Phone +420 774 723 123 Cart · 0 · empty

Rectangular Sensors

Rectangular (block-shaped) inductive sensors for detecting metal objects where a cylindrical design is not suitable. They offer a larger active face and therefore a longer switching distance, and easy mounting on flat surfaces. Choose by dimensions, range, PNP/NPN output and connection.

Filters
Found 527 products

Inductive sensor, NCB50-FP-E2-P1, 187388, PEPPERL+FUCHS

Cat. no.: NCB50-FP-E2-P1

Inductive sensor, NCB50-FP-E2-P1, 187388, PEPPERL+FUCHS

On request
210,81 €
excl. VAT · 255,08 € incl. VAT

Inductive sensor, NCB50-FP-Z2-P1, 182526, PEPPERL+FUCHS

Cat. no.: NCB50-FP-Z2-P1

Inductive sensor, NCB50-FP-Z2-P1, 182526, PEPPERL+FUCHS

On request
218,30 €
excl. VAT · 264,14 € incl. VAT

Inductive sensor, NCB50-FP-A2-P1, 119181, PEPPERL+FUCHS

Cat. no.: NCB50-FP-A2-P1

Inductive sensor, NCB50-FP-A2-P1, 119181, PEPPERL+FUCHS

On request
225,79 €
excl. VAT · 273,20 € incl. VAT

Inductive sensor, NJ50-FP-N-P1, 106504, PEPPERL+FUCHS

Cat. no.: NJ50-FP-N-P1

Inductive sensor, NJ50-FP-N-P1, 106504, PEPPERL+FUCHS

On request
231,76 €
excl. VAT · 280,43 € incl. VAT

Inductive sensor, NJ15-M1-E2-V1, 222495, PEPPERL+FUCHS

Cat. no.: NJ15-M1-E2-V1

Inductive sensor, NJ15-M1-E2-V1, 222495, PEPPERL+FUCHS

On request
233,24 €
excl. VAT · 282,22 € incl. VAT

Inductive sensor, NCB50-FP-Z5-V1, 182469, PEPPERL+FUCHS

Cat. no.: NCB50-FP-Z5-V1

Inductive sensor, NCB50-FP-Z5-V1, 182469, PEPPERL+FUCHS

On request
236,23 €
excl. VAT · 285,83 € incl. VAT

Inductive sensor, NCB50-FP-Z4-V1, 182470, PEPPERL+FUCHS

Cat. no.: NCB50-FP-Z4-V1

Inductive sensor, NCB50-FP-Z4-V1, 182470, PEPPERL+FUCHS

On request
236,23 €
excl. VAT · 285,83 € incl. VAT

Inductive sensor, NBN15-M1K-WS, 030739, PEPPERL+FUCHS

Cat. no.: NBN15-M1K-WS

Inductive sensor, NBN15-M1K-WS, 030739, PEPPERL+FUCHS

On request
246,70 €
excl. VAT · 298,51 € incl. VAT

Inductive sensor, NBN15-M1K-WO, 030740, PEPPERL+FUCHS

Cat. no.: NBN15-M1K-WO

Inductive sensor, NBN15-M1K-WO, 030740, PEPPERL+FUCHS

On request
246,70 €
excl. VAT · 298,51 € incl. VAT

NJ40-FP-SN-P1, inductive sensor, 106696, PEPPERL+FUCHS

Cat. no.: NJ40-FP-SN-P1

inductive sensor; contact NC. voltage: 8.2V; 106696; PEPPERL+FUCHS

On request
260,18 €
excl. VAT · 314,81 € incl. VAT

Inductive sensor, NBN30-FPS-UU, 236514, PEPPERL+FUCHS

Cat. no.: NBN30-FPS-UU

Inductive sensor, NBN30-FPS-UU, 236514, PEPPERL+FUCHS

On request
325,95 €
excl. VAT · 394,40 € incl. VAT

Prices include the recycling fee.

Rectangular inductive sensors: mounting and choosing the active face

A rectangular inductive sensor detects metal in the space in front of a defined active face. A flat or block-shaped body is suitable where a cylindrical thread gets in the way or where fixing with two screws is more convenient. The sensing direction and the position of the cable outlet also matter when choosing.

Choose LANBAO rectangular sensors · Compare with the cylindrical version

Principle · Selection · Mounting · Wiring · Example · Questions

LANBAO LE16 rectangular inductive sensor with mounting holes
LANBAO product image, series LE16. Source: manufacturer. Check the exact dimensions and connection in the documentation of the model.

What the sensor actually monitors

The inductive principle uses the change in the electromagnetic field when a conductive metal target approaches. Plastic, paper or glass are normally not detected this way. However, a metal insert behind a plastic part can be a target if its material, size and distance match the sensor parameters.

With a rectangular housing, do not infer the active face from the colour or the largest side alone. The dimension drawing with the sensing direction is decisive. Confusing the top and front active face is a common reason why a mechanically similar replacement does not work.

Five dimensions that decide interchangeability

Checked item Consequence of a mismatch
Width, height and length of the body The housing collides with the surrounding mechanism.
Spacing and diameter of the mounting holes The new sensor cannot be fixed in the original bracket.
Position and size of the active face The target misses the sensing zone even with identical outer dimensions.
Direction of the cable or connector outlet The connection hits the machine or the cable is bent excessively.
Required space around the face Surrounding metal affects the range or causes switching.

Mounting: the bracket is part of the sensing situation

A flush sensor may be embedded in surrounding metal under the specified conditions. For non-flush, leave the required free space. The rules also apply to a rectangular body; a flat shape by itself does not mean it can be fully embedded.

Tighten the fixing screws to the manufacturer's torque. A plastic housing in particular must not be deformed by an uneven base or overtightening. Secure the cable so that pull and vibration are not transmitted to the potted outlet. Set the gap to the active face, not to an arbitrary edge of the housing.

When placing several inductive sensors close together, check the minimum distances and any possible mutual interference. A test with only one unit switched on may not reflect the behaviour of the whole assembly.

Example: a part passes the face

At a speed of 0.5 m/s and an effective detection zone length of 8 mm, the signal lasts approximately 16 ms. A PLC input with a 30 ms filter may suppress it, even though the sensor LED briefly flashes. A better sensing geometry, a faster input or a change of filtering within the machine's requirements may be the solution.

This is an illustrative calculation t = zone length / speed. The width of the detection zone cannot automatically be equated with the width of the housing: it depends on the target, the gap and the sensor design. Verify it on the actual part before series use.

Electrical compatibility with the control system

Distinguish between PNP and NPN, NO and NC, and three-wire and other output designs. The number of connector pins does not guarantee identical wiring. For the check, prepare the wiring diagram of the specific model, the PLC input data and the required program logic. A sensor with the right mechanics but opposite NC/NO logic can change the behaviour of the whole assembly.

Quick diagnostics of unstable detection

Symptom What to check first
The sensor is permanently active A metal bracket in the active zone, incorrect mounting or NO/NC mix-up.
Detection changes when tightening Bending of the housing, shifting of the face and play in the bracket.
Small parts are occasionally missed Target size, lateral guidance, working gap and pulse length.
LED works, PLC does not respond Output type, pinout, reference potential and input filter.

Frequently asked questions from practice

Does a larger rectangular sensor always have a longer range?

Check the range in the technical data. Body size, active face and electronics design are related, but the housing size alone does not determine the Sn value.

Is a rectangular sensor suitable for a target passing from the side?

Yes, if the trajectory crosses the actual sensing zone. Verify the result at the largest gap, the smallest part and the highest speed.

Where can I find the available models?

Current products and their parameters are in the linked range of LANBAO rectangular sensors. For each model, check especially the drawing and the sensing direction.


Choosing a specific sensor

Choose LANBAO rectangular sensors · Compare with the cylindrical version

For the connection, also check sensor cables and connectors. An overview of principles and other versions can be found in the category Inductive sensors.

Technical documents: ifm: installation rules for rectangular housings. This guide describes the selection procedure; binding parameters and wiring are defined by the documentation of the ordered model.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.