CPF81D-7NN11, Endress+Hauser, Orbipac digital pH sensor
CPF81D-7NN11 Endress+Hauser – digital pH sensor. Industrial product for automation, measurement and control.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Endress+Hauser pH and conductivity measurement – Orbipac CPF81D pH electrodes and Smartec CLD134 conductivity transmitter. Choose by medium, temperature and required output.
CPF81D-7NN11 Endress+Hauser – digital pH sensor. Industrial product for automation, measurement and control.
CLD134-PMV558AA1 Endress+Hauser – conductivity measuring device. Industrial product for automation, measurement and control.
Prices include the recycling fee.
Process pH measurement helps monitor the acidity and alkalinity of an aqueous medium, for example in water treatment or neutralisation control. Selection starts with the properties of the solution and the method of installation. The expected pH is not enough: temperature, pressure, solid particles, the possibility of coating and the required response are also important.
This category offers the Endress+Hauser Orbipac CPF81D-7NN11 and Smartec CLD134-PMV558AA1. The first is used to measure pH, the second to measure conductivity. These are not two interchangeable methods for the same quantity; for selection, first determine which property of the liquid the control system should actually evaluate.
pH is a logarithmic expression of hydrogen ion activity. A difference of one unit means a tenfold activity ratio, not a tenfold required amount of neutralising agent. Reagent consumption also depends on the buffer capacity and composition of the solution. This results in a practical limitation: the same initial pH value does not guarantee the same dose for two different liquids.
Smartec CLD134 works inductively and evaluates the conductivity of the medium. Conductivity characterises the ability of a solution to conduct electric current; it is affected by the ions present and by temperature. Without knowing the specific mixture, pH cannot be unambiguously calculated from it, nor can it be determined which substance caused the change.
Orbipac CPF81D has a digital Memosens interface. It needs an appropriate connection and a compatible evaluation device; it is not a standalone universal 4–20 mA output. The manufacturer distinguishes NN and LH versions with different temperature limits, so the maximum of one variant cannot be transferred to the other.
With controlled neutralisation, allow for mixing time. Dosing too quickly based on a not yet stabilised measurement leads to overshoot and a subsequent opposite intervention. The measuring point, dosing point and controller settings must therefore be assessed as a whole, even if each part meets its parameters on its own.
When designing the measuring point, verify the materials in contact with the liquid, the fitting seals, mechanical protection of the sensitive glass and the possibility of removal for service. The sensor must measure a representatively mixed sample, not a fresh stream of concentrated chemical right next to the dosing nozzle. Direct immersion and a flow-through assembly have different requirements for maintenance and time delay.
Temperature compensation of the electrode response does not mean automatic conversion of the actual pH of any liquid to a reference temperature. Endress+Hauser service manual explicitly distinguishes the temperature change of the measured solution from ordinary automatic compensation. Laboratory and operational measurements should therefore be compared under comparable temperature conditions.
For calibration, use suitable reference buffers and their values at the actual temperature. Prevent residues of the previous solution from being carried over into the next buffer and wait for stabilisation. Two points allow the slope and offset of the response to be assessed; repeated checking of a single point may not reveal a change in slope. Store the results with the date, temperature, solutions used and the state of the sensor before and after cleaning.
Imagine two model potential values at the same temperature of 25 °C: in buffer pH 7 it is 2 mV and in buffer pH 4 it is 176 mV. The slope is (176 − 2)/(7 − 4) = 58 mV per pH unit. The example shows the calculation from a pair of points, not a prescribed tolerance CPF81D. Acceptance of the calibration is decided by the rules of the system used and the requirements of the application; the calculated number alone does not verify the entire measuring chain.
A coating can change contact with the medium and slow down stabilisation. Compare the sensor in a reference solution and only then look for a change in the process. Determine the cleaning interval according to actual fouling, not according to a fixed rule for all liquids.
For stable control, mixing, transport delay and load changes must be taken into account. Information on the dosed volume can be supplemented by suitable Flow sensors. Further links between measuring systems can be found in the overview Process Sensors.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.