Capacitive level sensors

Capacitive liquid level sensors for vessels and non-metallic pipes. Compare SICK CQF16 and LANBAO CE10/CE15 by medium, wall, mounting and required PNP/NPN output.

Filters
Found 16 products

Prices include the recycling fee.

Capacitive level sensor through a non-metallic wall

A capacitive level sensor monitors the presence of the medium at the installation point. A suitable version can monitor liquid through the wall of a plastic or other non-metallic vessel or pipe. For correct selection, compare the wall material, its thickness, the properties of the liquid and the fixing method.

LANBAO CE15SN26DPO capacitive level sensor for non-metallic pipes
LANBAO CE15SN26DPO – example of a sensor for detecting liquid in a non-metallic pipe. Product detail.

LANBAO CE10 and CE15 for detecting liquid in a pipe

For pipe applications, the range includes the CE10 and CE15, series, for example CE10SN13DPO and CE15SN26DPO. The housing is adapted for mounting on a pipe. Before choosing, check the permitted outer diameter, wall thickness and the specified position according to the documentation of the specific type.

SICK CQF16 for monitoring the level in a vessel

The SICK CQF16 series is designed for detecting water-based liquids through non-metallic walls; suitability is assessed according to the properties of the medium. You can compare CQF16-06EPOEW1 and CQF16-06EPOEP1. Choose differences in output and connection according to the complete order code.

Monitoring minimum, maximum and empty pipe

The position of the sensor determines the monitored point. Separate sensing points may be needed for minimum and maximum. Also determine the required output state with and without liquid and the link to pump or filling control.

  • Test an empty vessel or pipe as well as the state with the medium.
  • Verify the level transition in both directions and the influence of liquid residue on the wall.
  • Include the actual temperature, foam, condensation and changes in the composition of the medium.
  • Compare the supply, PNP/NPN, NO/NC function and wiring of the cable or connector.

Will one switching sensor provide continuous height or volume?

A switching level sensor reports that a limit level has been reached. For continuous height or volume, choose a suitable measuring system.

For a recommendation or a service replacement, send the complete order code and a description of the material and mounting. Help with comparing versions is available from TECHNOLINE technical support.

Manufacturer documents: LANBAO CE10, LANBAO CE15 and SICK CQF16 manual.