LED strip RGBW-24, TECHNOLINE, four-colour LED strip RGBW, 24VDC
LED strip RGBW-24 TECHNOLINE: four-colour 24VDC LED strip - red, green, blue and white 4000K. Common cathode, 60 LED / m, SMD5050, IP20.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
RGBW 24 V DC LED strips for light signalling of machine status or lighting. Choose by length, colours and control (common cathode).
LED strip RGBW-24 TECHNOLINE: four-colour 24VDC LED strip - red, green, blue and white 4000K. Common cathode, 60 LED / m, SMD5050, IP20.
Prices include the recycling fee.
When selecting LED strip it is not enough to determine color and length. For a functional setup, the power supply voltage, control method, current load, and common output must be agreed upon. In industrial applications, it also decides whether the light should indicate the machine's status or actually illuminate the working area.
In this category you can find LED strip RGBW-24. Its product data sheet specifies 24 V DC, common cathode, 60 LEDs per meter, and a white component of 4000 K. These details apply to the specified product; they cannot be automatically applied to other LED strips or their replacements.
RGB stands for red, green, and blue light components. RGBW adds an additional white component. If each component is to be controlled individually, this must correspond to the number and implementation of output channels on the regulator. The term RGBW alone does not guarantee addressable control of individual LEDs or a specific communication protocol.
For a common cathode, the cathode outputs of individual color branches are connected. For a common anode, the anodes are connected instead. This is electrically different, so a regulator for one type cannot be automatically used for another. The principle and relationship to the type of output driver are explained. technical training Texas Instruments on selection of RGB LED driver.
Therefore, do not replace the joint cathode belt with a joint anode according to the same voltage and colour only. It is not about a difference that can be resolved simply by swapping channel names in the program. Before ordering, compare the strip layout and control device schema, the meaning of the weights, and the allowed current for each channel.
First determine whether the wattage figure is given per meter, for the entire piece, or for a specific combination of color channels. Without this distinction, it cannot be reliably calculated for multiple meters. If the documentation only mentions W without a clear relationship to length and mode, request clarification.
For an illustrative, independent example, let us consider the input: 2 m tape, explicitly defined power input 12 W / m at the desired mode and voltage 24 V DC. Then P = 2 × 12 = 24 W and I = 24 / 24 = 1 AThe numbers are only a model calculation, not the product parameters RGBW-24.
The result determines the default strip take-up. For the final design, add any additional powered elements and respect the allowed load from the source at the actual temperature. For a more detailed explanation of CV and CC, performance reserves, and voltage drop, see signalling controls and LED strip guides.
For status signalling, pre-write the meaning of colors, the status when the device is turned on, and how to distinguish faults from normal operation. Verify clarity at the point of service. For working lighting, the color 4000 K and the number of LEDs per meter do not indicate how much light will fall on the work surface or how colors of objects will be presented. For such a design, additional lighting technical data and workplace arrangement assessment are needed.
The environment must also correspond to the declared performance. For the RGBW-24 strip, IP20 is stated on the product data sheet; this information cannot be taken as proof of the suitability of an unprotected installation in a wet environment. The safety of the finished solution must be assessed, including the cover and connection.
To complete the lineup, go to Power suppliesUnclear compatibility through Technical support with the exact marking of the two components connected.
No. In addition to the voltage, the common cathode or anode, the control mode and current capacity of the outputs shall be in particular appropriate.
No. The length of the package and the permissible arrangement of the power supply are different data. They decide the assembly instructions of the particular tape.
No. The density of LED is the installation figure. Individual addressing must be explicitly stated in the documentation; the number of LED is not derived from the number of LED.
This text is a guide for selection, not a universal wiring instruction. Parameters and installation must be verified according to the specific order variant. Electrical installations must be carried out by a professionally qualified person.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.