Phone +420 774 723 123 Cart · 0 · empty

MN3 Metal Limit Switches

EMAS MN3 metal miniature limit switches with changeover contact. Choose by actuating element.

Filters
Found 3 products
−8 % OUR TIP IN STOCK

MN3PUM9, EMAS, miniature limit switch, MN3, 1 CO, IP65

Cat. no.: MN3PUM9

MN3PUM9 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.

In stock 5 or more pcs
8,85 € 9,62 €
excl. VAT · 10,71 € incl. VAT
−15 % OUR TIP IN STOCK

MN3MUM8, EMAS, miniature limit switch, MN3, 1 CO, IP65

Cat. no.: MN3MUM8

MN3MUM8 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.

In stock 5 or more pcs
10,06 € 11,83 €
excl. VAT · 12,17 € incl. VAT
OUR TIP IN STOCK

MN3MUM3, EMAS, miniature limit switch, MN3, 1 CO, IP65

Cat. no.: MN3MUM3

MN3MUM3 EMAS – miniature limit switch, MN3, 1 CO, IP65. Technical parameters, application and compatibility check.

In stock 5 or more pcs
11,83 €
excl. VAT · 14,32 € incl. VAT

Prices include the recycling fee.

Metal Limit Switches MN3

Select a miniature metal switch MN3 according to both the installation location and the electrical task. A small housing can solve a space problem, but does not by itself determine the suitability of the contacts for the given load. When replacing, therefore, separate the mechanical comparison from the electrical one and only then assess whether the assembly is usable in the required environment.

What one changeover contact means

The public range includes MN3MUM3. EMAS sheet MN3MUM3 states a metal plunger actuator with a roller and contact 1CO. The designation represents one changeover contact; do not regard it as two separate, electrically independent circuits.

Before ordering, draw the required output states and compare them with the product diagram. Decide what information you need in the rest position and when pressed. For a service replacement, use the terminal markings of the actual model. The position of contacts or terminals in a photo is not a reliable basis for their assignment.

Contact load and connection quality

Base the electrical selection on the voltage, type of load and switching conditions. OMRON in its guidelines for basic switches points out the difference between steady-state and inrush current. A single maximum figure therefore cannot be used as a universal current rating of the assembly.

In the connection plan, record the conductor cross-section, termination, relevant mounting requirements and method of mechanical strain relief. Space for service inspection is also important. If the cable is already taut after mounting, normal handling during maintenance can transfer force to the connection. Therefore draw the route including the last fastening point.

Author's example: loss at a connection

Consider a model electrical joint with a resistance of 0.05 Ω. At a current of 2 A, a power loss of P = I²R = 2² × 0.05 = 0.20 W occurs. At a current of 4 A and the same resistance, the result is 0.80 W. Doubling the current therefore causes four times the loss.

This is our own calculation of an ideal joint, not the contact resistance, permitted current or temperature rise of MN3MUM3. The temperature cannot be determined from it without further data. The example shows why, when assessing a connection, one should not only check whether the circuit is currently conducting, but also the quality and stability of the joint.

If the model resistance increased to 0.10 Ω at an unchanged current of 2 A, the loss would rise to 0.40 W. Such a comparison helps explain the importance of correct conductor termination without setting a diagnostic limit for a specific product.

Approach mechanics and service

For a plunger actuator with a roller, prepare a drawing of the cam and observe the contact point throughout the cycle. The mounting report should include the maximum depression reached and the return to the initial state. Evaluate against the permitted range from the instructions, not according to whether the actuator can still be pressed by hand.

A common mistake is to solve a lack of space with a smaller switch and leave the original approach unchecked. The new roller position can change the course of actuation even with the same housing position relative to the frame.

Does a metal housing guarantee safety use?

No. Neither a safety task nor a PL or SIL level can be derived from the material or size of the housing.

When should the plastic variant be compared?

If it suits the mechanics and environment, study Plastic Limit Switches MN1. Other designs and accessories can be found in the overview Miniature Limit Switches.