Phone +420 774 723 123 Cart · 0 · empty

High-Pressure Sensors

High-pressure inductive sensors withstand hydraulic oil pressure and are used to monitor the piston end position directly in the hydraulic cylinder. Choose by permissible pressure, thread, seal and medium.

Filters
Found 27 products
IN STOCK

LR12XBF15DPOB-E2, LANBAO, high-pressure inductive sensor up to 500 bar, Sn 1.5 mm, PNP, NO, connector M12/4 pins

Cat. no.: LR12XBF15DPOB-E2

LR12XBF15DPOB-E2 – LANBAO high-pressure inductive sensor up to 500 bar, −25 to +80 °C, IP68, Sn 1.5 mm, PNP, NO, connector M12/4 pins. In stock at Technoline.

In stock 5 or more pcs
45,03 €
excl. VAT · 54,48 € incl. VAT

Inductive sensor, NJ1.5-18GM-N-D, 106342, PEPPERL+FUCHS

Cat. no.: NJ1,5-18GM-N-D

Inductive sensor, NJ1.5-18GM-N-D, 106342, PEPPERL+FUCHS

On request
267,62 €
excl. VAT · 323,82 € incl. VAT

Prices include the recycling fee.

High-pressure inductive sensors for hydraulics

A high-pressure inductive sensor detects a metal part in a pressurised space, for example the position of a piston or a component of a hydraulic mechanism. Its design must withstand the pressure load and form the specified tight connection. It is a proximity sensor; it does not measure the pressure value.

Browse high-pressure sensors

LANBAO LR18X-B high-pressure inductive sensor with metal sensing part and connector
LANBAO LR18X-B. Source: LANBAO, manufacturer. Original product image from the manufacturer. Check dimensions and connection according to the order code.

Operating pressure, peaks and pressure cycles

Start with the pressure directly at the mounting location. In hydraulics, also monitor peaks when valves switch, the number of cycles and the oil temperature. A short surge can exceed the normal working pressure. A test or burst pressure stated in the documentation is not automatically a permissible value for continuous operation.

Requirement Basis for selection
Pressure load Continuous pressure, possible peaks and the nature of repeated stress.
Process connection Exact drawing, thread, seating surface, seal and specified tightening.
Medium Name of the fluid, additives, concentration and temperature; compatibility of all wetted parts.
Position detection Target material, minimum and maximum gap, position in the cylinder and speed of movement.
Electrical connection Supply, PNP/NPN, NO/NC and cable resistance along its route.

Why an IP rating does not replace a pressure specification

IP67 or IP68 describes protection against ingress under defined test conditions. Suitability as part of a hydraulic pressure chamber cannot be derived from this designation. You need an explicitly declared pressure resistance and a matching mounting interface for the specific model.

For the LR18X-B series, LANBAO specifies resistance up to 500 bar and a sensing distance of 2 mm. These figures are a guide to the series, not a universal approval for every installation. For the ordered variant, verify the pressure, temperature, sealing arrangement and operating conditions in the complete documentation.

Thread and seal form one assembly

The same thread diameter does not mean interchangeability. Pitch, screw-in length, seating geometry and seal location are decisive. In addition, the M12 electrical connector says nothing about the process connection. Design the mounting hole according to the manufacturer's drawing; do not seal the sensor in an improvised way.

Illustrative calculation: a pressure of 250 bar corresponds to 25 MPa. A force F = p × A acts on a circular area with a diameter of 8 mm, i.e. approximately 1 260 N. The actual loaded area depends on the design. The example shows the importance of correct fixing; it does not determine the load capacity of any sensor offered.

Check before start-up and during maintenance

  1. Compare the order code with the approved drawing of the mounting hole and the seal.
  2. Install with the system depressurised, following the procedure of the equipment and sensor manufacturer.
  3. After installation, carry out the prescribed leak and function test during gradual commissioning.
  4. Verify switching at the end positions and at the working temperature of the medium.
  5. During maintenance, watch for leaks, cable damage, changes in the switching position and the condition of the mechanical fixing.

If switching changes with pressure, also check the movement and deformation of mechanical parts. The symptom may not be caused by the electronics. Recording pressure, temperature and position at the moment of the fault makes it easier to distinguish the causes.

FAQ

Is a high-pressure inductive sensor a pressure sensor?

No. It monitors the presence or position of a metal target. To measure pressure, use a pressure transducer with a suitable measuring range.

Can I replace a pressure-rated model with a standard stainless steel sensor?

Only if the manufacturer of the replacement explicitly confirms the required pressure and mounting method. A stainless steel housing alone does not prove pressure resistance.

Does the maximum pressure apply at the same time as the maximum temperature?

Simultaneous limit values must be confirmed by the documentation of the specific version. Assess the entire operating range, including the medium and pressure cycles.


Choosing a design and related topics

Browse high-pressure sensors

High-temperature sensors · Chemical resistance

For a specific selection, prepare the material and dimensions of the target, the working gap, the environmental conditions and the required electrical connection. An overview can be found in the categories Special sensors and Inductive sensors.

Technical documents: LANBAO: LANBAO LR18X-B. This guide helps with selection; binding parameters, wiring and mounting are defined by the documentation of the ordered model.