Phone +420 774 723 123 Cart · 0 · empty

IDEC 5/12/24V DC Power Supplies

IDEC 5, 12 and 24 V DC DIN rail power supplies, including the compact PS5R series. Choose by output voltage and current, dimensions and operating temperature.

Filters
Found 9 products

PS5R-VB24, IDEC, switched-mode DIN-rail power supply, 15W, 24VDC/0.65A

Cat. no.: PS5R-VB24

PS5R-VB24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 15W, 24VDC/0.65A, input 100–240VAC. Width 22.5mm. For PLCs, HMIs, sensors, relays and other industrial…

On request
47,73 €
excl. VAT · 57,76 € incl. VAT

PS5R-VB05, IDEC, switched-mode DIN-rail power supply, 10W, 5VDC/2A

Cat. no.: PS5R-VB05

PS5R-VB05, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 10W, 5VDC/2A, input 100–240VAC. Width 22.5mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
47,73 €
excl. VAT · 57,76 € incl. VAT

PS5R-VB12, IDEC, switched-mode DIN-rail power supply, 15W, 12VDC/1.3A

Cat. no.: PS5R-VB12

PS5R-VB12, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 15W, 12VDC/1.3A, input 100–240VAC. Width 22.5mm. For PLCs, HMIs, sensors, relays and other industrial…

On request
47,73 €
excl. VAT · 57,76 € incl. VAT

PS5R-VC12, IDEC, switched-mode DIN-rail power supply, 30W, 12VDC/2.5A

Cat. no.: PS5R-VC12

PS5R-VC12, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 30W, 12VDC/2.5A, input 100–240VAC. Width 22.5mm. For PLCs, HMIs, sensors, relays and other industrial…

On request
64,84 €
excl. VAT · 78,46 € incl. VAT

PS5R-VC24, IDEC, switched-mode DIN-rail power supply, 30W, 24VDC/1.3A

Cat. no.: PS5R-VC24

PS5R-VC24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 30W, 24VDC/1.3A, input 100–240VAC. Width 22.5mm. For PLCs, HMIs, sensors, relays and other industrial…

On request
64,84 €
excl. VAT · 78,46 € incl. VAT

PS5R-VD24, IDEC, switched-mode DIN-rail power supply, 60W, 24VDC/2.5A

Cat. no.: PS5R-VD24

PS5R-VD24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 60W, 24VDC/2.5A, input 100–240VAC. Width 36mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
78,36 €
excl. VAT · 94,81 € incl. VAT

PS5R-VE24, IDEC, switched-mode DIN-rail power supply, 90W, 24VDC/3.75A

Cat. no.: PS5R-VE24

PS5R-VE24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 90W, 24VDC/3.75A, input 100–240VAC. Width 36mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
93,22 €
excl. VAT · 112,79 € incl. VAT

PS5R-VF24, IDEC, switched-mode DIN-rail power supply, 120W, 24VDC/5A

Cat. no.: PS5R-VF24

PS5R-VF24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 120W, 24VDC/5A, input 100–240VAC. Width 46mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
123,39 €
excl. VAT · 149,30 € incl. VAT

PS5R-VG24, IDEC, switched-mode DIN-rail power supply, 240W, 24VDC/10A

Cat. no.: PS5R-VG24

PS5R-VG24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 240W, 24VDC/10A, input 100–240VAC. Width 60mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
176,54 €
excl. VAT · 213,62 € incl. VAT

Prices include the recycling fee.

IDEC 5/12/24V DC power supplies

The name of this category denotes different voltage variants, not three outputs of each power supply. The following guide explains how to choose a suitable voltage, assess the wiring and prepare a replacement. The IDEC series mentioned serve as examples from the manufacturer's documentation; their mention does not confirm current availability in this branch.

The voltage variant is the basis of compatibility

A regulated power supply should maintain the voltage required by the load under changes in permissible load. A higher current capacity will not make a 24V version a suitable supply for 5V electronics. For each device, verify the rated voltage, permissible tolerance, polarity and any separate supply for power outputs.

As an example of the manufacturer's variants, PS5R-VB05, PS5R-VB12 and PS5R-VB24. can be used. Their differences are given in the IDEC catalogue sheet PS5R-V. When working with an older power supply, distinguish the exact generation and suffixes; the designation PS5R alone is not a complete replacement specification.

Mounting position and derating

The possibility of rotating the power supply does not mean the same usable power in all positions. Data sheet PS5R-V contains separate curves according to version, mounting and input voltage. Before selecting, compare the specific arrangement with the Operating Temperature vs. Output Current section in that data sheet. Do not derive full load from the upper operating temperature stated in the series overview.

Include not only the housing but also trunking, conductors and access to the terminals in the installation. A replacement with a different connection method may require modification of the conductor ends or their length. Verify the permissible cross-section, termination and tightening torque according to the exact model; do not create a common mounting value for the whole brand.

Model example: voltage drop in a 5V branch

Assume electronics requiring at least 4.75 V and a current of 1.4 A. If the entire supply loop including connections has a model resistance of 0.25 Ω, a drop of 0.35 V occurs. Of exactly 5.00 V at the power supply, only 4.65 V then remains at the load. Even a sufficient current reserve does not solve this problem by itself. The figures are an illustrative design example, not IDEC technical data.

In such a situation, assess shortening the route, a more suitable cross-section or placing the power supply closer to the load. Merely increasing the setting may cause overvoltage on another, less loaded branch. Also carry out check measurements during start-up, when an ordinary slow reading may not capture a short dip.

Frequently asked questions and limitations

Can two PS5R-V be connected in parallel to increase the current?

The PS5R-V documentation does not permit this method of increasing power. It separately describes backup connection; this is not the same as adding rated currents. Distinguish the Parallel Operation and Backup Operation sections in the catalogue sheet. The conclusion applies to the stated series, not automatically to all IDEC power supplies.

Where do I start if I don't have an order number yet?

Create a voltage and current balance according to the guide Power supplies. To compare the requirements of a 5V branch, you can also open the catalogue 6EP3311-6SB00-0AY0 of another brand; the same output voltage does not make it a direct IDEC replacement.

Cookies on this website