Phone +420 774 723 123 Cart · 0 · empty

Magnetic Sensors

EMAS SM magnetic door sensors for non-contact monitoring of doors and guards. Choose by design, NO/NC contacts and mounting.

Filters
Found 8 products
−20 % OUR TIP IN STOCK

SMB31LC2-B18, EMAS, magnetic switch / sensor, 2 NC + 1 NO, LED, cable 2 m, Sn 8 mm, IP68

Cat. no.: SMB31LC2-B18

SMB31LC2-B18 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 8 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
24,64 € 30,80 €
excl. VAT · 29,82 € incl. VAT
−20 % OUR TIP IN STOCK

SMB31RC2-B18, EMAS, magnetic switch / sensor, 2 NC + 1 NO, LED, cable 2 m, Sn 8 mm, IP68

Cat. no.: SMB31RC2-B18

SMB31RC2-B18 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 8 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
24,64 € 30,80 €
excl. VAT · 29,81 € incl. VAT
−20 % OUR TIP IN STOCK

SMS21LSZ-S15, EMAS, magnetic switch / sensor, 2 NC, LED, M8, 4 pins, Sn 5 mm, IP68

Cat. no.: SMS21LSZ-S15

SMS21LSZ-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 5 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
24,88 € 31,10 €
excl. VAT · 30,10 € incl. VAT
−20 % OUR TIP IN STOCK

SMS21RSZ-S15, EMAS, magnetic switch / sensor, 2 NC, LED, M8, 4 pins, Sn 5 mm, IP68

Cat. no.: SMS21RSZ-S15

SMS21RSZ-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 5 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
29,26 € 36,57 €
excl. VAT · 35,40 € incl. VAT
−20 % OUR TIP IN STOCK

SMS31LC2-S15, EMAS, magnetic switch / sensor, 2 NC + 1 NO, LED, cable 2 m, Sn 5 mm, IP68

Cat. no.: SMS31LC2-S15

SMS31LC2-S15 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.

In stock 4 ks
29,26 € 36,57 €
excl. VAT · 35,40 € incl. VAT
−20 % OUR TIP IN STOCK

SMB21RSZ-B18, EMAS, magnetic switch / sensor, 2 NC, LED, M8, 4 pins, Sn 8 mm, IP68

Cat. no.: SMB21RSZ-B18

SMB21RSZ-B18 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 8 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
30,80 € 38,50 €
excl. VAT · 37,27 € incl. VAT
−20 % OUR TIP IN STOCK

SMS31RC2-S15, EMAS, magnetic switch / sensor, 2 NC + 1 NO, LED, cable 2 m, Sn 5 mm, IP68

Cat. no.: SMS31RC2-S15

SMS31RC2-S15 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.

In stock 5 or more pcs
30,80 € 38,50 €
excl. VAT · 37,27 € incl. VAT
OUR TIP

SMS21LC2-S15, EMAS, magnetic switch / sensor, 2 NC, LED, cable 2 m, Sn 5 mm, IP68

Cat. no.: SMS21LC2-S15

SMS21LC2-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.

On request
33,64 €
excl. VAT · 40,70 € incl. VAT

Prices include the recycling fee.

Magnetic Sensors

This category contains EMAS SM magnetic door sensors, not universal sensors for pneumatic cylinder slots. The position is evaluated by means of a magnetic counterpart without mechanical pressing of an actuator. Such a solution requires the correct mutual orientation of both parts; the mere presence of a metal object in front of the face is not equivalent to the approach of the designated counterpart.

Contact arrangement and connection

The models offered include SMB31RC2-B18 with contacts 2NC + 1NO, a two-metre cable and a stated sensing distance of 8 mm. SMS21LSZ-S15 has a 2NC, connector M8 with four contacts and a rating of 5 mm. These differences are confirmed by the EMAS SM magnetic door switch manufacturer's overview. Do not regard the distance figure as a permitted mounting gap under all conditions without further documentation.

When replacing, the sensor and counterpart pair specified by the manufacturer must be retained and its geometric and electrical conditions checked. Interchangeability with any magnet does not follow from a similar shape or the same magnetic principle. The exact designation of both parts, the mounting drawing and the wiring diagram take precedence over an approximate comparison of photos.

Read NO and NC together with the diagram

The contact designation must refer to the reference position defined by the manufacturer. It cannot be assumed without verification that the word NC always means "door closed", or that the presence of the magnet corresponds to an active output in the sense of a common PNP sensor. Check the wiring of the individual paths and their state with the counterpart near and away. The contact arrangement is not a current rating.

If the model has LED indication, also assess its power supply and meaning. Illumination is not independent proof of the state of all contacts. Before connecting, check the electrical limits, the usable input and the method of channel evaluation. The M8 connector describes part of the mechanical interface; it does not define a universal pin assignment for all products.

Model example: door gap tolerance

Consider a purely model project for which an operating gap of at most 3.0 mm was determined by separate verification of the specific configuration. The mounting setting is 1.8 mm, the possible change due to the hinges 0.5 mm and the contribution of deflection another 0.4 mm. The largest gap considered is therefore 1.8 + 0.5 + 0.4 = 2.7 mm and the design reserve is 0.3 mm.

These limits are not SMB or SMS parameters. The calculation only shows the addition of geometric tolerances. Lateral offset and rotation may change sensing differently from the gap alone, so they cannot automatically be converted to a single equivalent distance. The real solution must be based on the operating ranges of the designated pair or on guaranteed switch-on and switch-off limits, if these are documented for the given purpose.

Mounting, safety and FAQ

Fasten both parts so that their position is not changed by closing the guard or by cable pull. The test should include slow opening, reclosing and extreme play. Neither the number of contacts, the magnetic principle nor a coded counterpart by themselves assign a PL or SIL level to the whole function. For protective applications, also compare Safety Limit Switches; mechanical alternatives can be found in the category Limit Switches.

Are the stated millimetres a guaranteed safe gap?

Not without verifying the meaning of the figure and the relevant limits in the documentation. The nominal sensing distance is not automatically a guaranteed limit for the whole machine.

Will a door sensor replace mechanical guard locking?

No. Position information is not physical restraint of the door. The need for locking against opening depends on the risk assessment and the duration of the hazard.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.