SMB31LC2-B18, EMAS, magnetic switch / sensor, 2 NC + 1 NO, LED, cable 2 m, Sn 8 mm, IP68
SMB31LC2-B18 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 8 mm. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS SM magnetic door sensors for non-contact monitoring of doors and guards. Choose by design, NO/NC contacts and mounting.
SMB31LC2-B18 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 8 mm. Technical parameters, application and compatibility check.
SMB31RC2-B18 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 8 mm. Technical parameters, application and compatibility check.
SMS21LSZ-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 5 mm. Technical parameters, application and compatibility check.
SMS21RSZ-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 5 mm. Technical parameters, application and compatibility check.
SMS31LC2-S15 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.
SMB21RSZ-B18 EMAS – magnetic switch / sensor, 2 NC, IP68, M8, 4 pins, 8 mm. Technical parameters, application and compatibility check.
SMS31RC2-S15 EMAS – magnetic switch / sensor, 2 NC + 1 NO, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.
SMS21LC2-S15 EMAS – magnetic switch / sensor, 2 NC, IP68, cable 2 m, 5 mm. Technical parameters, application and compatibility check.
Prices include the recycling fee.
This category contains EMAS SM magnetic door sensors, not universal sensors for pneumatic cylinder slots. The position is evaluated by means of a magnetic counterpart without mechanical pressing of an actuator. Such a solution requires the correct mutual orientation of both parts; the mere presence of a metal object in front of the face is not equivalent to the approach of the designated counterpart.
The models offered include SMB31RC2-B18 with contacts 2NC + 1NO, a two-metre cable and a stated sensing distance of 8 mm. SMS21LSZ-S15 has a 2NC, connector M8 with four contacts and a rating of 5 mm. These differences are confirmed by the EMAS SM magnetic door switch manufacturer's overview. Do not regard the distance figure as a permitted mounting gap under all conditions without further documentation.
When replacing, the sensor and counterpart pair specified by the manufacturer must be retained and its geometric and electrical conditions checked. Interchangeability with any magnet does not follow from a similar shape or the same magnetic principle. The exact designation of both parts, the mounting drawing and the wiring diagram take precedence over an approximate comparison of photos.
The contact designation must refer to the reference position defined by the manufacturer. It cannot be assumed without verification that the word NC always means "door closed", or that the presence of the magnet corresponds to an active output in the sense of a common PNP sensor. Check the wiring of the individual paths and their state with the counterpart near and away. The contact arrangement is not a current rating.
If the model has LED indication, also assess its power supply and meaning. Illumination is not independent proof of the state of all contacts. Before connecting, check the electrical limits, the usable input and the method of channel evaluation. The M8 connector describes part of the mechanical interface; it does not define a universal pin assignment for all products.
Consider a purely model project for which an operating gap of at most 3.0 mm was determined by separate verification of the specific configuration. The mounting setting is 1.8 mm, the possible change due to the hinges 0.5 mm and the contribution of deflection another 0.4 mm. The largest gap considered is therefore 1.8 + 0.5 + 0.4 = 2.7 mm and the design reserve is 0.3 mm.
These limits are not SMB or SMS parameters. The calculation only shows the addition of geometric tolerances. Lateral offset and rotation may change sensing differently from the gap alone, so they cannot automatically be converted to a single equivalent distance. The real solution must be based on the operating ranges of the designated pair or on guaranteed switch-on and switch-off limits, if these are documented for the given purpose.
Fasten both parts so that their position is not changed by closing the guard or by cable pull. The test should include slow opening, reclosing and extreme play. Neither the number of contacts, the magnetic principle nor a coded counterpart by themselves assign a PL or SIL level to the whole function. For protective applications, also compare Safety Limit Switches; mechanical alternatives can be found in the category Limit Switches.
Not without verifying the meaning of the figure and the relevant limits in the documentation. The nominal sensing distance is not automatically a guaranteed limit for the whole machine.
No. Position information is not physical restraint of the door. The need for locking against opening depends on the risk assessment and the duration of the hazard.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.