G4-1052, RELPOL, retaining clip
G4-1052 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Industrial relays and solid state switches – electromagnetic relays with sockets, solid state relays (SSR) and modular switches. Choose by switched load, coil voltage or control, switching frequency and mounting.
G4-1052 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
RS2.M00.AC, EMAS: plastic retaining clip designed for mechanically securing a compatible relay in a socket of series RS2.
GZT80-0040 RELPOL – retaining clip. Exact technical data for selecting the relay accessory type.
The QIANJI plug-in socket DYF14A is intended for 14-pin industrial relays with four changeover contacts. It allows the relay to be connected in a control cabinet and makes its possible replacement…
RS2.KY.01.DC EMAS – LED module with green LED and protective diode 6–24V DC. Key data: Value, RS2.KY.01.DC, LED module with protective diode. Exact technical data for selecting the relay accessory…
RELPOL socket GZT4B for connecting a R4N series plug-in relay in a control cabinet. It is intended for the fourteen-pin relay version with four changeover contacts.
M91G, RELPOL, indication and protection module for relay coils, 6–24VAC/DC, green LED. Module M91G indicates coil energisation with a green LED and limits voltage peaks when it is switched off.
M93G RELPOL – protection module for relays. Key data: 230 V AC. Exact technical data for selecting the relay accessory type.
RS2.RC.05 EMAS – LED module with green LED and protective diode 110-230V AC. Key data: Value, RS2.RC.05, LED module with protective diode. Exact technical data for selecting the relay accessory type.
RE2.U2C.DC024.S0, EMAS, power relay for PCB, 2 changeover contacts, coil 24VDC, 8A. Eight-pin relay of series RE2 U2C with two independent changeover contacts for soldering into a PCB or use with a…
RM84-2012-35-1012, RELPOL, miniature relay 2×CO, coil 12VDC, contacts 8A/250VAC AC-1. Relay RM84 with two changeover contacts and a 12VDC coil for switching control circuits.
RM84-2012-35-1024 RELPOL – electromagnetic relay, 24V DC, 2 changeover contacts, 12 A. Key data: RM 84, GZM80, 8 A / 250 VAC. Exact technical data for selecting the electromagnetic relay type.
HH54P QIANJI – electromagnetic relay, 24V DC, 4 changeover contacts, 5A. Key data: HH54P, DYF14A, 5 A / 24 VDC. Exact technical data for selecting the electromagnetic relay type.
ZG20-1 RELPOL – jumper comb for relays. Key data: 20, 35A. Exact technical data for selecting the relay accessory type.
ZG20-3 RELPOL – jumper comb for relays. Key data: 20, 35A. Exact technical data for selecting the relay accessory type.
RS2.M2CO.08V.S0, EMAS, DIN-rail relay socket for PCB relays RE2, 4/5/6/8 pins, 250VAC. Socket RS2.M2CO.08V.S0 is designed for DIN-rail mounting and for inserting suitable power relays RE2 with…
GZM80, RELPOL, plug-in socket for miniature relays, 2 changeover contacts, DIN. Relpol GZM80 is a compact screw socket for selected series of miniature relays RM84, RM85 and RM87L/RM87P.
GZT92, RELPOL: screw socket for DIN 35mm for relays RM87N and RM87N Sensitive, rated load 12A/300VAC.
GZT4, RELPOL, plug-in socket for relay R4N, 4 changeover contacts, DIN. Socket GZT4 is used for connecting four-pole industrial relays R4N and allows the relay to be replaced without disconnecting…
RM87N-2011-25-1024, RELPOL, miniature electromagnetic relay RM87N, 1CO, coil 24VDC, 12A. Miniature relay RM87N-2011-25-1024 has one changeover contact and a 24VDC. coil
RM87N-2011-35-1024, RELPOL, miniature electromagnetic relay RM87N, 1CO, coil 24VDC, 12A. Miniature relay RM87N-2011-35-1024 has one changeover contact and a 24VDC. coil
RE2.U2C.AC230.S0, EMAS: miniature relay for PCB mounting, coil 230VAC, two changeover contacts 2CO, rated current 8A.
RM84-2012-25-5230, RELPOL: miniature relay 2CO with coil 230VAC, contact load AC-1 8A/250VAC.
RM699BV-3011-85-1024, RELPOL, miniature relay 1×CO, coil 24VDC, contacts 6A/250VAC AC-1. Slim relay RM699BV in version 1×CO with a 24VDC coil for the interface between electronics and the switched…
R4N-2014-23-1024 RELPOL – electromagnetic relay, 24V DC, 4 changeover contacts, 12A. Key data: R4, GZT 4, 6 A / 24 VDC. Exact technical data for selecting the electromagnetic relay type.
Prices include the recycling fee.
Selecting a switching element starts with a description of the circuit: what is to be switched on, how often, and what the equipment should do after the command is removed. Record the control parameters and the load separately. Do not use the coil or input voltage as the load voltage. This gives you documentation for comparing truly interchangeable components.
For assemblies with mechanical contacts, continue to electromagnetic relays. Several output channels on a common module are handled by modular switches. A separate branch is formed by SSR solid-state relays. Choose these groups by function, not by similarity of the housing. For each branch, determine in advance whether you need a separate part or an assembly.
OMRON's explanation of the relay principle describes electromagnetic operation of a mechanical contact. The contact circuit and the coil have different roles. In an SSR, switching is taken over by a semiconductor; the SSR technical glossary therefore separates the input parameters, switched current and off-state current.
In the brief, state whether it is resistive heating, a solenoid, a motor or the supply input of electronics. Then look up the corresponding load conditions in the documentation of the selected type. A maximum figure in amps without the voltage and character of the circuit does not provide complete documentation. When comparing, create separate rows for the steady-state current, switch-on, switch-off and the required frequency.
When assembling the controls, continue with the guide to complete relays with socket. The design must determine which device performs normal switching and which handles faults. The presence of a relay by itself does not describe the protective function of the equipment. Similarly, an additional coil protection element is not information about protection of the connected load.
Consider an ideal resistive load of 460 W at 230 V and a DC solenoid with a steady-state power of 48 W at 24 V. In both cases the steady-state current is 2 A. This is an author's brief, not the parameters of products in this category. The identical result allows the consumption to be compared, not the same switching limit to be applied automatically.
In two columns of the selection table, therefore add the type of supply, the character of the load and the current waveform. If one column remains empty, calculation from the power will not replace the missing data. The purpose of the example is to formulate a complete enquiry; it does not determine a specific relay, protection or wiring.
For the plug-in version, check the identification of the relay, socket and add-on modules together. Include space for conductors, part replacement and access to markings in the layout. For an SSR, also add the cooling conditions to the documentation; the load capacity definition in the OMRON glossary mentioned explicitly takes them into account. Free space on the rail alone is not a thermal assessment.
Divide the service record into the command from the control system, the state of the switching element and the response of the load. State at which step the expectation differs from reality. Add the control cabinet temperature and the time since start-up to the record. Checks of electrical circuits and their safeguarding belong in the procedure of a qualified person according to the specific equipment.
No. Also compare the control, contact diagram, load, sockets and required accessories. The replacement part must meet the entire brief.
No. OMRON warns of the possibility of a short-circuit failure of an SSR, in which the output remains conductive. Ensuring a safe state must be addressed by the equipment design.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.