Phone +420 774 723 123 Cart · 0 · empty

Insulated Crimp Cable Lugs

ONKA insulated crimp cable lugs for connecting conductors to screw terminals. Choose by conductor cross-section and stud diameter.

Filters
Found 8 products
IN STOCK

ONKA-8051-10, ONKA, crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 10ks

Cat. no.: ONKA-8051-10

ONKA-8051-10 ONKA – crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 10ks. Key data: 1.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
0,74 €
excl. VAT · 0,89 € incl. VAT
IN STOCK

ONKA-8052-10, ONKA, crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 6mm, 10ks

Cat. no.: ONKA-8052-10

ONKA-8052-10 ONKA – crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 6mm, 10ks. Key data: 1.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
0,78 €
excl. VAT · 0,94 € incl. VAT
OUR TIP IN STOCK

ONKA-8087-10, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 10ks

Cat. no.: ONKA-8087-10

ONKA-8087-10 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 10ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
0,78 €
excl. VAT · 0,94 € incl. VAT
IN STOCK

ONKA-8089-10, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 10ks

Cat. no.: ONKA-8089-10

ONKA-8089-10 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 10ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
0,90 €
excl. VAT · 1,09 € incl. VAT
IN STOCK

ONKA-8051-200, ONKA, crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 200ks

Cat. no.: ONKA-8051-200

ONKA-8051-200 ONKA – crimp cable lug, insulated, for conductor cross-section 0.5-1.5mm², hole 5mm, 200ks. Key data: 1.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
9,37 €
excl. VAT · 11,34 € incl. VAT
IN STOCK

ONKA-8087-200, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 200ks

Cat. no.: ONKA-8087-200

ONKA-8087-200 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 5mm, 200ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
10,27 €
excl. VAT · 12,43 € incl. VAT
IN STOCK

ONKA-8052-200, ONKA, insulated crimp cable lug M6 for conductors 0.5–1.5 mm², pack of 200 pcs

Cat. no.: ONKA-8052-200

ONKA-8052-200 ONKA – insulated crimp cable lug M6 for conductors 0.5–1.5 mm², pack of 200 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
12,65 €
excl. VAT · 15,30 € incl. VAT
IN STOCK

ONKA-8089-200, ONKA, crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 200ks

Cat. no.: ONKA-8089-200

ONKA-8089-200 ONKA – crimp cable lug, insulated, for conductor cross-section 1.5-2.5mm², hole 6mm, 200ks. Key data: 2.5 mm². Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
12,73 €
excl. VAT · 15,40 € incl. VAT

Prices include the recycling fee.

Insulated crimp cable lugs

An insulated crimp cable lug terminates a conductor with a contact surface with a hole for a screw connection. It is suitable where the connection point is designed for this type of termination. It is not a substitute for a ferrule in any terminal: a ferrule creates a termination in the direction of the conductor, while a lug needs a matching seating surface and space around the screw. For a different connection method, continue to the category of crimp cable ferrules; related material can be found in the overview of electrical consumables.

Two independent sizes of one lug

The range includes, for example, designations ONKA-8051 and ONKA-8052 for the 0.5–1.5 mm² range and ONKA-8087 or ONKA-8089 for 1.5–2.5 mm². These groups are also listed in the ONKA manufacturer overview of insulated lugs. The suffix of the commercial item may distinguish the packaging, not a new size of the contact part.

When selecting, first determine the conductor and only then the connecting screw. The hole of the lug is not a conductor cross-section figure. Two lugs with the same hole may have a different crimp section, and two lugs for the same conductor may fit different connection points. Besides the hole diameter, also assess the ring width, the overall length and the space for the insulated neck.

Crimping and checking the finished joint

The tool must be designed for the given type of insulated terminal and its size group. Ferrule jaws are not automatically suitable for cable lugs. The distinction of working profiles and usable terminals can be seen in the KNIPEX crimping pliers documentation; the specific combination must be assessed for the lug used.

In the work procedure, specify the stripping length, the position of the terminal in the tool and the inspection of the result according to the relevant instructions. The inspection includes completeness of the strands, the position of the insulation and absence of damage to the contact surface. Additional soldering or a stronger squeeze with other pliers is not a universal fix for an incorrectly made crimped joint. In series work, it makes sense to check the first sample before processing the whole batch.

What to check at the connection point

The tightening torque is determined by the documentation of the connected equipment and the specific joint, not just by the lug size. Any stacking of several lugs, the orientation of the supply and the mechanical stress are assessed individually in the same way. The cable should be routed so that its normal movement does not pull on the contact joint. To organise a fixed route, you can use cable ties and their fixing accessories according to the installation conditions.

Model selection example

Imagine two connection points with the same nominal screw M5. The first has a 1 mm² conductor, the second 2.5 mm². The same screw does not lead to the same lug: first the correct crimp group is found for each conductor, then a suitable hole and contact geometry. The designation M5 here describes our own model brief, not the universal compatibility of a specific catalogue code.

The bill of materials will therefore contain two items, even if the number of connection points is the same. Before ordering a larger pack, it is advisable to compare a sample with the device dimensionally, especially if narrow terminals lie side by side or there is a protective cover around the joint.

FAQ

Is it enough to go by the insulation colour when replacing?

No. Check the cross-section designation and the complete dimensional description. The colour does not prove the same hole, length or suitability for a specific conductor.

Does the cross-section stated for the lug alone determine the current of the joint?

No. The entire electrical and mechanical joint is assessed, including the conductor, the connection point, temperature conditions and workmanship. A universal current limit cannot be derived from the range of the crimp section.

Cookies on this website