R4N-2014-23-5230-WT, RELPOL, industrial relay 4× changeover contact, coil 230VAC, 6A AC-1
R4N-2014-23-5230-WT, RELPOL: industrial relay with four changeover contacts 4CO and a 230VAC coil; contact current AC-1 6A.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Industrial relays and solid state switches – electromagnetic relays with sockets, solid state relays (SSR) and modular switches. Choose by switched load, coil voltage or control, switching frequency and mounting.
R4N-2014-23-5230-WT, RELPOL: industrial relay with four changeover contacts 4CO and a 230VAC coil; contact current AC-1 6A.
RS1P11G1 EMAS – socket for 11-pin relay. Exact technical data for selecting the relay socket type.
SSS2X, EMAS, passive heat sink for SSR solid-state relays, 45×100mm, DIN mounting. SSS series passive heat sink for dissipating heat from base-mounted solid-state relays.
RSR30-D24-D1-02-040 RELPOL – SSR relay, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A. Exact technical data for selecting the solid-state SSR relay type.
PI6W-1P, RELPOL: feed-through socket with screw terminals for RM699BV and RSR30, width 6.2mm, DIN rail 35mm.
SSRP1DA012, EMAS, solid-state SSR relay, 12A, output 24–320VAC, control 4–32VDC. EMAS SSRP1DA012 enables contactless switching of an AC load with a DC control signal.
RE1P11DC024 EMAS – power relay 3CO, 11 pins, coil 24 V DC, contacts 10 A / 250 V AC, 3CO / 3 changeover. Exact technical data for selecting the electromagnetic relay type.
RE1P11AC220 EMAS – electromagnetic relay, 3 contacts(11pin), 10A, coil 230VAC, 230 V AC, 10 A. Key data: RS1P11G1. Exact technical data for selecting the electromagnetic relay type.
RSR30-D24-A1-24-020, RELPOL, SSR solid-state relay RSR30, 2A, 240VAC, control 18–32VDC. Miniature SSR RSR30 switches an AC load up to 240VAC/2A with a DC control signal 18–32VDC.
SSRP1DA025, EMAS: solid-state SSR relay 25A AC-51, switches 24–320VAC by means of a control signal 4–32VDC.
PIR6W-1P-230VAC/DC RELPOL – industrial relay, 230 V AC, 11, 12, 14. Exact technical data for selecting the electromagnetic relay type.
PIR6W-1P-24VAC/DC, RELPOL, slim interface relay 24VAC/DC, 1CO, 6A, 6.2mm. Relpol PIR6W-1P-24VAC/DC is an interface relay with a width of 6.2mm designed for signal and control circuits.
SSRP1DA040, EMAS, single-phase solid-state SSR relay, 40A, load 24–320VAC, control 4–32VDC. Single-phase SSR relay with DC control input for contactless switching of an AC load.
RSR30-D24-D1-02-040 + PI6W-1P RELPOL – SSR relay including socket, control voltage 18-32V DC, switched load 24VDC-2A, 18–32 V DC, 2 A. Exact technical data for selecting the solid-state SSR relay…
JR-4K TECHNOLINE – four-channel contactless thyristor AC switch, SCR, 230VAC/3.15A. Key data: JR-4K, SCR - thyristor, 4. Exact technical data for selecting the switching module type.
JR-4J, TECHNOLINE: four-channel MOSFET module with PNP outputs for loads 12–24VDC; control 24VDC, resistive load up to 5A/channel.
RSR30-D24-A1-24-020 + PI6W-1P, RELPOL, SSR relay assembly RSR30, 2A, 240VAC, with socket. The assembly contains miniature solid-state relay RSR30 and plug-in socket PI6W-1P for serviceable mounting.
JR-4L, TECHNOLINE, four-channel relay switching module for PLC, 24VDC, 10A/250VAC. Relay interface JR-4L converts four PLC output signals 24VDC into independent relay contacts.
JR-8J, TECHNOLINE, eight-channel MOSFET transistor module for PLC, 24VDC, 5A/channel.
RM84-2012-25-1024, RELPOL: miniature relay 2CO with coil 24VDC, contact load AC-1 8A/250VAC.
Prices include the recycling fee.
Selecting a switching element starts with a description of the circuit: what is to be switched on, how often, and what the equipment should do after the command is removed. Record the control parameters and the load separately. Do not use the coil or input voltage as the load voltage. This gives you documentation for comparing truly interchangeable components.
For assemblies with mechanical contacts, continue to electromagnetic relays. Several output channels on a common module are handled by modular switches. A separate branch is formed by SSR solid-state relays. Choose these groups by function, not by similarity of the housing. For each branch, determine in advance whether you need a separate part or an assembly.
OMRON's explanation of the relay principle describes electromagnetic operation of a mechanical contact. The contact circuit and the coil have different roles. In an SSR, switching is taken over by a semiconductor; the SSR technical glossary therefore separates the input parameters, switched current and off-state current.
In the brief, state whether it is resistive heating, a solenoid, a motor or the supply input of electronics. Then look up the corresponding load conditions in the documentation of the selected type. A maximum figure in amps without the voltage and character of the circuit does not provide complete documentation. When comparing, create separate rows for the steady-state current, switch-on, switch-off and the required frequency.
When assembling the controls, continue with the guide to complete relays with socket. The design must determine which device performs normal switching and which handles faults. The presence of a relay by itself does not describe the protective function of the equipment. Similarly, an additional coil protection element is not information about protection of the connected load.
Consider an ideal resistive load of 460 W at 230 V and a DC solenoid with a steady-state power of 48 W at 24 V. In both cases the steady-state current is 2 A. This is an author's brief, not the parameters of products in this category. The identical result allows the consumption to be compared, not the same switching limit to be applied automatically.
In two columns of the selection table, therefore add the type of supply, the character of the load and the current waveform. If one column remains empty, calculation from the power will not replace the missing data. The purpose of the example is to formulate a complete enquiry; it does not determine a specific relay, protection or wiring.
For the plug-in version, check the identification of the relay, socket and add-on modules together. Include space for conductors, part replacement and access to markings in the layout. For an SSR, also add the cooling conditions to the documentation; the load capacity definition in the OMRON glossary mentioned explicitly takes them into account. Free space on the rail alone is not a thermal assessment.
Divide the service record into the command from the control system, the state of the switching element and the response of the load. State at which step the expectation differs from reality. Add the control cabinet temperature and the time since start-up to the record. Checks of electrical circuits and their safeguarding belong in the procedure of a qualified person according to the specific equipment.
No. Also compare the control, contact diagram, load, sockets and required accessories. The replacement part must meet the entire brief.
No. OMRON warns of the possibility of a short-circuit failure of an SSR, in which the output remains conductive. Ensuring a safe state must be addressed by the equipment design.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.