Phone +420 774 723 123 Cart · 0 · empty

Industrial Relays, Solid State Switches

Industrial relays and solid state switches – electromagnetic relays with sockets, solid state relays (SSR) and modular switches. Choose by switched load, coil voltage or control, switching frequency and mounting.

Subcategories

Filters
Found 45 products
IN STOCK

RS1P11G1, EMAS, socket for 11-pin relay

Cat. no.: RS1P11G1

RS1P11G1 EMAS – socket for 11-pin relay. Exact technical data for selecting the relay socket type.

In stock 5 or more pcs
4,91 €
excl. VAT · 5,95 € incl. VAT
IN STOCK

SSS2X, EMAS, passive heat sink for SSR solid-state relays, 45×100mm, DIN mounting

Cat. no.: SSS2X

SSS2X, EMAS, passive heat sink for SSR solid-state relays, 45×100mm, DIN mounting. SSS series passive heat sink for dissipating heat from base-mounted solid-state relays.

In stock 5 or more pcs
6,14 €
excl. VAT · 7,43 € incl. VAT
OUR TIP IN STOCK

RSR30-D24-D1-02-040, RELPOL, SSR relay, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A

Cat. no.: RSR30-D24-D1-02-040

RSR30-D24-D1-02-040 RELPOL – SSR relay, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A. Exact technical data for selecting the solid-state SSR relay type.

In stock 1 ks
7,08 €
excl. VAT · 8,57 € incl. VAT
−3 % IN STOCK

PI6W-1P, RELPOL, screw socket for relay RM699BV, 1CO, width 6.2mm, DIN 35mm

Cat. no.: PI6W-1P

PI6W-1P, RELPOL: feed-through socket with screw terminals for RM699BV and RSR30, width 6.2mm, DIN rail 35mm.

In stock 5 or more pcs
9,13 € 9,42 €
excl. VAT · 11,05 € incl. VAT
OUR TIP IN STOCK

SSRP1DA012, EMAS, solid-state SSR relay, 12A, output 24–320VAC, control 4–32VDC

Cat. no.: SSRP1DA012

SSRP1DA012, EMAS, solid-state SSR relay, 12A, output 24–320VAC, control 4–32VDC. EMAS SSRP1DA012 enables contactless switching of an AC load with a DC control signal.

In stock 4 ks
10,07 €
excl. VAT · 12,18 € incl. VAT
OUR TIP IN STOCK

RE1P11DC024, EMAS, power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover

Cat. no.: RE1P11DC024

RE1P11DC024 EMAS – power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover. Exact technical data for selecting the electromagnetic relay type.

In stock 5 or more pcs
10,23 €
excl. VAT · 12,38 € incl. VAT
OUR TIP IN STOCK

RE1P11AC220, EMAS, electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A

Cat. no.: RE1P11AC220

RE1P11AC220 EMAS – electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A. Key data: RS1P11G1. Exact technical data for selecting the electromagnetic relay type.

In stock 2 ks
10,23 €
excl. VAT · 12,38 € incl. VAT
OUR TIP IN STOCK

RSR30-D24-A1-24-020, RELPOL, SSR solid-state relay RSR30, 2A, 240VAC, control 18–32VDC

Cat. no.: RSR30-D24-A1-24-020

RSR30-D24-A1-24-020, RELPOL, SSR solid-state relay RSR30, 2A, 240VAC, control 18–32VDC. Miniature SSR RSR30 switches an AC load up to 240VAC/2A with a DC control signal 18–32VDC.

In stock 5 or more pcs
10,32 €
excl. VAT · 12,48 € incl. VAT
OUR TIP IN STOCK

SSRP1DA025, EMAS, solid-state SSR relay for AC load, 25A, control 4–32VDC

Cat. no.: SSRP1DA025

SSRP1DA025, EMAS: solid-state SSR relay 25A AC-51, switches 24–320VAC by means of a control signal 4–32VDC.

In stock 4 ks
10,46 €
excl. VAT · 12,66 € incl. VAT
OUR TIP IN STOCK

PIR6W-1P-230VAC/DC, RELPOL, industrial relay, 230 V AC, 11, 12, 14

Cat. no.: PIR6W-1P-230VAC/DC

PIR6W-1P-230VAC/DC RELPOL – industrial relay, 230 V AC, 11, 12, 14. Exact technical data for selecting the electromagnetic relay type.

In stock 5 or more pcs
11,05 €
excl. VAT · 13,37 € incl. VAT
OUR TIP IN STOCK

PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm

Cat. no.: PIR6W-1P-24VAC/DC

PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm. Relpol PIR6W-1P-24VAC/DC is an interface relay with a width of 6.2mm designed for signal and control circuits.

In stock 5 or more pcs
11,05 €
excl. VAT · 13,37 € incl. VAT
OUR TIP IN STOCK

SSRP1DA040, EMAS, single-phase solid-state SSR relay, 40A, load 24–320VAC, control 4–32VDC

Cat. no.: SSRP1DA040

SSRP1DA040, EMAS, single-phase solid-state SSR relay, 40A, load 24–320VAC, control 4–32VDC. Single-phase SSR relay with DC control input for contactless switching of an AC load.

In stock 5 or more pcs
11,20 €
excl. VAT · 13,55 € incl. VAT
IN STOCK

RSR30-D24-D1-02-040 + PI6W-1P, RELPOL, SSR relay including socket, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A

Cat. no.: RSR30-D24-D1-02-040 + PI6W-1P

RSR30-D24-D1-02-040 + PI6W-1P RELPOL – SSR relay including socket, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A. Exact technical data for selecting the solid-state SSR relay…

In stock 1 ks
16,33 €
excl. VAT · 19,76 € incl. VAT
−15 % OUR TIP IN STOCK

JR-4K, TECHNOLINE, four-channel contactless thyristor AC switch, SCR, 230VAC/3.15A

Cat. no.: JR-4K

JR-4K TECHNOLINE – four-channel contactless thyristor AC switch, SCR, 230VAC/3.15A. Key data: JR-4K, SCR - thyristor, 4. Exact technical data for selecting the switching module type.

In stock 5 or more pcs
17,13 € 20,15 €
excl. VAT · 20,72 € incl. VAT
−15 % OUR TIP IN STOCK

JR-4J, TECHNOLINE, four-channel MOSFET switching module for DC loads, PNP, 24VDC, 5A/channel with resistive load

Cat. no.: JR-4J

JR-4J, TECHNOLINE: four-channel MOSFET module with PNP outputs for loads 12–24VDC; control 24VDC, resistive load up to 5A/channel.

In stock 5 or more pcs
17,85 € 21,00 €
excl. VAT · 21,60 € incl. VAT
IN STOCK

RSR30-D24-A1-24-020 + PI6W-1P, RELPOL, SSR relay assembly RSR30, 2A, 240VAC, with socket

Cat. no.: RSR30-D24-A1-24-020 + PI6W-1P

RSR30-D24-A1-24-020 + PI6W-1P, RELPOL, SSR relay assembly RSR30, 2A, 240VAC, with socket. The assembly contains miniature solid-state relay RSR30 and plug-in socket PI6W-1P for serviceable mounting.

In stock 5 or more pcs
19,24 €
excl. VAT · 23,28 € incl. VAT
−10 % OUR TIP IN STOCK

JR-4L, TECHNOLINE, four-channel relay switching module for PLC, 24VDC, 10A/250VAC

Cat. no.: JR-4L

JR-4L, TECHNOLINE, four-channel relay switching module for PLC, 24VDC, 10A/250VAC. Relay interface JR-4L converts four PLC output signals 24VDC into independent relay contacts.

In stock 5 or more pcs
25,50 € 28,33 €
excl. VAT · 30,86 € incl. VAT

Prices include the recycling fee.

Industrial relays, contactless switches

Selecting a switching element starts with a description of the circuit: what is to be switched on, how often, and what the equipment should do after the command is removed. Record the control parameters and the load separately. Do not use the coil or input voltage as the load voltage. This gives you documentation for comparing truly interchangeable components.

Deciding between a contact and a semiconductor

For assemblies with mechanical contacts, continue to electromagnetic relays. Several output channels on a common module are handled by modular switches. A separate branch is formed by SSR solid-state relays. Choose these groups by function, not by similarity of the housing. For each branch, determine in advance whether you need a separate part or an assembly.

OMRON's explanation of the relay principle describes electromagnetic operation of a mechanical contact. The contact circuit and the coil have different roles. In an SSR, switching is taken over by a semiconductor; the SSR technical glossary therefore separates the input parameters, switched current and off-state current.

Principle of load assessment

In the brief, state whether it is resistive heating, a solenoid, a motor or the supply input of electronics. Then look up the corresponding load conditions in the documentation of the selected type. A maximum figure in amps without the voltage and character of the circuit does not provide complete documentation. When comparing, create separate rows for the steady-state current, switch-on, switch-off and the required frequency.

When assembling the controls, continue with the guide to complete relays with socket. The design must determine which device performs normal switching and which handles faults. The presence of a relay by itself does not describe the protective function of the equipment. Similarly, an additional coil protection element is not information about protection of the connected load.

Author's model example: the same current

Consider an ideal resistive load of 460 W at 230 V and a DC solenoid with a steady-state power of 48 W at 24 V. In both cases the steady-state current is 2 A. This is an author's brief, not the parameters of products in this category. The identical result allows the consumption to be compared, not the same switching limit to be applied automatically.

In two columns of the selection table, therefore add the type of supply, the character of the load and the current waveform. If one column remains empty, calculation from the power will not replace the missing data. The purpose of the example is to formulate a complete enquiry; it does not determine a specific relay, protection or wiring.

Mounting and part compatibility

For the plug-in version, check the identification of the relay, socket and add-on modules together. Include space for conductors, part replacement and access to markings in the layout. For an SSR, also add the cooling conditions to the documentation; the load capacity definition in the OMRON glossary mentioned explicitly takes them into account. Free space on the rail alone is not a thermal assessment.

Diagnostics based on three separate observations

Divide the service record into the command from the control system, the state of the switching element and the response of the load. State at which step the expectation differs from reality. Add the control cabinet temperature and the time since start-up to the record. Checks of electrical circuits and their safeguarding belong in the procedure of a qualified person according to the specific equipment.

FAQ

Is the same number of contacts enough for a replacement?

No. Also compare the control, contact diagram, load, sockets and required accessories. The replacement part must meet the entire brief.

Does an indicator lamp prove that the load is safely switched off?

No. OMRON warns of the possibility of a short-circuit failure of an SSR, in which the output remains conductive. Ensuring a safe state must be addressed by the equipment design.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.