BUS005M, BALLUFF, ultrasonic sensor M30M1, range 65–600 mm, 0–10V / 4–20mA + PNP
BUS005M Balluff: ultrasonic sensor M30M1, range 65–600 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
Rate 24,39 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
BUS005M Balluff: ultrasonic sensor M30M1, range 65–600 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
Ultrasonic sensor M18x1/93mm, 18-30V DC,500mA,Sn:100-600/2m cable
Ultrasonic sensor M18x1/92mm/0.3mKabel, 18-30V DC,500mA,Sn:60-300,M12-St5pol
Ultrasonic sensor M18x1,90mm/0.3mKabel, 18-30V DC,500mA,Sn:100-600,M12-St5pol
Ultrasonic sensor M18x1,90mm/0.3mKabel, 18-30V DC,500mA,Sn200-1500,M12-St5p
Ultrasonic sensor M12x1/70mm,teach, DC,pnp,no,200mA,Sn:10-200,M12 connector4p
BUS002K Balluff: ultrasonic sensor M30E1, range 30–350 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS0037 Balluff: ultrasonic sensor M30E1, range 200–2 000 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS003L Balluff: ultrasonic sensor M30M1, range 350–5 000 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS005N Balluff: ultrasonic sensor M30E1, range 65–600 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS003N Balluff: ultrasonic sensor M30M1, range 200–2 000 mm, 0–10V / 4–20mA + 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS003K Balluff: ultrasonic sensor M30E1, range 350–5 000 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS0043 Balluff: ultrasonic sensor M30M1, range 600–8 000 mm, 0–10V / 4–20mA + PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
BUS0044 Balluff: ultrasonic sensor M30M1, range 350–5 000 mm, 0–10V / 4–20mA + 2× PNP. Overview of parameters, connection and suitable use at TECHNOLINE.
Ultrasonic sensor M12x1/100mm,teach, DC,pnp,no,200mA,Sn:5-70,M12 connector4p
URAM 50N1721/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output NPN, normally open (NO). Connector M12. IP67.
URAM 50N1721 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output NPN, normally open (NO). Cable 2m. IP67.
URAM 50P6121/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output PNP, normally open (NO). Connector M12. IP67.
URAM 50P6121 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output PNP, normally open (NO). Cable 2m. IP67.
URAM 50P7121/S14 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output PNP, normally closed (NC). Connector M12. IP67.
URAM 50P7121 – ultrasonic retro-reflective sensor BAUMER. Range 0–3000mm. Output PNP, normally closed (NC). Cable 2m. IP67.
UNAM 50N1721 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output NPN, normally open (NO). Cable 2m. IP67.
UNAM 50N3721/S14 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output NPN, normally closed (NC). Connector M12. IP67.
UNAM 50P1721 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output PNP, normally open (NO). Cable 2m. IP67.
UNAM 50P3721/S14 – ultrasonic proximity sensor BAUMER. Range 350–2500mm. Output PNP, normally closed (NC). Connector M12. IP67.
Prices include the recycling fee.
Cylindrical ultrasonic sensors in a threaded housing are used for non-contact object detection and distance measurement. Choose the M12, M18, M30 versions and other sizes according to the mounting space, working range and required signal to the control system. The thread size alone does not determine the range or type of output.
First determine the nearest and farthest position of the object. The entire working path must lie within the usable measuring range of the specific sensor. With a conventional diffuse-mode version, leave space in front of the face for the blind zone. Teach-in sets the evaluation limits; it does not remove this physical limit.
For presence detection or reaching a limit, choose the appropriate PNP or NPN switching output. For continuous distance, verify the analogue signal, for example 4–20 mA or 0–10 V, or the digital interface stated by the manufacturer. NO/NC function, hysteresis and window mode describe the evaluation method and are not a substitute for data on the electrical output.
Cylindrical versions are used to check distance, stack height or roll diameter. Colour and transparency are not the main criterion for ultrasound; the return of the sound echo is decisive. Orient a smooth surface according to the manufacturer's instructions; an inclined or sound-absorbing target requires a practical test.
View LANBAO UR18-CM1DI-E2 as a specific example from the range. Verify the parameters of other variants separately.
All ultrasonic sensors and selection guide · Sensor Cables and Connectors
Technical documents: Ultrasonic measuring principle – microsonic · Mounting ultrasonic sensors – microsonic.
The thread determines the mechanical design. Compare the range, blind zone and detection diagram in the datasheet of the specific model. When replacing, also check the body length and the space behind the connector.
A switching output transmits a state when a set limit is reached. For a continuous value, you need a corresponding analogue signal or a digital interface supported by both the sensor and the control system. Teach-in sets limits within the usable range.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.