNP, normally closed (NC), cable 2m, IP67
UNAM 50P3721 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output PNP, normally closed (NC). Cable 2m. IP67.
Rate 24,39 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
UNAM 50P3721 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output PNP, normally closed (NC). Cable 2m. IP67.
Ultrasonic sensor, UC500-L2-E4-V15, 188194, PEPPERL+FUCHS
Ultrasonic sensor, UC2000-L2-E5-V15, 188201, PEPPERL+FUCHS
Ultrasonic sensor, UC4000-L2-E4-V15, 188206, PEPPERL+FUCHS
BUS003Y Balluff: ultrasonic sensor M30E1, range 600–8 000 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
Ultrasonic sensor, UC500-L2-E7-V15, 188197, PEPPERL+FUCHS
Ultrasonic sensor, UC2000-L2-E7-V15, 188203, PEPPERL+FUCHS
Ultrasonic sensor, UC4000-L2-E7-V15, 188209, PEPPERL+FUCHS
Ultrasonic sensor M12x1/70mm,teach, DC,0-10V,Sn:20-200mm,M12 connector4pol
Ultrasonic sensor M12x1/70mm,teach, DC,pnp,nc,200mA,Sn:10-200,M12 connector4p
Ultrasonic sensor M12x1/70mm,teach, 12-30VDC,200mA,Sn:10-100,M12-Stckr4p
Ultrasonic sensor, UC1000-18GM90-E2-IO-V1, 228189, PEPPERL+FUCHS
UNAM 50N1721/S14 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output NPN, normally open (NO). Connector M12. IP67.
UNAM 50N3721 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output NPN, normally closed (NC). Cable 2m. IP67.
Ultrasonic sensor M12x1/88mm,teach, DC,4-20mA,Sn:2-82mm,M12 connector4pol
UNAM 30N1104/S14 – ultrasonic proximity sensor BAUMER. Range 200–1500mm. Output NPN, normally open (NO). Connector M12. IP67.
UNAM 30N3104/S14 – ultrasonic proximity sensor BAUMER. Range 200–1500mm. Output NPN, normally closed (NC). Connector M12. IP67.
UNAM 30P1104/S14 – ultrasonic proximity sensor BAUMER. Range 200–1500mm. Output PNP, normally open (NO). Connector M12. IP67.
Ultrasonic sensor, UC1000-18GM90A-E2-IO-V1, 228396, PEPPERL+FUCHS
Ultrasonic sensor, UC500-30GM-2EP-IO-V15, 191242, PEPPERL+FUCHS
Ultrasonic sensor, UC2000-30GM-2EP-IO-V15, 191243, PEPPERL+FUCHS
UNAM 30N1104 – ultrasonic proximity sensor BAUMER. Range 200–1500mm. Output NPN, normally open (NO). Cable 2m. IP67.
UNAM 30N3104 – ultrasonic proximity sensor BAUMER. Range 200–1500mm. Output NPN, normally closed (NC). Cable 2m. IP67.
UC500-D1-3K-V7, ultrasonic sensor, 212371, PEPPERL+FUCHS
UNAM 12P8910/S14O Baumer: ultrasonic sensor, 10–70 mm, PNP, normally open (NO) / break function (NC), connector M12 – technical parameters and selection | TECHNOLINE
Prices include the recycling fee.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.
For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.
Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.
View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.
The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.
A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.