Phone +420 774 723 123 Cart · 0 · empty

Incremental Rotary Encoders

Incremental rotary encoders for measuring speed, velocity and position. Choose by resolution (pulses per revolution), shaft diameter and type, flange and output (HTL, TTL, push-pull).

Filters
Found 10 products

IRC305/2500PB, LARM, incremental rotary encoder

Cat. no.: IRC305/2500PB

IRC305/2500PB LARM – incremental rotary encoder, cable 1m. Industrial product for automation, measurement and control.

On request
185,48 €
excl. VAT · 224,43 € incl. VAT

IRC320/512PB, LARM, incremental rotary encoder

Cat. no.: IRC320/512PB

IRC320/512PB LARM – incremental rotary encoder, push/pull, cable 1m. Industrial product for automation, measurement and control.

On request
209,75 €
excl. VAT · 253,80 € incl. VAT

IRC305/4096KA, LARM, incremental rotary encoder

Cat. no.: IRC305/4096KA

IRC305/4096KA LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
209,75 €
excl. VAT · 253,80 € incl. VAT

IRC125/1250KB, LARM, incremental rotary encoder

Cat. no.: IRC125/1250KB

IRC125/1250KB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
217,08 €
excl. VAT · 262,66 € incl. VAT

IRC300/1000KB, LARM, incremental rotary encoder

Cat. no.: IRC300/1000KB

IRC300/1000KB LARM – incremental rotary encoder, push/pull. Industrial product for automation, measurement and control.

On request
219,00 €
excl. VAT · 264,99 € incl. VAT

IRC120/1250KA, LARM, incremental rotary encoder

Cat. no.: IRC120/1250KA

IRC120/1250KA LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
223,09 €
excl. VAT · 269,94 € incl. VAT

IRC302/1000KB, LARM, incremental rotary encoder

Cat. no.: IRC302/1000KB

IRC302/1000KB LARM – incremental rotary encoder, PNP. Industrial product for automation, measurement and control.

On request
232,30 €
excl. VAT · 281,09 € incl. VAT

IRC315/6000KB, LARM, incremental rotary encoder

Cat. no.: IRC315/6000KB

IRC315/6000KB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
242,01 €
excl. VAT · 292,83 € incl. VAT

IRC325/5000KBB, LARM, incremental rotary encoder

Cat. no.: IRC325/5000KBB

IRC325/5000KBB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
247,58 €
excl. VAT · 299,57 € incl. VAT

IRC310/5000KB, LARM, incremental rotary encoder

Cat. no.: IRC310/5000KB

IRC310/5000KB LARM – incremental rotary encoder, push/pull. Industrial product for automation, measurement and control.

On request
265,22 €
excl. VAT · 320,91 € incl. VAT

Prices include the recycling fee.

Incremental rotary encoders

A rotary incremental encoder monitors shaft rotation using incremental signals. When replacing the original device, you need to preserve the relationship between movement, number of increments and the program scale. For a new design, also add the highest operating speed and the reference requirement.

The range includes, for example, IRC305/2500PB, IRC305/4096KA and IRC320/512PB from LARM. These order codes are not mutually interchangeable. The basic principle of A/B/Z and counter modes is explained by the guide Incremental Encoders; here the procedure for choosing the specific mechanical and electrical variant is essential.

Verify mechanical interchangeability according to the drawing

For the LARM IRC300–325 series, the manufacturer distinguishes a 6 mm solid shaft for IRC30x, a 10 mm solid shaft for IRC31x and a 12 mm hollow shaft for IRC32x. These are dimensions of the series listed, not of the entire category. Always also compare the insertion length, centring diameter, fixing elements and outlet orientation.

Technical document: LARM: dimensions and variants IRC300–325 (PDF).

Divide your own mounting check into two steps: first verify whether the parts fit dimensionally, then whether the connection will transmit impermissible forces to the bearings during operation. For a solid shaft, assess the coupling; for a hollow shaft, also the reaction support of the body. The cable must have its own strain relief. Mounting selection is continued in Incremental encoder accessories.

The electrical output is not determined by the number of pulses

The documentation for the IRC300–325 series distinguishes push-pull, NPN/PNP open collector and line driver variants with different supply and frequency limits. The designation of the cable or connector outlet does not replace this check. Write down the complete order code and compare the diagram with the specific counter input.

A practical comparison sheet should have separate items for supply, output type, signal level, number of periods, inverted channels and index. For example, a 24V switchboard supply alone does not determine whether the input is ready for HTL or differential RS422. Without verification, do not bridge inverted outputs to ground and do not confuse the signal reference with the shield.

Resolution can limit the usable speed

For N periods per revolution and a permissible channel frequency fmax, the electrical limit is nmax = 60 × fmax / N. Also determine the resulting operating limit according to the mechanics, receiver and any index. For IRC300–325, LARM explicitly points out that the zero pulse is not guaranteed above 100 kHz. This value must not be confused with the higher limit of some A/B outputs.

Technical document: LARM: frequency limits and index Z restriction (PDF).

Model example: checking the required 3 000 rpm

Consider N = 4 096 periods/revolution and an output limit of 200 kHz, as stated in the sheet for the IRC3x5. variant. At 3 000 rpm the result is 204.8 kHz, so the requirement exceeds the electrical limit. The calculated limit is approximately 2 930 rpm; this is not a recommended continuous speed nor guaranteed operation of index Z.

For a limit of 100 kHz, the result is approximately 1 465 rpm. If the application needs the index, check the homing speed and any requirement for Z during normal operation separately. The calculation assumes ideal transmission and contains no design reserve.

Frequently asked questions during commissioning

Why does the reading show double after changing the encoder?

Compare the original and new number of periods and the ×1/×2/×4. mode. A check test is one known shaft revolution and the expected number of increments. Only then verify the conversion via the gearbox.

Does higher resolution ensure a more accurate mechanism?

Higher resolution refines the numerical step. Verify the accuracy of the assembly separately, especially when changing direction and load. Backlash or elastic twisting of the mechanical connection remain part of the result.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.